Single & Dual Channel Loop Sensor: AC/DC Power For Industrial Door
And Access Control

Product Overview
JUTAI single and dual channel loop sensors are industrial-grade
detection solutions optimized for industrial door automation and
access control systems, supporting both AC (100-240V) and DC
(12-24V) power inputs. Built with rugged reliability and flexible
configuration, they deliver precise vehicle presence and pulse
detection to streamline workflow efficiency and enhance security.
Our product range caters to diverse industrial and access control
needs:
- Single Channel (LD100 AC / LD102 DC): Ideal for basic industrial door activation and single-point access
control, focusing on reliable presence/pulse detection.
- Dual Channel (LD200 AC / LD202 DC): Equipped with directional sensing and dual-zone monitoring,
perfect for entry/exit access management and coordinated industrial
door operations.
All sensors seamlessly detect cars, trucks, forklifts, and
motorcycles, maintaining stable performance in harsh industrial
environments and outdoor access points.
Key Features
- Dual Power Flexibility: Supports AC 100-240V (permanent industrial installations) and DC
12-24V (mobile/backup power setups), adapting to diverse power
supply conditions.
- Adjustable Sensitivity: Single Channel models offer 16-level sensitivity tuning; Dual
Channel variants provide 8-level independent adjustment per
channel, minimizing false triggers from metal debris or adjacent
equipment.
- Configurable Operating Modes: Presence mode (holds industrial doors open during vehicle
passage), pulse mode (triggers one-time door activation), and
auto-reset (prevents misoperation); Dual Channel adds 3 directional
detection modes for access entry/exit logic.
- Industrial-Grade Durability: Weatherproof, dustproof housing, -40°C~+70°C operating temperature
range, and 95% non-condensing humidity tolerance - resistant to
industrial vibration, dust, and extreme weather.
- Real-Time Status Monitoring: LED indicators for power, detection status, and loop faults
(short/open circuit), enabling quick on-site troubleshooting to
reduce industrial downtime.
- Seamless Access Control Integration: Dual relay outputs (per channel for Dual Channel models) connect
with industrial door controllers, access control panels, and
security systems - no complex programming required.
- Anti-Interference Design: 4-step selectable frequency (20-80 kHz for Single Channel; 20-100
kHz for Dual Channel) avoids cross-talk with industrial machinery
or adjacent detection loops.
Technical Specifications
| Parameter | Single Channel (LD100 / LD102) | Dual Channel (LD200 / LD202) |
|---|
| Power Supply | 100-240V AC or 12-24V DC | 100-240V AC or 12-24V DC |
| Detection Channels | 1 | 2 Independent Channels |
| Sensitivity Adjustment | 16-level | 8-level per channel |
| Frequency Selection | 4-step (20-80 kHz) | 4-step (20-100 kHz) |
| Relay Outputs | 2 (Presence + Pulse/Fault) | 2 (One per channel: COM + NO) |
| Direction Detection | Not Available | Yes (Configurable via DIP switches) |
| Response Time | 10-90 ms | 10-90 ms |
| Operating Temperature | -40°C to +70°C | -40°C to +70°C |
| Indicators | Power LED + Detection LED | Power LED + CH1/CH2 Detection LEDs |
| Humidity Tolerance | Up to 95% RH (non-condensing) | Up to 95% RH (non-condensing) |
| Loop Inductance Range | 20-2000 µH | 20-2000 µH per channel |
Loop Installation Guide
| Loop Perimeter | Recommended Wire Turns |
|---|
| 3-4 meters | 6 turns |
| 4-6 meters | 5 turns |
| 6-10 meters | 4 turns |
| 10-20 meters | 3 turns |
| Over 20 meters | 2 turns |
Installation Note: Loops sealed with quick-set epoxy or hot bitumen to withstand
industrial floor traffic and environmental wear.
Ideal Applications
- Single Channel Use Cases: Industrial roller door/high-speed door activation, warehouse
access gate automation, forklift entry detection, loading dock door
control, simple access point presence sensing.
- Dual Channel Use Cases: Industrial entry/exit access management, coordinated dual-door
operation, access control with directional logic
(entry-only/exit-only), toll gate access for industrial vehicles,
multi-lane access control in factories/logistics parks.
Why Choose JUTAI Loop Sensors?
- 15+ years of expertise in industrial-grade vehicle detection
technology, tailored to industrial door and access control
workflows.
- Dual power options (AC/DC) for flexible deployment in factories,
warehouses, and outdoor access points.
- Rigorous quality testing to ensure resistance to industrial
vibration, dust, and extreme temperatures.
- OEM/ODM customization support + standard order flexibility,
adapting to specific project requirements.
- 2-year warranty + 24/7 technical support for seamless integration
and long-term reliability.
Model Selection Guide
- Choose Single Channel sensors for basic industrial door activation and single-point
access control.
- Choose Dual Channel sensors for directional access management, dual-zone detection, or
coordinated industrial door systems.

