VFD-C200: Smart Vector Inverter for Tough Environments & Precise
Control
The VFD-C200 is a high-end intelligent vector inverter designed for
small-sized equipment, with a power range of 0.4kW-7.5kW. It
features advanced FOC vector control, 5,000-step PLC programming,
and PID regulation, supporting both induction motors and permanent
magnet motors. With multiple communication protocols and innovative
designs including anti-fouling coating and optimized air duct
systems, it withstands harsh environments while delivering precise
control for applications in food packaging, textiles, fans, water
pumps, and more.
Core Product Features
Diversified Motor Control with Precise Adaptability
- Advanced flux vector control technology with FOC+PG, sensorless
FOC, and sensorless permanent magnet motor control modes
- Compatible with induction motors (IM) and permanent magnet motors
(PM)
- Built-in resonance frequency suppression/skip function and PG card
for closed-loop vector control
- 0.4kW-7.5kW power range for diverse small-horsepower equipment
needs
Integrated Intelligent Control for Cost Reduction & Efficiency
Improvement
- Built-in 5,000-step PLC program capacity reduces need for
additional PLC modules
- Standard PID control function for pressure and flow closed-loop
control scenarios
- Supports MODBUS (RS-485) and CANopen protocols with optional
PROFIBUS-DP and Ethernet communication cards
Strong Environmental Adaptability & Stable Reliability
- IEC 60721-3-3 3C2 grade anti-fouling coating protects against dust
and moisture
- Optimized air duct design prevents dust intrusion while ensuring
efficient cooling
- Some models withstand temperatures up to 50℃ with enlarged fan
design for dust-prone environments
Practical Functions & Easy Operation
- High-brightness LED operation panel with extension cable
compatibility
- Built-in brake chopper for stable motor deceleration and energy
management
- Wide application range including food packaging, conveyors, textile
machines, woodworking, fans, pumps, and solar equipment
VFD-C200 Vector Inverter Core Specifications
| Parameter Category | Specific Specifications |
|---|
| Power Range | 0.4kW - 7.5kW |
| Input Voltage | 1-phase 220V ±15% / 3-phase 220V ±15% / 3-phase 380V ±15%
(depending on model) |
| Input Frequency | 50Hz / 60Hz ±5% |
| Output Voltage | 0 - Input voltage (3-phase, sine wave output) |
| Output Frequency Range | 0.1Hz - 600Hz |
| Control Modes | FOC+PG closed-loop vector control, sensorless FOC vector control,
sensorless PM motor control, V/F control |
| Motor Compatibility | Induction Motor (IM), Permanent Magnet Motor (PM) |
| PLC Function | Built-in, 5,000 steps program capacity |
| Control Functions | PID control, resonance frequency suppression/skip, torque limit,
speed limit, slip compensation |
| Communication Interfaces | Standard: MODBUS (RS-485), CANopen; Optional: PROFIBUS-DP, Ethernet
(EtherNet/IP, Modbus TCP) |
| Environmental Protection | Circuit board: IEC 60721-3-3 3C2 grade anti-fouling coating |
| Operating Temperature | -10℃ - 50℃ (derating required above 40℃) |
| Relative Humidity | 5% - 95% (non-condensing) |
| Protection Level | IP20 (panel-mounted), IP30 (with optional protective cover) |
| Cooling Method | Forced air cooling (optimized air duct design + enlarged fan) |
| Built-in Components | Brake chopper (for models ≥1.5kW), PG card interface,
high-brightness LED operation panel |
VFD-C200 Series Model List
| Model No. | Input Specs | Output Power | Rated Output Current (A) | Control Mode | Key Features | Application Scope |
|---|
| VFD004C21A | 1-phase 220V ±15%, 50/60Hz | 0.4kW | 2.5 | Sensorless FOC/V/F | Built-in 5k-step PLC, PID, MODBUS(RS-485) | Small machinery, treadmills, small pumps |
| VFD007C21A | 1-phase 220V ±15%, 50/60Hz | 0.75kW | 4.2 | Sensorless FOC/V/F | Built-in 5k-step PLC, PID, MODBUS(RS-485) | Food packaging machines, small conveyors |
