Nihon Kohden ECG-1350P 12-Lead Electrocardiograph With Thermal
Array Printer Used Unit
The Nihon Kohden ECG-1350P is a professional 12-lead
electrocardiograph designed for accurate cardiac diagnosis in
hospitals, clinics, and emergency departments. This refurbished unit features a clear LCD screen displaying
real-time ECG waveforms, a thermal array printer for instant
hard-copy results, and intuitive control buttons for easy
operation.
Despite visible signs of prior use (minor scratches and wear on the
casing), the device maintains full functionality: the screen
displays crisp waveforms, all buttons respond reliably, and the
printer produces clear, smudge-free printouts. Ideal for healthcare
facilities seeking a cost-effective, high-performance ECG solution,
it supports both AC power and rechargeable battery operation for
flexible use in various settings.

| Product Name | Nihon Kohden ECG-1350P Electrocardiograph |
|---|
| Model | ECG-1350P |
|---|
| Material | Medical-Grade Plastic Casing |
|---|
| Function | ECG Recording, Waveform Analysis, Thermal Printing |
|---|
| Color | White |
|---|
| Warranty | 90 days |
|---|
1. Pre-Use Check:
Ensure the battery is charged (green LED indicator) or connect to
AC power. Verify electrode cables are securely attached to the
patient and device.
2. Operation:
Press the "Start/Stop" button to begin recording; use the "Lead
Select" keys to switch between 12 leads. Adjust gain (sensitivity)
and paper speed via the control panel as needed.
3. Printing:
Press the "Print" button to output the current waveform. Replace
the thermal paper roll when the "Paper End" indicator lights up.
4. Maintenance:
Clean the casing with a soft, damp cloth (avoid harsh chemicals).
Store in a dry environment (10-40°C) to prevent moisture damage.
5. Battery Care:
Fully charge the battery before first use; avoid deep discharge
(recharge when the low-battery indicator appears).
1. Unpacking:
Remove the device from packaging and check for physical damage.
Ensure all accessories (electrode cables, power cord, thermal
paper) are included.
2. Power Connection:
Plug the AC power cord into the device’s rear socket and a grounded
outlet. For battery use, ensure the battery is installed (located
in the bottom compartment).
3. Electrode Connection:
Attach the 10 electrode cables (RA, LA, RL, LL, V1-V6) to the
corresponding ports on the device. Apply electrodes to the
patient’s skin (clean and dry) as per standard ECG placement
guidelines.
4. Paper Loading:
Open the printer cover, insert the thermal paper roll (print side
facing down), and close the cover until it clicks.