| Sign In | Join Free | My infospaceinc.com |
|
All isolated rtd reference junction fbm202 thermocouple input module wholesalers & isolated rtd reference junction fbm202 thermocouple input module manufacturers come from members. We doesn't provide isolated rtd reference junction fbm202 thermocouple input module products or service, please contact them directly and verify their companies info carefully.
| Total 19 products from isolated rtd reference junction fbm202 thermocouple input module Manufactures & Suppliers |
|
|
|
Brand Name:FOXBORO Model Number:FBM202 Place of Origin:America ... one dedicated RTD reference junction channel for terminal temperature compensation. Each channel supports standard thermocouple types with burnout detection and sigma-delta conversion for high accuracy. Designed for harsh industrial environments, it |
Sumset International Trading Co.,Ltd
Fujian |
|
|
Brand Name:FOXBORO Model Number:FBM202 P0926EQ Place of Origin:USA ...FBM202 Thermocouple/mV Input module features eight thermocouple input channels and one isolated RTD reference junction compensation channel for terminal temperature sensing. Each channel accepts standard thermocouples for various temperature ranges and provides thermocouple burnout detection (upscale). All inputs are galvanically isolated from other channels and ground. This module performs signal conversion to interface electrical input |
AMIKON LIMITED
Fujian |
|
|
Brand Name:Foxboro Model Number:FBM202 Place of Origin:FBM202 RH926EQ Foxboro Thermocouple/mV Input Module FBM202 RH926EQ Foxboro Thermocouple/mV Input Module The FBM202 Thermocouple/mV Input contains eight thermocouple input channels, and one isolated RTD reference junction compensation channel. OVERVIEW The FBM202 Thermocouple/mV Input contains eight thermocouple input channels, and one isolated RTD reference junction compensation channel (for terminal temperature sensing). Each thermocouple/mV channel accepts standard thermocouples... |
Xiamen ZhiCheng Automation Technology Co., Ltd
Guangdong |
|
|
Brand Name:General Electric Model Number:IC200ALG266 Place of Origin:USA ...RTD/Thermocouple Input Module Product Description The IC200ALG266 is a genuine GE Fanuc VersaMax analog input module that accepts eight universal temperature sensors--RTD (Pt100/Pt1000) or thermocouple (Types J, K, T, E, N, S, R, B). With 16-bit resolution, automatic cold-junction... |
Xiamen IntelliLink Global Electronic Products Co., Ltd
Fujian |
|
|
Brand Name:FOXBORO Model Number:FBM202 RH926EQ Place of Origin:USA ...FBM202 RH926EQ THERMOCOUPLE/MV INPUT MODULE The Compact FBM202 Thermocouple/mV Input Interface Module contains eight thermocouple input channels, and one isolated RTD reference junction compensation channel (for terminal temperature sensing). Each thermocouple/mV channel accepts standard thermocouples for various temperature ranges, and each provides thermocouple burnout detection (up-scale). The inputs... |
Wuhan Sean Automation Equipment Co.,Ltd
|
|
|
Place of Origin:China Brand Name:National Instruments Model Number:sbRIO-9213 名字 国家仪器 SbRIO-9213 C 系列热电偶输入模块 国家仪器 sbRIO-9213 C 系列热电偶输入模块 sbRIO-9213(部件编号:781210-01)由National Instruments设计和制造,是一款C系列温度输入模块.NI sbRIO-9213 C系列温度输入模块具有16个差分模拟温度输入通道.此外,sbRIO-9213模块有一个自动零通道和一个冷端补偿通道.内部自动零通道用于补偿偏移误差.冷端补偿通道用于补偿NI sbRIO-9213模块端子两侧由邻近热源引起的温度梯度. ... |
Shenzhen Jinxi Boyuan Technology Co., Ltd.
