Sign In | Join Free | My infospaceinc.com
infospaceinc.com
Products
Search by Category
Home > Hair Care >

Lithium Ion Battery Pack Comprehensive Tester 200V 100A Charge 400A Discharge

Categories Battery Comprehensive Tester
Brand Name: ACEY
Model Number: ACEY-BIT200-100A400A
Certification: CE
Place of Origin: China
MOQ: 1 Set
Price: USD 2280~21980/Set
Payment Terms: T/T,PayPal,L/C,Western Union,MoneyGram
Supply Ability: 200 Sets/Month
Delivery Time: 7~35 Days
Packaging Details: Plywood Case
Warranty: 1 Year Warranty with Lifetime Support
After-sales Service: 24/7 Technical Support
Voltage Range: 0~200V
Charging Current: 0~100A
Discharging Current: 0~400A
Current Resolution: 0.001A
Current Accuracy: ±(0.1% RD + 0.1 FS)
Input Power Supply: AC 200~240V 50/60HZ
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Lithium Ion Battery Pack Comprehensive Tester 200V 100A Charge 400A Discharge

Lithium Ion Battery Pack Comprehensive Tester 200V 100A Charge 400A Discharge


Product Description

ACEY-BIT200-100A400A battery charge discharge test equipment is used for comprehensive performance testing of lithium-ion battery packs for energy storage modules, electric vehicles, electric scooters, AGVs, and garden tools. It supports all series of power batteries with CH+ / P+ / CH− / P− terminals, and is suitable for both semi-finished and finished product testing during production. The equipment can also be used as an electronic load for long-duration current draw testing of battery packs.


Main Technical Parameter

VoltageTotal Voltage0–200 V0.1 mV±0.1% RD + 0.1% FS
Internal ResistanceAC Internal Resistance0–4000 mΩ0.001 mΩ±0.1% RD + 0.1% FS
Charge DC Internal Resistance0–4000 mΩ0.001 mΩ±0.1% RD + 0.1% FS
Discharge DC Internal Resistance0–4000 mΩ0.001 mΩ±0.1% RD + 0.1% FS
ChargingStatic Voltage0–200 V0.1 mV±0.1% RD + 0.1% FS
Charge Current0–100 A0.001 A±0.1% RD + 0.1% FS
Charge Time3 s
Charge Voltage0–200 V0.1 mV±0.1% RD + 0.1% FS
Charge Delay0–3 s1 ms±0.1% RD + 0.1% FS
Charging Power12 kW
DischargingStatic Voltage0–200 V0.1 mV±0.1% RD + 0.1% FS
Loaded Voltage0–200 V0.1 mV±0.1% RD + 0.1% FS
Discharge Current0–400 A0.001 A±0.1% RD + 0.1% FS
Discharge Time (400 A)3 s
Over-current Delay0–3 s1 ms±0.1% RD + 0.1% FS
Discharging Power80 kW
Short CircuitShort-circuit Time0–2000 μs1 μs±0.1% RD + 0.1% FS
ResistanceNTC0–100 kΩ0.001 kΩ±0.1% RD + 0.1% FS
Identification Resistor0–100 kΩ0.001 kΩ±0.1% RD + 0.1% FS

Test Items

No.Test FunctionDescription
1VoltageVoltage is measured twice: first as no-load voltage, and again after all tests are completed, especially after short-circuit protection testing, to verify battery condition. The second voltage is typically slightly lower than the first.
2Internal ResistanceMeasures the battery’s AC internal resistance at 1000 Hz.
3Charge Over-current Protection CurrentVerifies whether the battery has automatic protection when charge current is excessive. This is critical to prevent damage to the BMS. If no protection exists, continuous charge current is selected instead.
4Charge Over-current Protection DelaySets a current value and measures the time from current generation to BMS protection activation.
5Continuous Charge CurrentFor batteries without charge over-current protection, the charge current is usually set equal to the charger current.
6Continuous Charge Voltage MonitoringDuring continuous charging, upper and lower voltage limits can be set to determine whether the battery voltage exceeds the allowable range.
7Discharge Over-current Protection CurrentWhen discharge current exceeds a set value, protection is triggered, typically according to datasheet specifications.
8Discharge Over-current Protection DelaySets a current value and measures the time from current generation to BMS protection activation.
9Continuous Discharge CurrentRepresents the normal operating discharge current. Abnormal BMS conditions may cause inability to sustain discharge.
10Continuous Discharge VoltageDuring continuous discharge, voltage upper and lower limits can be set to monitor abnormal voltage conditions.
11Short-circuit Protection TimeMeasures the BMS response time when the battery terminals are momentarily shorted. Faster response (typically <1000 μs) provides better protection. Excessive short-circuit time may indicate high loop resistance and requires analysis.
12Cell Voltage (Optional)Dynamic monitoring of individual cell voltage during charge and discharge.
13Charge Voltage RiseCompares end-of-charge voltage with static voltage to determine voltage rise.
14Discharge Voltage DropCompares end-of-discharge voltage with initial voltage to determine voltage drop.
15Charge DC Internal ResistanceCalculated by dividing the voltage rise after charging by the set charge current.
16Discharge DC Internal ResistanceCalculated by dividing the voltage drop after discharging by the set discharge current.
17Identification ResistanceTests ID and NTC resistance values.
18Secondary Discharge Over-current Protection CurrentSecondary protection triggered when discharge current exceeds a preset value, typically per datasheet requirements.
19Secondary Discharge Over-current Protection TimeMeasures the protection response time from current generation to BMS cutoff.
20Communication Test (Optional)Supports RS485, RS232, CAN, and other communication interfaces.
21Insulation & Withstand Voltage (Optional)Insulation resistance and dielectric withstand voltage testing.

Product Display


Buy Lithium Ion Battery Pack Comprehensive Tester 200V 100A Charge 400A Discharge at wholesale prices
Send your message to this supplier
 
*From:
*To: Xiamen Acey New Energy Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0