| Sign In | Join Free | My infospaceinc.com |
|
| Categories | Medical Equipment Repair |
|---|---|
| Brand Name: | Drager |
| Model Number: | 8602770 |
| Certification: | FDA |
| Place of Origin: | US |
| MOQ: | 1 unit |
| Price: | Negotiate |
| Payment Terms: | T/T,Western Union,Paypal |
| Supply Ability: | 100 unit per week |
| Delivery Time: | Within 7 days |
| Packaging Details: | 1 unit per case |
| Name: | Drager 8602770 pressure sensor |
| Application: | Anesthesia machine |
| Color: | Silver |
| Material: | Plastic and Metal |
| Feature: | Original |
| Respond time: | < 10 ms |
| Company Info. |
| Precise life group limited |
| Verified Supplier |
| View Contact Details |
| Product List |
Drager 8602770 Absolute Pressure Sensor system Primus 8602770 Absolute pressure sensor
The Drager 8602770 Absolute Pressure Sensor is a high-precision OEM sensing module specifically engineered for the Drager Primus and Primus IE anesthesia workstations. This critical component serves as the primary airway pressure monitoring interface within the breathing system, delivering real-time, absolute pressure measurements to the ventilator's main control board. Utilizing advanced piezoresistive or capacitive sensing technology, the 8602770 sensor ensures accurate tracking of peak inspiratory pressure (PIP), mean airway pressure, plateau pressure, and positive end-expiratory pressure (PEEP). Designed to meet stringent medical device standards, the sensor features a compact, board-mountable form factor with medical-grade housing that resists moisture, anesthetic agent exposure, and repeated sterilization cycles. As a genuine Drager replacement part, the 8602770 guarantees seamless integration with the Primus platform's E-Vent plus ventilation system, enabling reliable tidal volume calculation, leak detection, and patient safety alarm functionality throughout complex surgical procedures.
Specification medical equipment repair parts:
Brand: Drager |
Part number: 8602770 |
Name: Absolute pressure sensor |
Machine model: Primus |
Warranty: 90 days |
Delivery time: about 1 week |
Description medical equipment repair parts:
This essential sensing component is extensively deployed in tertiary hospital operating rooms, cardiothoracic surgical suites, neuroanesthesia theaters, and academic medical centers utilizing the Drager Primus anesthesia platform. The 8602770 absolute pressure sensor is primarily utilized during mechanical ventilation management, where precise airway pressure monitoring is critical for lung-protective ventilation strategies. Anesthesiologists and respiratory therapists rely on this sensor to maintain optimal PEEP levels, prevent barotrauma through accurate peak pressure limiting, and ensure consistent tidal volume delivery across volume-controlled and pressure-controlled modes. Biomedical engineering technicians integrate the sensor into scheduled preventive maintenance (PM) protocols, performing calibration verification and drift compensation to uphold manufacturer performance specifications. The sensor's absolute pressure reference eliminates atmospheric fluctuations, ensuring stable measurements during patient transport, altitude variations, or changes in operating room ventilation conditions.
Advantage:
OEM Precision Calibration: Factory-calibrated to Drager's exacting standards, the 8602770 delivers consistent accuracy without frequent field adjustments, reducing maintenance downtime and ensuring reliable clinical data throughout the sensor's service life.
Rapid Dynamic Response: With sub-10ms response time, the sensor
captures fast pressure transients during spontaneous breathing
efforts, coughing, or ventilator mode transitions, enabling the
Primus system to adjust flow delivery instantaneously for optimal
patient-ventilator synchrony.
Medical-Grade Durability: Constructed with biocompatible materials
and sealed against moisture and volatile anesthetic agents, the
sensor withstands rigorous clinical environments and routine
disinfection procedures without performance degradation.
Seamless System Integration: Designed as a direct plug-and-play
replacement for the Primus breathing system, the 8602770 requires
no software modifications or hardware adapters, ensuring immediate
compatibility with existing E-Vent plus control algorithms.
Enhanced Patient Safety: Accurate absolute pressure monitoring
enables reliable detection of circuit obstructions, disconnections,
or kinks, triggering timely audible and visual alarms that protect
patients from hypoventilation or excessive airway pressures.


|