Vehicle Detection Sensor: Single Channel For Gate Automation, Dual
Channel For Direction Sensing & Counting

JUTAI vehicle detection sensors offer targeted solutions for access
control and traffic management, with single-channel models
optimized for gate automation and dual-channel variants engineered
for directional sensing and traffic counting. Built with
industrial-grade precision and rugged durability, these sensors
deliver reliable performance for indoor/outdoor applications,
including parking lots, industrial facilities, residential
complexes, and toll plazas.
Product Line Overview
Single Channel Sensors
Designed for one-point vehicle detection, ideal for triggering
automatic gate opening/closing, industrial door activation, and
basic access control. Equipped with high sensitivity to detect
cars, motorcycles, and small commercial vehicles, minimizing false
triggers.
Dual Channel Sensors
Feature dual independent detection zones and configurable direction
modes, enabling accurate judgment of vehicle travel direction
(entry/exit) and real-time traffic counting. Perfect for entry/exit
management systems, traffic flow analysis, and multi-lane access
control.
All sensors support seamless integration with gate controllers,
traffic counters, and access control platforms, with weatherproof
housing and wide temperature tolerance to adapt to harsh
environmental conditions.
Key Features
Single Channel (Gate Automation Focus)
- Gate-optimized Trigger Modes: Supports pulse output (one-time gate lifting) and presence hold
(keeps gate open during vehicle passage), with 10-90 ms response
time to avoid collisions.
- 16-level Adjustable Sensitivity: Fine-tune detection precision to match vehicle sizes (from
motorcycles to SUVs) and eliminate false triggers from metal debris
or adjacent structures.
- Easy Configuration: DIP switch control for sensitivity and operating modes, no complex
software required—enables quick on-site setup for gate systems.
- Industrial-grade Reliability: -40°C to +70°C operating temperature range and 95% non-condensing
humidity tolerance, suitable for outdoor gate installations.
Dual Channel (Direction Sensing & Counting Focus)
- 3 Configurable Direction Modes: Accurately identifies vehicle travel direction (CH1→CH2 or
CH2→CH1) to support entry/exit counting and bidirectional traffic
flow analysis.
- Independent 8-level Sensitivity per Channel: Adjust each detection zone's sensitivity separately to adapt to
different lane conditions and vehicle types.
- Anti-interference Design: 4-step selectable frequency (20-100 kHz) eliminates cross-talk
between adjacent channels or loops, ensuring counting accuracy in
high-traffic areas.
- Real-time Counting Compatibility: Seamlessly integrates with traffic counting displays and
management software to provide real-time occupancy data for parking
lots or roadways.
Universal Advantages
- Weatherproof Housing: Sealed, rugged housing protects against water, dust, and
corrosion, ideal for outdoor deployments.
- Real-time Status Monitoring: LED indicators for power, detection status, and loop faults
(short/open circuit) enable rapid troubleshooting.
- Flexible Power Options: Supports 100-240V AC for permanent installations and 12-24V DC for
temporary setups (e.g., construction site gates).
- Dual Relay Outputs: Ensures reliable connection with gate controllers, traffic
counters, and other automation equipment.
Technical Specifications Summary
| Parameter | Single Channel | Dual Channel |
|---|
| Detection Channels | 1 | 2 Independent |
| Core Function | Gate automation, presence detection | Direction sensing, traffic counting |
| Sensitivity Adjustment | 16-level | 8-level per channel |
| Direction Detection | No | Yes (3 modes, DIP configurable) |
| Frequency Range | 20-80 kHz | 20-100 kHz |
| Power Supply | 100-240V AC / 12-24V DC | 100-240V AC / 12-24V DC |
| Response Time | 10-90 ms | 10-90 ms |
| Operating Temperature | -40°C to +70°C | -40°C to +70°C |
| Humidity Tolerance | 95% RH (non-condensing) | 95% RH (non-condensing) |
| Relay Outputs | 2 (Presence + Pulse/Fault) | 2 (1 per channel: COM + NO) |
| Loop Inductance Range | 20-2000 µH | 20-2000 µH per channel |
Loop Installation Guide
| Loop Perimeter | Recommended Wire Turns |
|---|
| 3-4 meters | 6 turns |
| 4-6 meters | 5 turns |
| 6-10 meters | 4 turns |
| 10-20 meters | 3 turns |
| Over 20 meters | 2 turns |
Installation Note: For dual-channel direction sensing, install loops 1m apart along
the vehicle travel path; seal wires with quick-set epoxy to
withstand road traffic wear.
Ideal Applications
Single Channel Use Cases
- Residential complex gate automation
- Industrial warehouse door activation
- Small parking lot barrier gate control
- Commercial building access gate triggering
- Construction site temporary gate control
Dual Channel Use Cases
- Parking lot entry/exit counting systems
- Shopping mall traffic flow direction analysis
- Toll booth vehicle classification and counting
- Industrial park dual-lane access control
- Airport parking bidirectional traffic management
Why Choose JUTAI Vehicle Detection Sensors?
- Targeted Solutions: Single-channel models for gate automation, dual-channel for
direction sensing and counting—no unnecessary features, reducing
costs.
- Industrial-grade Durability: Weatherproof housing and wide temperature tolerance ensure
reliable performance in harsh environments.
- Easy Integration: Compatible with standard gate controllers, traffic counters, and
access control systems—no complex programming.
- 15+ Years of Expertise: Specialized in vehicle detection technology, with rigorous
pre-shipment testing for quality assurance.
- Customization Support: OEM/ODM services available to meet specific project requirements.
- 2-Year Warranty: Backed by a 2-year manufacturer's warranty and dedicated technical
support.
Selecting the Right Model
- Choose Single Channel sensors for basic gate automation and one-point presence
detection.
- Choose Dual Channel sensors for direction sensing, traffic counting, or multi-lane
access control.
Order Now
Contact us today to request free samples, get customized quotes, or
consult technical details. JUTAI vehicle detection sensors deliver
precise, reliable performance for your gate automation and traffic
counting projects.

