| Measurement Principle | Velocity or Acceleration |
| Output Signal | 4-20 mA loop powered |
| Output Calibration Options | Peak, True Peak, RMS (for broadband); Peak, RMS (for frequency
banded) |
| Dual Output Options | Temperature and 4-20 mA vibration; Dynamic (Acceleration or
Velocity) and 4-20 mA vibration |
| Frequency Banded Transducers | - Low Frequency (e.g., PC420VP-10-B3041): 3 Hz to 40 Hz (180 RPM to 2400 RPM) for balance and alignment
diagnostics.
- High Frequency (e.g., PC420AR-10-3223): 300 Hz to 2,000 Hz (18,000 RPM to 120,000 RPM) for pump
cavitation.
|
| Hazardous Area Installations | - Intrinsically Safe (IS): CSA Class 1, Div 1, GRPS A, B, C, D T3C; ATEX EEx ia IIC T3.
Models end in -IS.
- Explosion Proof (EX): CSA Class 1, Div 1, 2 GRPS A, B, C, D; Class 2, Div 1, 2 GRPS E,
F, G; Class 3, Div 1, 2 T3C; ATEX EEx d IIC T3, EEx nA IIC T3.
Models end in -EX.
|
| Model Number Structure | PC42[Exit]-[Range]-[Options] or PCC42[Exit]-[Range]-[Options] |
| Exit Types | Top exit (PC420), Side exit (PC421, PC423), Side exit with
temperature sensor (PC425, PC427) |
| Ranges | -05, -10, -20, -30, -50 (specific units for velocity or
acceleration) |
| Optional Configurations | DA (Dynamic Acceleration), DV (Dynamic Velocity), IS (Intrinsically
Safe), EX (Explosion Proof) |
| Cabling / Connections | Integral cable (standard 16'), R6, M12-4, J9T2A, J10, J9T4, J9T4A,
J95 (specific to model) |
| Example Model: PC420VP-10 | Velocity, Peak calibrated output, 1.0 ips full-scale range. |
| Example Model: PC420VP-10-DA | Velocity, Peak calibrated output, 1.0 ips full-scale range, with
additional Dynamic Acceleration output (100 mV/g). |
| Example Model: PC420VP-10-IS | Velocity, Peak calibrated output, 1.0 ips full-scale range,
Intrinsically Safe rated. |
| Example Model: PC420VP-10-B3041 | Velocity, Peak calibrated, 1.0 ips full-scale, band-limited 3-40
Hz. |
| Example Model: PC420AR-10-B3223 | Acceleration, RMS calibrated, 10 g full-scale, band-limited
300-2,000 Hz. |