Premium 8-Zone Conventional Fire Alarm Controller Fire Safety Solutions

Product Description:

The information provided in this manual covers the Master and Slave fire alarm control panel. The panel range is designed to
meet the requirements of EN54 Parts 2 & 4.
A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical, ionization,
photoelectric, photoelectric-thermal and heat detectors.
Each of the system components has been specifically designed to operate as part of the system. This provides assurance
that the control panel, smoke detectors, interface devices and the ancillary components are all fully compatible with one
another and that the full range of system functionality is supported by each device.
The fire alarm control panels (8 Zones) provide all of the sophisticated features required of a leading edge conventional fire
alarm system along with the simple operation and efficient installation methods demanded by both installers and building users

Product Features:
8 conventional input zones.
Housed in a 370mm W x 440mm H x 100mm D metal enclosure.
Each zone can be connected with 30 conventional fire detectors. Each panel has external devices control output points, Through the points, the panel can control such external devices as bell, siren, flame detector, beam detector etc.
Dedicated alarm and trouble relays.
Enclosure supports 1 12V, 4.5Ah backup batteries.
The panel can be used independently or connect by RS485.
1 RS485 can be able to connect the other panel.

Technical parameters:

Primary AC120VAC 50/60 Hz Power supply ratingRepeatability:≤± 2% FS;
240VAC 50/60 HzZero drift:≤± 1% FS/6h;
Power supply rating2 Amps @ 24VDC
Maximum Battery Charging Current0.90 Amps @ 26VDC
Initiating Device Circuits ZonesAlarm Zone 2/4/8/16
Normal Initiating Operating Voltage22VDC, Maximum 26VDC, regulated
Normal Monitor Current<50mA
Alarm Current<150 mA
Short Circuit Initiating Current (per zone)35mA MaximumWorking temperature:-20~60 degrees;
Working humidity: 0~100% RH (no condensation)
Maximum Initiating Resistance (per zone)10 ohmsOutput method:(choose one from three) or contact sales
1. 4-20mA signal: standard 16 bit precision 4-20mA output chip, transmission distance of 1km
Initiating End-of-Line Resistor4K7 ohms, 1/2W 5%2. RS485 signal: using standard MODBUS RTU protocol, transmission distance of 2Km
Standby Detector Current (per zone)4mA maximum3. Switching signal: Standard configuration includes 2 sets of relays,
optional third set of relays, passive contacts, capacity 125VAC/0.3A
30VDC/1A
Maximum Detector Count (per zone)30 detectors
Initiating Cabling Type18AWG Twisted Shielded pair (14 - 18 AWG)
Detector Base Impedance430 ohms
Fault Relay rating2A & 30VAC, resistive
Alarm( Auxiliary ) Relay rating2A & 30VAC, resistive