Sign In | Join Free | My infospaceinc.com |
|
All ct pt testing equipment wholesalers & ct pt testing equipment manufacturers come from members. We doesn't provide ct pt testing equipment products or service, please contact them directly and verify their companies info carefully.
Total 59442 products from ct pt testing equipment Manufactures & Suppliers |
|
![]() |
Brand Name:HNMC Model Number:HES-30 Place of Origin:China CT PT TEST Equipment System HES-30 Configuration Standard CT, ±0.01S% Standard PT (6kV-38.5kV), ±0.05% CT Burden (5A, 1A), ±3% PT Burden (100V, 100/√3V, 100/3V), ±3% PT Burden (110V, 110/√3V, 110/3V), ±3% Transformer Tester (Calibrator), ±2% Current generator Voltage Generator Secondary Test Cables PC Test Software CT PT Test Control Bench Technical Parameter HES-30 CT/PT Test... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
![]() |
Brand Name:Fanke High-voltage Model Number:HGQB-C series Place of Origin:Wuhan ,China ...uses advanced electronic technology to directly collect and decompose the error signals of the CT/PT, and after proper calculation, then the percentage points, phase errors and orthogonal errors of the tested CT/PT are displayed in digital LCD at the same |
WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
Hubei |
![]() |
Brand Name:RISING Model Number:RSQY-C Place of Origin:China ...CT PT Testing Equipment Secondary Voltage Drop Tester & Instrument Product Description Our secondary voltage drop tester can realize three-phase three-wire, three-phase four-wire and single-phase full-automatic measurement; it applies engineering plastic machine box, solid and durable, which effectively ensures safety of testing personnel and system; the instrument has the function of automatic range switching, which ensures testing |
Wuhan Rising Electric Co., Ltd.
Hubei |
![]() |
Model Number:CPT-III Place of Origin:China ... resistance measurement Secondary loop burden measurement Error line curve test for protection CT Transient CT parameters test CT nameplate guess Saturation hysteresis loop curve measurement Tests for voltage transformer: Turns ratio test Ratio error and |
Delta Technology (Chongqing) Co., Ltd.
Chongqing |
![]() |
Brand Name:GFUVE Model Number:GF1061 Place of Origin:China ...class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:AI Model Number:CPT-I Place of Origin:China ...current transformer and voltage transformer at rated burden and working burden in one time test. Fully Automatic CT PT Testing Equipment can automatically evaluate the test results according to the selected standard to determine whether the transformer is |
Advanced Instruments Co.,Limited
Hunan |
![]() |
Brand Name:HAOMAI Model Number:CTP-200P Place of Origin:China ... of CT/PT Analyzer CTP-200P is very high, up to 0.05%. The CT/PT Analyzer can automatically complete the test within seconds by one click of the patented multifunctional rotary mouse. It allows to test the knee-point voltage up to 40kV CTs and PTs on |
HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD
|
![]() |
Brand Name:KINGSINE Model Number:KT210 Place of Origin:China ...testing; Description ● Adopt 9.7 inch touch screen TFT LCD display with clear and beautiful software interface design, user can operate ... |
Kingsine Electric Automation Co., Ltd.
Guangdong |
![]() |
Brand Name:GDZX Model Number:ZXHQ-Y Place of Origin:China ZXHQ-Y Transformer Field Calibrator Product introduction ZXHQ-Y is a Multifunctional Current and Voltage Transformer Characteristic Tester designed in accordance with IEC60044-1 / GB1208, IEC60044-2GB1207, IEC60044-6 / GB16847 and C57.13, the instrument... |
Wuhan GDZX Power Equipment Co., Ltd
Hubei |
![]() |
Place of Origin:Wuhan Hubei China Brand Name:Huaying Model Number:Huaying Series ...CT PT Analyzer HYVA-402V 2. Equipment Description: 1 Turns Ratio, ratio error and phase error test 2 Polarity test for CT 3 Excitation curve and knee voltage measurement in power frequency for CT 4 Error curve test 5 Coil resistance test for CT and PT 6 Secondary burden test for CT 7 Turns ratio test for PT 8 Polarity test for PT 9 Excitation curve test for PT 10 Coil resistance test for PT... |
Wuhan Huaying Electric Power Tech & Science Co.,ltd
Hubei |
![]() |
Brand Name:XZH TEST Model Number:XHTX201D Place of Origin:Xi'an, Shaanxi, China ...Test Supply Transformer CT/PT Analyzer Single Phase Excitation Ratio Testing Product Description XHTX201D CT/PT ANALYZER is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, Degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopt LCD, self-equipped... |
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
|
![]() |
Place of Origin:Wuhan,Hubei,China Brand Name:Huaying CT PT Analyzer HYVA-404 Tests for Current Transformer: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for protection CT 8 Transient CT parameters test 9 CT nameplate guess 10 Saturation hysteresis loop curve measurement Tests for Voltage Transformer: 1 Turns ratio test... |
Wuhan Huaying Electric Power Tech & Science Co.,ltd
Hubei |
![]() |
Brand Name:YUYANG Model Number:CPT-I Place of Origin:China ...Test Set CT PT Analyzer Test for current transformer: Excitation curve and parameters test Turns ratio test Ratio and phase error test Polarity mark check Winding resistance measurement Secondary loop burden measurement Error line curve test for protection CT Transient CT parameters test CT nameplate guess Saturation hysteresis loop curve measurement Tests for Potencial Transformer: Turns ratio test |
DONGGUAN YUYANG INSTRUMENT CO., LTD
Guangdong |
![]() |
Brand Name:KRE Model Number:KE8300B Place of Origin:China ...Equipment Class 0.02 CT / PT IEC Standard KE8300B Three phase Meter Calibration Equipment Accuracy : 0.02 , Used for the test of standard meter and mounted meter with a accuracy class below 0.1, Number of meter position : 3-12 Product highlghts: High accuracy: 0.02% Auto protection of short circuit of voltage, open circuit of current, and overload. Test... |
Guangzhou Kingrise Enterprises Co., Ltd.
Guangdong |
![]() |
Brand Name:XG Model Number:JLS-35 Place of Origin:XIAN,CHINA ...-phase voltage transformers and current transformer. PT and CT are both electromagnetic type. This type of transformer is application to 50 HZ (rated frequency), three-phase AC, 6kv, 10kv(rated voltage) ... |
Xi'an Xigao Electricenergy Group Co., Ltd.
Shanxi |
![]() |
Brand Name:JC Model Number:Kz Place of Origin:China ...equipment for transformer CT PT and (casing bushing) product details Application scope: The vacuum oil injection equipment for transformers (bushings) is suitable for vacuum oil injection treatment of high-pressure oil immersed transformers, high-voltage bushings, and other products. Product features: Since its establishment in 1992, Kaixuan Vacuum has been committed to the research and development of vacuum equipment... |
Wuxi Jiachen Power Electronics Equipment Co., Ltd.
Jiangsu |
![]() |
Brand Name:GENY Model Number:HN-2K01B2 Place of Origin:China Automatic Portable CT On-Site Transformer Test Equipment for Testing of CT’s Radio/Angle Error in Accuracy Class 0.05 Specifications: Current Mutual-inductor On-site Calibration Device The product is mainly used to test one grade to 0.2S grade field ... |
Guangzhou GENY Electric Co., Ltd
|