Connections

Indicators and Switches
- Power LED (RED): Illuminates to indicate "Power ON."
- CH1 Detection LED:
- Steady On: Indicates vehicle detection.
- Slow Blinking: Indicates a loop short circuit or insufficient
twists after the loop.
- Fast Blinking: Indicates a loop open circuit or excessive twists
after the loop.
- CH2 Detection LED:
- Steady On: Indicates vehicle detection.
- Slow Blinking: Indicates a loop short circuit or insufficient
twists after the loop.
- Fast Blinking: Indicates a loop open circuit or excessive twists
after the loop.
Sensitivity Selection
Sensitivity and frequency adjustment is facilitated through a 7-way
dip switch and 10-way dip switch settings. Users can choose from 8
different sensitivity settings by configuring the dip switch
positions according to the provided tables.
- Dip switches 6, 7, and 8 govern CH1 sensitivity, ranging from 0.8
(least sensitive) to 0.015 (most sensitive).
- Dip switches 3, 4, and 5 control CH2 sensitivity, ranging from 0.8
(least sensitive) to 0.015 (most sensitive).

Switch 1 (S1): Channel 1 Loop Function Selection (10-way dip
switch)
Special Sensitivity Increase For Both Trailer (Both Channels)

Special Functions Setting (Mode1, 2, 3 Direction Detection)

CH1 and CH2 Sensitivity Selection (Eight Levels Choices)

Frequency Selection (20 K to 100 KHz)

Reset Button: Please note: The LD-200 must be reset every time a setting change
is made to the Dip switches.
Installation Precautions and Troubleshooting
- Coil Cutting Size and Embedding Guidelines are as shown in the
diagram on the right.
- It is recommended to use ferromagnetic wires for the induction
coil, with a total length of up to 500 meters.
- The cutting size of the coil should be a rectangle with a length of
1.0 to 2.0 meters and a width of 0.8 to 1.2 meters, avoiding right
angles at corners as much as possible.
Recommended Installation Overview of Basic Typical Coil Turns

When installation, please keep the product plug and socket in the
vertical direction

Application
The JUTAI LD200/202 double-channel vehicle loop detector series,
equipped with direction recognition function, is ideal for numerous
single-channel entry and exit scenarios. When integrated with the
JUTAI One door controller (Model: AC-11), JUTAI gate barrier
(Model: BR-110), and JUTAI long-range RFID reader (Model: PUHF-9),
along with high-temperature resistance loop coils (Model: JTHT-11),
it forms a seamless solution for single-channel entry/exit access
control systems.

Working Principle
Entry Process:
- When a car enters the community or parking lot, the two loop coils
are pressed simultaneously.
- The JUTAI Double Channel Loop Detector (LD-200/202) triggers the
UHF reader located at the entrance.
- The UHF reader reads the card ID and sends it to the controller
(AC-11) via Wiegand output.
- The controller verifies the ID's validity and outputs a relay
signal to open the gate barrier.
- The car enters the community or parking lot, and as it passes the
barrier gate, the barrier arm lowers automatically.
- The JUTAI Single Channel Loop Detector (LD-100/102) ensures safety
and anti-smashing functionality during this process.
Exit Process:
- When a car exits the community or parking lot, it passes by an
inside UHF reader.
- The LD-200/LD-202 triggers the UHF reader, which reads the card and
sends the ID to the controller.
- The controller verifies the ID's validity and outputs a relay
signal to open the gate barrier for the car to exit.
- As the car passes through the barrier gate, the barrier arm lowers
automatically.
- The LD-100/102 provides safety and anti-smashing functionality
during this process.
Direction Recognition:
The Direction Recognition Function of LD-200/LD-202 ensures that
the double channels loop detector does not trigger the signal again
when the car passes another UHF reader, thereby recording only the
entry or exit records in the system.

The JUTAI LD-200/202 Double Channel Loop Detector can also function
as two independent single-channel loop detectors. This
configuration is suitable for standard one-in and one-out parking
lots, where there is one barrier and one long-range reader at both
the entrance and exit.
In this setup, one loop coil is used to trigger the reader and read
the card, while the other loop coil is dedicated to the barrier's
anti-smashing function. By utilizing the LD-200/202 as two
independent loop detectors, there is a potential cost-saving
benefit from an economic standpoint. This setup reduces some of the
hardware costs associated with using separate detectors for each
function.
This functionality is achieved by enabling the Independent Working
Mode feature of the LD-200/202, allowing it to operate effectively
in this dual capacity.