Guangdong |
|
|
Brand Name:Yokogawa Model Number:AAT145-S00 ...RTD Input Modules TC/RTD Input Modules (Isolated Channels) These modules receive signals from mV, thermocouple (TC), RTD, and potentiometer (POT), and they are isolated between the field and the system as well as in between each channel. They can be used in dual-redundant configuration. Items Specifications Model AAT145 Number of input channels 16, isolated |
Achievers Automation Limited
|
|
|
Brand Name:Allen Bradley Model Number:1734TBS Place of Origin:US ... scenarios. This module supports 4-channel thermocouple or RTD signal input, compatible with J, K, T, E, N, R, S, B type thermocouples and RTD sensors such as PT100 and PT1000. Through linearization processing and cold junction compensation technology, |
Xiamen Online Union Technology Co., Ltd
|
|
|
Brand Name:Yokogawa DCS Model Number:ADV551-P00 S2 Place of Origin:USA ...), and they are isolated between the field and the system as well as in between each channel. They can be used in dual-redundant configuration. the maximum period of time when the field output falls below 4 mA is 100 ms for (... |
MOORE AUTOMATION LIMITED
Fujian |
|
|
Brand Name:Yokogawa Model Number:AAR145-S00 Place of Origin:Japan Yokogawa AAR145-S00 Analog RTD Pot Input ModuleAnalog RTD Pot Input Module About Yokogawa Module The AAR145 module receives signals from mV, thermocouple (TC), RTD, and a potentiometer (POT), and they are isolated between the field and the system as well... |
TLU Technology Co., LTD
Fujian |
|
|
Brand Name:YOKOGAWA Model Number:AAT145-S00 Place of Origin:Indonesio ... each channel. They can be used in dual-redundant configuration. Items Specifications Model AAT145 AAR145 Number of input channels 16, isolated channels 16, isolated channels Input signal TC: JIS C1602:1995 (*1), IEC584:1995 Type J, K, E, B (*2), |
SC Automation Limited
|
|
|
Brand Name:YOKOGAWA Model Number:AAT145-S00 Place of Origin:Indonesio ... each channel. They can be used in dual-redundant configuration. Items Specifications Model AAT145 AAR145 Number of input channels 16, isolated channels 16, isolated channels Input signal TC: JIS C1602:1995 (*1), IEC584:1995 Type J, K, E, B (*2), |
SC Automation Limited
|
|
|
Brand Name:Allen Bradley Model Number:1756SC-IF8U Place of Origin:USA ... input types. It comes with up to eight channels of voltage that supports the above. The 1756sc-IF8U also features a 1000-Volt DC channel-to-backplane isolation that features 1000-Volt DC Channel-to-Chassis ground Isolation. The module also comes with 12.5 |
NEW SOURCE AUTOMATION CO.,LTD
|
|
|
Brand Name:Allen-Bradley Model Number:5069-IY4 Core Specifications 1. Channels and Signal Types Number of Channels: 4 channels, independently configurable Supported Signals: Voltage, Current, RTD, Thermocouple (TC), Resistance Resolution: 24-bit (Sigma-Delta ADC) Scan Time: 625μs per channel, 2.5ms... |
Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
Shaanxi |
|
|
Brand Name:LS Model Number:LS-RTD Place of Origin:China ...: 1mA Thermocouple cold junction compensation: Compensation range: -25°C ~ +75°C (1°C per 20°C error) Compensation method: internal compensation Output Output signal: 4-20mA (... |
Shenzhen Qianhai Lensen Technology Co., Ltd
Guangdong |
|
|
Brand Name:Bently Nevada Model Number:3500/65 145988-02 Place of Origin:United States ...channels of temperature monitoring and accepts both resistance temperature detector (RTD) and isolated tip thermocouple (TC) temperature inputs. The monitor conditions these inputs and compares them against user-programmable alarm setpoints. The monitor is |
Joyoung International Trading Co.,Ltd
Fujian |
|
|
Brand Name:WNK Model Number:WNK65 Place of Origin:China ... including Cu50, Cu100, PT100, PT1000 and eight types of thermocouple including E, J, B, K, N, R, S, T type. And it supports measurement of minivolt signal of -10~100mV and-100~1000mV, and resistive signal of 0~400Ω and 0~4000Ω. Isolation voltage is |
Hefei WNK Smart Technology Co.,Ltd
Anhui |
|
|
Brand Name:Sier Model Number:ST04 Place of Origin:China ...Module Input signal‘’ Resistance temperature detector (RTD),thermocouple (TC), and linear resistance. Cold-junction compensation temperature scope -20~60℃ Compensation precision ±1℃ Output signal 4-20mA Load resistance RL≤(Ue-12)/0.021 Output current of upper and lower limit overflow alarm IH=21mA,IL=3.8mA Output current of input... |
Shaanxi Sier Electronics Co., Ltd.
Shaanxi |
|
|
Brand Name:PEPPERL FUCHS Model Number:LB5105A Place of Origin:Germany ...Module Thermocouple Converter with Backplane Bus Connection and 0.75 W Power Dissipation Slots Occupied slots 2 Supply Connection backplane bus Rated voltage 12 V DC , only in connection with the power supplies LB9*** Power dissipation 0.75 W Power consumption 0.75 W Internal bus Connection backplane bus Interface manufacturer-specific bus to standard com unit Input Compensation (reference junction... |
Achievers Automation Limited
|