| VFD015C21A | 1-phase 220V ±15%, 50/60Hz | 1.5kW | 7.0 | Sensorless FOC/V/F | Built-in brake chopper, PLC, PID, MODBUS | Woodworking machines, small fans |
| VFD022C21A | 1-phase 220V ±15%, 50/60Hz | 2.2kW | 9.5 | Sensorless FOC/V/F | Built-in brake chopper, PLC, PID, MODBUS | Textile machines, small water pumps |
| VFD004C23A | 3-phase 220V ±15%, 50/60Hz | 0.4kW | 1.8 | Sensorless FOC/V/F | Built-in 5k-step PLC, PID, MODBUS(RS-485) | Industrial small equipment, solar pumps |
| VFD007C23A | 3-phase 220V ±15%, 50/60Hz | 0.75kW | 3.0 | Sensorless FOC/V/F | Built-in 5k-step PLC, PID, MODBUS(RS-485) | Small conveyors, packaging machinery |
| VFD015C23A | 3-phase 220V ±15%, 50/60Hz | 1.5kW | 5.0 | FOC+PG/Sensorless FOC/V/F | Built-in brake chopper, PG interface, PLC/PID | Precision woodworking machines, fans |
| VFD022C23A | 3-phase 220V ±15%, 50/60Hz | 2.2kW | 7.0 | FOC+PG/Sensorless FOC/V/F | Built-in brake chopper, PG interface, PLC/PID | Textile machines, precision conveyors |
| VFD037C23A | 3-phase 220V ±15%, 50/60Hz | 3.7kW | 11.0 | FOC+PG/Sensorless FOC/V/F | Built-in brake chopper, PG interface, PLC/PID | Medium fans, pumps, industrial conveyors |
| VFD055C23A | 3-phase 220V ±15%, 50/60Hz | 5.5kW | 16.0 | FOC+PG/Sensorless FOC/V/F | Built-in brake chopper, PG interface, PLC/PID | Large textile machines, water pumps |
| VFD075C23A | 3-phase 220V ±15%, 50/60Hz | 7.5kW | 21.0 | FOC+PG/Sensorless FOC/V/F | Built-in brake chopper, PG interface, PLC/PID | Heavy-duty fans, industrial pumps |
| VFD004C23B | 3-phase 380V ±15%, 50/60Hz | 0.4kW | 1.0 | Sensorless FOC/V/F | Built-in 5k-step PLC, PID, MODBUS(RS-485) | Industrial small equipment, solar systems |
| VFD007C23B | 3-phase 380V ±15%, 50/60Hz | 0.75kW | 1.8 | Sensorless FOC/V/F | Built-in 5k-step PLC, PID, MODBUS(RS-485) | Small machinery, packaging equipment |
| VFD015C23B | 3-phase 380V ±15%, 50/60Hz | 1.5kW | 3.0 | FOC+PG/Sensorless FOC/V/F | Built-in brake chopper, PG interface, PLC/PID | Precision machinery, small conveyors |
| VFD022C23B | 3-phase 380V ±15%, 50/60Hz | 2.2kW | 4.2 | FOC+PG/Sensorless FOC/V/F | Built-in brake chopper, PG interface, PLC/PID | Textile machines, fans, pumps |
| VFD037C23B | 3-phase 380V ±15%, 50/60Hz | 3.7kW | 7.5 | FOC+PG/Sensorless FOC/V/F | Built-in brake chopper, PG interface, PLC/PID | Industrial pumps, fans, conveyors |
| VFD055C23B | 3-phase 380V ±15%, 50/60Hz | 5.5kW | 11.0 | FOC+PG/Sensorless FOC/V/F | Built-in brake chopper, PG interface, PLC/PID | Heavy-duty machinery, water supply systems |
| VFD075C23B | 3-phase 380V ±15%, 50/60Hz | 7.5kW | 15.0 | FOC+PG/Sensorless FOC/V/F | Built-in brake chopper, PG interface, PLC/PID | Large fans, pumps, industrial production line |
Application Scope
Textile & Chemical Fiber Industry
- Ideal for spinning mills, knitting workshops, and chemical fiber
production lines worldwide
- Drives textile machines, texturing machines, and winding machines
with precise speed control
- Anti-fouling coating and optimized heat dissipation resist dust and
lint in fiber-filled environments
Food & Packaging Industry
- Widely used in food processing plants for packaging machines,
sealing machines, and conveyors
- Precise speed regulation ensures uniform packaging and reduced
material waste
- PID control stabilizes temperature and conveying rhythms for strict
process consistency
Agriculture & New Energy Sector
- Perfect match for solar water pumps in remote areas for farm
irrigation and community water supply
- Adjusts pump speed based on sunlight intensity for optimal
efficiency
- Drives ventilation fans and irrigation pumps in greenhouses with
automated management
Woodworking & Building Materials Industry
- Suitable for woodworking workshops powering engraving, cutting, and
sanding machines
