Transformer Oil Breakdown Voltage Test Kit 100KV Transformer oil tester
|
... Parameters: 1 Voltage OEM for clients 2 AC220V±10% power supply input 3 Output voltage:AC 0V~100KV 4 Rate of voltage rise: 0.5kv/s±10%, 2kv/s±5%, 3kv/s±5%,5kv/s±5% 5 Max test times: 9 6 Init wait times:0~999s 7 ......
Wuhan Huaying Electric Power Tech & Science Co.,ltd
|
BDV-II 100kv Dielectric Insulating Oil Test Kit Breakdown Voltage Bdv Transformer Oil Tester
|
...100kv Dielectric Insulating Oil Test Kit Breakdown Voltage Bdv Transformer Oil Tester Introduction: Bdv-II 100kv Kit Breakdown Voltage Bdv Transformer Oil Tester is developed according to the national standard IEC156 Insulating Oil Dielectric Strength Testing Method ; Bdv-II 100kv Kit Breakdown Voltage Bdv Transformer Oil Tester has large LCD display, micro-printer and can store 100 groups data; Bdv-II 100kv......
Delta Technology (Chongqing) Co., Ltd.
|
IEC 60156 100KV Transformer Oil Test Set For Insulating Liquid Testing
|
100KV Transformer Oil Test Set I. Introduction: BDV-II Transformer Oil Test Set is designed according to the national standard IEC156 Insulation Oil Dielectric Strength Test Method; This transformer oil tester has large LCD display, micro-printer and can store 100 groups data; This oil tester......
Advanced Instruments Co.,Limited
|
LCD Display 100KV Transformer Oil BDV Tester
|
RSJY-80S 100kv Transformer Oil BDV Tester Oil Dielectric Strength Tester Product Introduction This equipment was designed on basis of GB-86 Oil-insulating testing, the process and result displayed by LCD, built-in EEPROM , can save 50 groups test results......
Wuhan Rising Electric Co., Ltd.
|
Thermoelectric Cooling 16 Bit MCU Transformer Oil Tester For Pour Point Test
|
Transformer Oil Testing Equipment 220V 50HZ Automatic Solidifying Point Pour Point T Transformer Oil Tester The instrument is for oil solidifying point test. It adopts 16 bit MCU, thermoelectric cooling system. It is suitable for transformer plant, power supply department, oil......
Wuhan GDZX Power Equipment Co., Ltd
|
80KV Dielectric Portable Transformer Oil Tester , Print Transformer Oil Testing Kit
|
...self-contained, compact and portable giving smooth variable test voltage from 0 to 100 kV for testing the dielectric strength of transformer oil in accordance with all international standards like ASTM D1816/IEC156/IS6792/ ASTM D877/ UNE 21 specifications....
Sino-NSH Oil Purifier Manufacture Co., Ltd
|
ASTM E659 Transformer Oil Tester Fuel Oil Fire Resistant Oil Self Ignition Point Tester
|
... Point Tester. It provides fast and accurate testing results, and has strong data storage and output functions. This equipment has power consumption of less than 1500W, LCD ......
Shandong Shengtai instrument co.,ltd
|
BDV Insulatiing Oil Test Set, Transformer Oil Tester (Test Dielectric Strength)
|
...Oil Tester is for testing 60kV, 80kV, and 100 kV. IIJ-II series fully automatic insulating oil tester is apply to test the insulating oil's dielectric strength, which is designed as per the requirement of IEC165 Testing Method of Insulation Oil Medium Strength, which via proper programming, has got functions of auto boosting, step down, stirring, display and print out. After breakdown of oil......
FUOOTECH Oil Filtration Group
|
100KV Transformer Oil Dielectric Strength Tester LCD Screen
|
Insulation Oil Dielectric Strength Test Kit MCOT80 Features With microprocessor, automatically fulfill the test for oil circulation with a range of 0~80KV Large screen LCD display Automatically complete withstand-voltage test of oil after simple setting......
Zhengzhou Great Electric Co.,Ltd.
|
Transformer oil tester 100kv wuhan maker
|
I. Introdução 1. O verificador fase trifásica/monofásica TTR de HYBC-901 ou o medidor chamado da relação de Transformador Giro são projetados que concordam IEC76-1, IEC60044 e GB/T1094. 2. O medidor da relação das voltas do transformador fase trifásica/......
Wuhan Huaying Electric Power Tech & Science Co.,ltd
|