| Electrical Characteristics |
| Supply voltage (VDD) | Max ripple 100mVPP between 0-1MHz | 1.71 | 1.80 (3.30) | 3.60 | V | Values in parenthesis are for VDD=3.30 V. |
| Supply current (IDD) | Standby state | | 0.04 (0.5) | | A | |
| Supply current (IDD) | Continuous run mode | | 58 (61) | | A | |
| Supply current (IDD) | T and RH measurement at 1Hz | | 6.6 (7.1) | | A | |
| High-level input voltage (VIH) | | 0.7VDD | | VDD+0.5 | V | |
| Low-level input voltage (VIL) | | 0.5 | | 0.3VDD | V | |
| Low-level output current (IOL) | VOL = 0.4V | | | 3 | mA | |
| Low-level output current (IOL) | VOL = 0.6V | | | 6 | mA | |
| Temperature Sensor Characteristics |
| Temperature range (Trange) | | -40 | | 100 | C | |
| Temperature accuracy (Tacc) | TA = 0C to 70C | | 0.15 | 0.2 | C | 2 standard deviations |
| Temperature accuracy (Tacc) | TA = 40C to 100C | | | 0.3 | C | 3 standard deviations |
| Temperature resolution (Tres) | | | 0.016 | | C | |
| Response time (tresp) | T step of 10C by submersion (in 0C to 70C range); 63 % | | 1 | 1 | s | Depends on heat conductivity of the sensor PCB. |
| Temperature repeatability (Trep) | 3 of consecutive measurement values at constant conditions | -0.1 | | 0.1 | C | |
| Temperature long term drift (T) | | | 0.005 | | C/year | |
| Relative Humidity Sensor Characteristics |
| Relative humidity range (Hrange) | | 0 | | 100 | %RH | |
| Relative humidity accuracy (Hacc) | TA=25C; RH=0%RH to 85% RH; excluding hysteresis | | 2 | 3 | %RH | 2 standard deviations |
| Relative humidity accuracy (Hacc) | TA=25C; RH=>85%RH to 95% RH; excluding hysteresis | | 3 | 4 | %RH | 3 standard deviations |
| Relative humidity resolution (Hres) | | | 0.03 | | %RH | |
| Response time (tresp) | RH step of 20%RH (in 40%RH to 80%RH range); 63%; 1m/s flow; TA =
25C | | 3 | | s | |
| Relative humidity hysteresis (Hhys) | TA = 25C; RH = 20%RH to 90%RH; 2 hours exposure time | -0.55 | | 0.55 | %RH | |
| Relative humidity repeatability (Hrep) | 3 of consecutive measurement values at TA = 25C and RH = 40%RH | -0.1 | | 0.1 | %RH | |
| Relative humidity long term drift (H) | | | 0.02 | | %RH/year | |
| Absolute Maximum Ratings |
| Supply voltage (VDD) | | -0.30 | | 4.60 | V | |
| Latch-up current (Ilu) | I/O; 0.5Vdd < VI < 1.5Vdd; Tj < 125C | | | 100 | mA | |
| ESD HBM (Human body model) | all pins | | | 2000 | V | JEDEC JS-001-2014 |
| ESD CDM (Charged model device) | all pins | | | 500 | V | JEDEC JS-002-2014 |
| Storage temperature (TSTRG) | | 10 | | 50 | C | Preferably in sealed ESD bag |
| Operating ambient temperature (TA) | | 40 | | 100 | C | |
| Operating ambient relative humidity (HA) | non-condensing | 0 | | 100 | %RH | |