| Sign In | Join Free | My infospaceinc.com |
|
| Categories | Lithium Cell Grading Machine |
|---|---|
| Payment Terms: | T/T,PayPal,L/C,Western Union |
| Supply Ability: | 200 Sets/Month |
| Delivery Time: | 7~35 Days |
| Packaging Details: | Plywood Case |
| Warranty: | 1 Year Warranty With Lifetime Support |
| After-sales Service: | 24/7 Technical Support |
| Brand Name: | ACEY |
| Model Number: | ACEY-BCT5300-16P |
| Certification: | CE |
| Place of Origin: | China |
| MOQ: | 1 Set |
| Price: | USD 17700~18900/Set |
| Number of channels: | 16 Channels |
| Clamp type: | Flat head clamp (optional with crocodile clamp) |
| Clamp spacing: | 109mm |
| Working power: | Three-phase five-wire system ac380v±10%, 50hz |
| Battery voltage range: | Charge DC -0.3~4.5V; discharge DC 4.5~2V |
| Current range: | Charge DC 1000mA~300A; Discharge DC 1000mA~300A |
| Company Info. |
| Xiamen Acey New Energy Technology Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
5V 300A 16 Channels Lithium Cell Charging and Discharging Tester for Prismatic Battery Capacity Grading
Product Description
ACEY-BCT5300-16P is used to test the voltage and capacity parameters of the battery during the cell formation/charging capacity verification stage. Based on the test results, it performs classification of the batteries into the same grades, conducts data analysis, and uploads and shares the results.
Product Features
1. Each battery is independently controlled, with a separate
constant current and constant voltage source for each one, ensuring
stability and no impact. It uses a 2-channel programmable constant
current and constant voltage control module.
2. The equipment is controlled by an STM32 single-chip
microcontroller and operates in conjunction with a computer. It can
save all test data and curves, and can also be operated directly
through the device's keyboard panel. The setup process completes
the test and performs sorting.
3. Real-time detection and display of each battery's status. If
there is an anomaly, the channel will stop working and the
indicator light will illuminate.
4. It has a power-off protection function, and upon power
restoration, it can resume the original working process.
5. The power transistor uses a field-effect transistor, suitable
for batteries with lower voltage discharge, such as lithium iron
phosphate batteries, etc.
6. It has a graphical operation interface, which is clear and
intuitive. It simultaneously displays data such as battery voltage,
current, time, and capacity, and can set different colors to
indicate the corresponding working status and abnormal conditions.
7. The software is powerful and has a friendly human-machine
interface.
8. The four-wire test interface ensures high measurement accuracy.
9. The modular design concept makes it easy to maintain.
Main Technical Parameter
| Number of equipment channels | The whole machine has 16chs |
| External dimension | L112xW145xH190cm |
| Case color | Standard gray / black (customizable) |
| Clamp type | Flat head clamp (optional with crocodile clamp) |
| Clamp Spacing | 109mm |
| Channel control mode | Each channel can be started, stopped, suspended, continued and protected independently. |
| Each channel has independent constant voltage and current. Hardware control circuit | |
| The accuracy of charging current and discharging current of each channel can be calibrated automatically by software | |
| Working power supply | Three phase five wire AC380V土10%, 50Hz |
| Power factor | 0.99 @220VAC, Full Load, Grid THDu ≤2% |
| Current Harmonics | <5% @220VAC, Full Load, Grid THDu ≤2% |
| Power Section Efficiency Indicators | Charge ≥80% ,Discharge≥70% |
| Power consumption work | ≤30KW |
| Equipment failure rate | <1% |
| Power component protection function | Grid voltage overrun protection |
| Grid frequency overrun protection | |
| Heat dissipation mode | Natural wind in, upward exhaust |
| Voltage measurement range | DC-0.3~5V |
| Battery voltage range | Charge DC -0.3~4.5V; discharge DC 4.5~2V |
| Constant voltage range | DC 2~4.5V |
| Voltage accuracy | ±(0.05% reading + 0.05% full), resolution ratio 1mV |
| Voltage stability | ≤(±1mV) |
| Current range | Charge DC 1000mA~300A |
| Discharge DC 1000mA~300A | |
| Current accuracy | ±(0.05% reading + 0.05% full), resolution ratio 1mV |
| Current stability | ≤(±1mA) |
| Current rise time (90% load) | ≤50MS |
| Channel start-up time (90% load) | ≤50MS |
| Control mode | Computer control, can control the whole cabinet with scanning function |
| Communication mode | 485s port communication (port rate 57600)/ TCP |
| Process settings | Up to 32 steps and 256 cycles can be set |
| Charging mode | Constant current; constant pressure; constant current & pressure |
| Charging cut-off conditions | Voltage, current, time, capacity |
| Discharge mode | Permanent flow, constant power, constant resistance |
| Discharging cut-off conditions | Voltage, time, and capacity |
| Protection function | 1. Charging over-voltage protection, charging under-voltage protection |
| 2. Discharge over-voltage protection, discharge under-voltage protection | |
| 3. Charge and discharge voltage trend protection | |
| 4.Voltage fluctuation protection | |
| 5.Current fluctuation protection | |
| 6. Battery reverse connection protection, hardware protection mode | |
| 7. Power tube short circuit protection | |
| 8. Channel capacity alarm protection (timeout protection) | |
| 9. Voltage sampling dropout protection | |
| 10. Voltage outlier protection | |
| 11. Capacity outlier protection | |
| 12. Open voltage detection before the process starts, stop opening the channel with voltage exceeding the limit | |
| 13. Power failure protection, data breakpoint recovery | |
| Time frame | 0~3000 min / step in min |
| Time accuracy | ≤±0.1% |
| Sampling inspection cycle | 1s-60s optional |
| Battery sorting | Divide according to capacity, time, open-circuit voltage, discharge platform, etc. |
| Data processing | Can record voltage, current, time, capacity etc, automatically calculate constant current charging ratio, capacity loss, discharge efficiency, average voltage, median voltage, provide data curve and cycle diagram; can output text, excel, word or mdb format data file |
Product Display

|