Schneider BMXNOM0200 Modicon X80 Communication Module

Categories Schneider Modicon X80 Communication Modules
Model Number: BMXNOM0200
Ledindicators: Status, Communication, Power
Brand Name: Schneider Electric
Firmwareupgrade: Supported via Ethernet or USB
Delivery Time: 7-14 Days
Producttype: Communication Module
Dimensions: varies by model (approx. 100mm x 50mm x 75mm)
Supply Ability: 10 Units per Month
Compatibleseries: Modicon X80 PLCs
Operatingtemperaturerange: -20°C to 60°C
Packaging Details: Anti-static Bag + Carton Box + Foam Protection
Powersupply: 24 V DC
Datatransferrate: Up to 100 Mbps (Ethernet models)
Place of Origin: USA
Productname: Schneider Modicon X80 Communication Modules
MOQ: 1 unit
Weight: Approx. 150-200 grams
Interfacetype: Ethernet / Serial / CAN
Price: USD 150 - 250 / Unit
Application: Industrial Automation, Process Control
Mountingtype: DIN Rail
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Schneider BMXNOM0200 Modicon X80 Communication Module

Product Overview

The Schneider BMXNOM0200 is a Modicon X80 serial communication module providing two configurable RS-232 or RS-485 communication ports. It supports Modbus communication and character-mode data exchange.

The module is used in Modicon M340 and compatible X80 systems that need to communicate with serial devices such as drives, energy meters, barcode readers, weighing equipment, printers, protocol converters and legacy controllers.

Each application must be checked for the correct electrical interface, baud rate, parity, data format, Modbus addressing and character-mode framing. The BMXNOM0200 is not an Ethernet communication module.

Main Features

  • Exact commercial reference: BMXNOM0200
  • Modicon X80 serial communication module
  • Two configurable serial communication ports
  • RS-232 communication support
  • RS-485 communication support
  • Modbus communication mode
  • Character communication mode
  • Suitable for point-to-point and multidrop serial architectures
  • Compatible with supported M340 and X80 rack systems
  • Configured through EcoStruxure Control Expert
  • Older projects may use Unity Pro
  • Port mode and protocol settings are configured independently
  • Terminal block, cable and pinout must be verified
  • Firmware compatibility must be checked before replacement

Technical Specifications

ModelBMXNOM0200
SeriesModicon X80
Product TypeSerial Link Communication Module
Platform ScopeModicon M340 and compatible X80 architectures
Number of Serial Ports2
Electrical InterfacesRS-232 or RS-485 configuration
Communication ModesModbus and Character Mode
Network ArchitecturePoint-to-point or compatible multidrop serial networks
Port ConfigurationVerify interface, baud rate, parity, data bits and stop bits
Modbus ConfigurationVerify master or slave role, address and timing requirements
Character ModeVerify start, end and framing characters against the connected device
Rack InstallationCompatible X80 rack slot
Engineering SoftwareEcoStruxure Control Expert
Legacy Engineering EnvironmentOlder applications may use Unity Pro
FirmwareConfirm the installed revision and project compatibility
Terminal and CableConfirm terminal block, connector, pinout, shielding and cable type
Supply StatusRegional availability varies; confirm before quotation

Compatible System and Applications

The BMXNOM0200 is suitable for serial communication with Modbus drives, motor controllers, meters, weighing systems, barcode scanners, printers, protocol converters and legacy automation equipment.

RS-485 is commonly used for compatible multidrop Modbus networks, while RS-232 may be used for shorter point-to-point connections. The actual interface and topology must match the connected device.

Character mode can be used for devices that exchange custom ASCII or binary data rather than standard Modbus messages. Message framing and application logic must be restored from the original Control Expert project.

Maintenance and Replacement Notes

Verify the complete BMXNOM0200 reference and the exact rack-slot configuration before replacement.

Record both port configurations, including RS-232 or RS-485 mode, baud rate, parity, stop bits, Modbus address, master or slave role and character-mode framing.

The existing cable, terminal block and connector pinout must be checked. Incorrect RS-232 or RS-485 wiring can prevent communication or damage connected interfaces.

After replacement, test each port independently and verify communication with every connected serial device.

Related Models

Related communication products include BMXNOC0401 for EtherNet/IP and Modbus TCP, BMXNOE0100 for standard Modbus TCP Ethernet communication and BMXNOE0110 for FactoryCast Ethernet functions.

BMXNOR0200H is an RTU and telemetry-oriented communication module with an H harsh-environment suffix and should be handled as a separate specialized product.

Inquiry and Supply Notes

Please provide the complete module reference, CPU and rack models, slot position, firmware, port-by-port RS-232 or RS-485 configuration, baud rate, Modbus addresses, connected-device list and cable information.

Terminal-block inclusion, connector condition, firmware compatibility, port testing, product condition, regional availability and delivery time must be confirmed before quotation.

Buy Schneider BMXNOM0200 Modicon X80 Communication Module at wholesale prices
Send your message to this supplier
 
*From:
*To: Dengfeng (XinXing) Trading Co., Limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0