Sign In | Join Free | My infospaceinc.com
infospaceinc.com
Products
Search by Category
Home > Recycling >

High Precision 4-20mA Magnetic Flow Meter Transmitter Electromagnetic Digital Flow Meter

Categories Electromagnetic Flow Meter
Brand Name: INSTE
Model Number: ISTLDG
Place of Origin: Jiangsu, China
MOQ: 1 set
Price: USD200-800/ set
Payment Terms: T/T, Western Union
Supply Ability: 100 sets per day
Delivery Time: 2-3 word days
Packaging Details: wooden package
Caliber: DN80
Power Supply: AC220V,DC24V, 3.6V
Display: Instantaneous flow, total flow, flow velocity
Structure Type: Integrate or Remote
Pressure: 0.6Mpa-10Mpa
Accuracy: ±0.5% of reading
Fluid Temperature: -20°C~120°C
Ambient Temperature: -20℃~60℃
Environment Temperature: -10℃~+60℃
Output: 4-20mA
Communication: RS485 MODBUS RTU, HART, GPRS
Electrode: SS316L, Hastelloy B, Hastelloy C, Titannium, Tantanlum, Platinum-iridium
Flange Standard: DIN, ANSI, JIS
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

High Precision 4-20mA Magnetic Flow Meter Transmitter Electromagnetic Digital Flow Meter


DN80 Smart Electromagnetic Flow Meter: High-Precision ±0.5% Accuracy with 4-20mA Output


product introduction


Our DN80 Electromagnetic Flow Meter is a high-performance, industrial-grade solution designed for precise liquid measurement. Built with advanced electromagnetic induction technology, this magmeter provides exceptional reliability for water treatment, chemical processing.


1. High-Precision Measurement (±0.5% Accuracy)
Accuracy is critical in industrial automation. This electromagnetic flow meter features a sophisticated signal processing algorithm that ensures a stable measurement with an accuracy of ±0.5% of reading.


Reliable Data: Minimized drift and high repeatability for billing and process control.

Wide Range: Maintains precision across a broad flow velocity range, ensuring every drop is accounted for.


2. Standard DN80 (3-Inch) Robust Design
The DN80 (80mm) size is the industry standard for medium-sized pipelines.


Full Bore Construction: No moving parts inside the pipe, meaning zero pressure loss and no risk of mechanical wear.

Corrosion Resistance: Available with PTFE or Rubber linings and SS316L or Hastelloy electrodes to handle everything from tap water to corrosive acids.


3. Seamless Integration (4-20mA & Smart Output)
Designed for the modern smart factory, our electromagnetic flow transmitter offers versatile connectivity:


Industry Standard 4-20mA Output: Easy integration with PLC, DCS, and SCADA systems for real-time monitoring.

Pulse & Digital Communication: Supports Pulse output for totalizer functions and RS485 MODBUS / HART for remote configuration and diagnostics.


Technical Specifications


nameHigh Precision 4-20mA Magnetic Flow Meter Transmitter Electromagnetic Digital Flow Meter
Nominal DiameterDN80 (3 Inch)
Accuracy±0.5% of reading
Output Signal4-20mA
CommunicationRS485 Modbus RTU / HART
Power SupplyAC220V / DC24V / 3.6V Battery Operated
Lining MaterialPTFE / Neoprene / F46
Electrode MaterialSS316L / Hastelloy C / Titanium / Tantalum
Protection ClassIP65 (Standard) / IP68 (Waterproof)

Setting Parameters in Menu

There are 54 parameters of L_MagB, user can set every parameter. The List of Parameters is shown below:

Setting Parameters in Menu

CodeParameter wordsSetting WayGradesRange
1LanguageSelect2English
2Comm AddresSet count20~99
3Baud RateSelect2300~38400
4Snsr SizeSelect23~3000
5Flow UnitSelect2

L/h,L/m,L/s,m3/h,

m3/m,m3/s

6Flow RangeSet count20~99999
7Flow RspnsSelect21~50
8Flow DirectSelect2Plus/ Reverse
9Flow ZeroSet count20~±9999
10Flow CutoffSet count20~599.99%
11Cutoff EnaSelect2Enable/Disable
12Total UnitSelect2

0.001m3~1m3 ,

0.001L~1L,


13SegmaN EnaSelect2Enable/Disable
14Analog TypeSelect20~10mA /4~20mA
15Pulse TypeSelect2Freque / Pulse
16Pulse FactSelect2

0.001m3~1m3 ,

0.001L~1L,

17Freque MaxSelect21~ 5999 HZ
18Mtsnsr EnaSelect2Enable/Disable
19Mtsnsr TripSet count259999 %
20Alm Hi EnaSelect2Enable/Disable
21Alm Hi ValSet count2000.0~ 599.99 %
22Alm Lo EnaSelect2Enable/Disable
23Alm Lo ValSet count2000.0~599.99 %
24Sys Alm EnaSelect2Enable/Disable
25Clr Sum KeySet count30~99999
26Snsr Code1User set4Finished Y M
27Snsr Code2User set4Product number
28Field TypeSelect4Type1,2,3
29Sensor FactSet count40.0000~5.9999
30Line CRC EnaSelect2Enable/Disable
31Lineary CRC1User set4Set Velocity
32Lineary Fact 1User set40.0000~1.9999
33Lineary CRC2User set4Set Velocity
34Lineary Fact 2User set40.0000~1.9999
35Lineary CRC3User set4Set Velocity
36Lineary Fact 3User set40.0000~1.9999
37Lineary CRC4User set4Set Velocity
38Lineary Fact4User set40.0000~1.9999
39FwdTotal LoCorrectable500000~99999
40FwdTotal HiCorrectable500000~9999
41RevTotal LoCorrectable500000~99999
42RevTotal HiCorrectable500000~9999
43PlsntLmtEnaSelect3Enable/Disable
44PlsntLmtValSelect30.010~0.800m/s
45Plsnt DelaySelect3400~2500ms
46Pass Word 1User correct500000~99999
47Pass Word 2User correct500000~99999
48Pass Word 3User correct500000~99999
49Pass Word 4User correct500000~99999
50Analog ZeroSet count50.0000~1.9999
51Anlg RangeSet count50.0000~3.9999
52Meter FactSet count50.0000~5.9999
53MeterCode 1Factory set6Finished Y /M
54MeterCode 2Factory set6Product Serial No

Parameters of converters can decide the running status, process and output ways as well as state of output. Correct option and setting of parameters can keep the converters running optimally and get higher accuracies of output bother in display and in measurement.

There are 6 grades of passwords for setting parameters function. Grades 1 to grade 5 of passwords are for users and grade 6 of password is for manufacturer. Users can reset their passwords of grades 1~4 in grade 5.

Users can check converters parameters in any grade of password. However, if users want to change parameters pf converters, deferent grade of parameters have to be used by the users.

Grade 1 of password (set by manufacturer as 00521): users can only read parameter.

Grade 2 of password (set by manufacturer as 03210): users can change 1~24 parameters.

Grade 3 of password (set by manufacturer as 06108): users can change 1~25parameters.

Grade 4 of password (set by manufacturer as 07206): users can change 1~38parameters.

Grade 5 of password (Fixed): users can change 1~52 parameters.

Password Grade 5 can be set by skilled users. Grade 4 is mainly used for resetting total volume in password. Grades 1~3 can be set by any one who can be chosen by users.


Buy High Precision 4-20mA Magnetic Flow Meter Transmitter Electromagnetic Digital Flow Meter at wholesale prices
Send your message to this supplier
 
*From:
*To: Nanjing Inste Automation Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0