Connections and Indicators

Indicators and Switches
- Power LED (RED): Illuminates to indicate "Power ON."
- CH1 Detection LED:
- Steady On: Indicates vehicle detection.
- Slow Blinking: Indicates a loop short circuit or insufficient
twists after the loop.
- Fast Blinking: Indicates a loop open circuit or excessive twists
after the loop.
- CH2 Detection LED:
- Steady On: Indicates vehicle detection.
- Slow Blinking: Indicates a loop short circuit or insufficient
twists after the loop.
- Fast Blinking: Indicates a loop open circuit or excessive twists
after the loop.
Sensitivity Selection
Sensitivity and frequency adjustment is facilitated through a 7-way
dip switch and 10-way dip switch settings. Users can choose from 8
different sensitivity settings by configuring the dip switch
positions according to the provided tables.
- Dip switches 6, 7, and 8 govern CH1 sensitivity, ranging from 0.8
(least sensitive) to 0.015 (most sensitive).
- Dip switches 3, 4, and 5 control CH2 sensitivity, ranging from 0.8
(least sensitive) to 0.015 (most sensitive).

Switch Configuration Details
Switch 1=S1: Channel 1 Loop Function Selection (10 way dip switch)
(1) DIP 1 & DIP 2: Special Sensitivity Increase For Both Trailer (Both Channels).

(2) D3, D4, D5 and Switch 2=S2 D1, D2: Setting Special Functions (Mode1, 2, 3 Direction Detection. Mode
4, 5, 6 Normal mode, two loop detection are separated).

(3) D6 & D7 & D8 and Switch 2=S2 D3 & D4 & D5: Setting CH1 and CH2 Sensitivity Selection (Eight Levels Choices).

(4) D9 & D10 and Switch2=S2 D6, D7: Setting Frequency (20 K to 100 KHz).

Reset Button: Please note: The LD-200 must be reset every time a setting change
is made to the Dip switches.
Installation Precautions and Troubleshooting
- Coil Cutting Size and Embedding Guidelines are as shown in the
diagram on the right.
- It is recommended to use ferromagnetic wires for the induction
coil, with a total length of up to 500 meters.
- The cutting size of the coil should be a rectangle with a length of
1.0 to 2.0 meters and a width of 0.8 to 1.2 meters, avoiding right
angles at corners as much as possible.
Recommended Installation Overview

When installation, please keep the product plug and socket in the
vertical direction.

Application Scenarios
The JUTAI LD200/202 double-channel vehicle loop detector series,
equipped with direction recognition function, is ideal for numerous
single-channel entry and exit scenarios. When integrated with the
JUTAI One door controller (Model: AC-11), JUTAI gate barrier
(Model: BR-110), and JUTAI long-range RFID reader (Model: PUHF-9),
along with high-temperature resistance loop coils (Model: JTHT-11),
it forms a seamless solution for single-channel entry/exit access
control systems.

Working Principle
Entry Process:- When a car enters the community or parking lot, the two loop coils
are pressed simultaneously.
- The JUTAI Double Channel Loop Detector (LD-200/202) triggers the
UHF reader located at the entrance.
- The UHF reader reads the card ID and sends it to the controller
(AC-11) via Wiegand output.
- The controller verifies the ID's validity and outputs a relay
signal to open the gate barrier.
- The car enters the community or parking lot, and as it passes the
barrier gate, the barrier arm lowers automatically.
- The JUTAI Single Channel Loop Detector (LD-100/102) ensures safety
and anti-smashing functionality during this process.
Exit Process:- When a car exits the community or parking lot, it passes by an
inside UHF reader.
- The LD-200/LD-202 triggers the UHF reader, which reads the card and
sends the ID to the controller.
- The controller verifies the ID's validity and outputs a relay
signal to open the gate barrier for the car to exit.
- As the car passes through the barrier gate, the barrier arm lowers
automatically.
- The LD-100/102 provides safety and anti-smashing functionality
during this process.
Direction Recognition:- The Direction Recognition Function of LD-200/LD-202 ensures that
the double channels loop detector does not trigger the signal again
when the car passes another UHF reader, thereby recording only the
entry or exit records in the system.

The JUTAI LD-200/202 Double Channel Loop Detector can also function
as two independent single-channel loop detectors. This
configuration is suitable for standard one-in and one-out parking
lots, where there is one barrier and one long-range reader at both
the entrance and exit.
In this setup, one loop coil is used to trigger the reader and read
the card, while the other loop coil is dedicated to the barrier's
anti-smashing function. By utilizing the LD-200/202 as two
independent loop detectors, there is a potential cost-saving
benefit from an economic standpoint. This setup reduces some of the
hardware costs associated with using separate detectors for each
function.
This functionality is achieved by enabling the Independent Working
Mode feature of the LD-200/202, allowing it to operate effectively
in this dual capacity.