- Closed-loop vector control ensures stable speed for smoother
workpieces
- Anti-fouling design enhances durability in dusty environments
General Industry & Civilian Equipment
- Used for small conveyors, fans, and oil pumps in factory automation
lines
- Energy-saving speed regulation with MODBUS or CANopen integration
- Sensorless FOC control ensures smooth speed adjustment in
treadmills and HVAC systems
Special Environment Industries
- Applicable in chemical plants and carbon fiber processing with
conductive dust and corrosive gases
- Anti-fouling coating resists corrosion and prevents circuit short
circuits
- 50℃ high-temperature resistance design for harsh working conditions
Frequently Asked Questions
Q1: I'm in North America, where the local power grid is 3-phase
480V/60Hz. Can this inverter be used directly?
No, you cannot connect it directly! The 380V model has a voltage
range of 380V±15%. Connecting to 480V will damage the internal IGBT
module. Use a step-down transformer or confirm availability of a
480V-compatible model. The inverter automatically adapts to 50/60Hz
frequency.
Q2: Installed in a chemical fiber factory with heavy dust, the
inverter often reports an "overheating" fault. How to fix it?
Clean cooling fins and fan with compressed air every 2-4 weeks.
Ensure proper ventilation with 20cm space above/below and 10cm
left/right. Consider adding a dust cover or external cooling fan
for long-term high-dust environments.
Q3: During commissioning, the motor speed fluctuates and makes a
buzzing sound. What's the problem?
Likely incorrect motor parameters or cable issues. Re-enter motor
parameters from the nameplate. For cables longer than 30 meters,
use shielded cable or add an output reactor to reduce harmonic
interference.
Q4: I want to connect the inverter to the factory's PROFIBUS-DP
control system but can't find the corresponding communication
interface. What should I do?
PROFIBUS-DP is an optional function requiring a separate
communication expansion card. Purchase the compliant version,
install with power off, enable the protocol in parameters, and
confirm compatibility with your distributor.
Q5: The inverter suddenly trips and displays "overcurrent". I
checked the lines and found no short circuit. How to troubleshoot?
Check acceleration/deceleration time settings (increase to 5-10
seconds for high-inertia loads). Verify power supply voltage
stability. Check for mechanical issues like stuck motor bearings.
Add input reactor if voltage fluctuations exceed ±15%.
Q6: I forgot to ground the inverter during installation. Can I use
it temporarily without grounding? What are the risks?
Absolutely not! Without proper grounding, the inverter may trigger
faults, create safety hazards, cause electrical interference, and
violate safety standards. Use separate grounding with resistance
less than 4Ω and wire cross-section not less than 2.5mm².
Q7: Used in high-temperature regions where ambient temperature
often exceeds 50℃, the inverter shuts down automatically. How to
handle it?
Install in cool, ventilated locations away from direct sunlight.
Clean cooling systems regularly. Consider adding external cooling
or using a larger inverter for derating. Contact distributor for
high-temperature customized models if needed.
Q8: Can one inverter control two motors? I want to link multiple
motors together.
Not recommended. Use one inverter per motor to prevent overload and
damage. For multi-motor synchronization, use individual inverters
with communication protocols or dedicated multi-motor control
models.
Q9: The inverter needs repair due to malfunction. Are there repair
centers overseas? How long is the repair cycle?
Delta has authorized repair centers in major industrial regions
worldwide. Minor repairs take 3-7 days locally, while complex
repairs requiring factory service may take 1-4 weeks depending on
location.