ABB · TU830V1
ABB TU830V1 Extended Module Termination Unit for S800 I/O
ABB TU830V1 extended 16-channel, 50 V MTU with 2 × 16 signal
terminals, per-channel I/O and ZP connections, ModuleBus interface
and DIN-rail mounting.
TypeExtended module termination unit
SystemABB S800 I/O / System 800xA
FocusSignal, power and ZP terminals
BrandABB
TU830V1 availability, lead time and order review
Send RFQProduct Introduction
TU830V1 is an extended S800 I/O module termination unit for 16
field-signal channels and process-power connections. Each channel
has two I/O connections and one ZP connection.
Engineering note: The extended terminal layout changes the field-wiring work.
Preserve I/O, process-power and ZP identification separately before
removing the installed MTU.
Technical Specifications
Select a category to view its specifications. All categories are
closed by default.
Identification & functionView 5 specificationsHide specifications⌄
| ABB article number | 3BSE013234R1 |
|---|
| Product type | Extended Module Termination Unit (MTU) |
|---|
| System | ABB S800 I/O |
|---|
| Mounting | DIN rail |
|---|
| Primary function | Field-signal and process-power termination |
|---|
Terminal & electrical dataView 5 specificationsHide specifications⌄
| I/O channels | 16 |
|---|
| Signal terminals | 2 × 16 |
|---|
| Per-channel connections | Two I/O connections and one ZP connection |
|---|
| Rated isolation | 50 V |
|---|
| ModuleBus connection | Provided through the MTU |
|---|
Compatibility & Replacement
Confirmed family fit. ABB identifies TU830V1 as an extended MTU for S800 I/O modules.
Confirmed example. ABB product catalogs list TU830 among the permitted MTUs for DI818
and multiple 16-channel S800 input modules. Confirm the exact
active-module data sheet before installation.
Applications & Fault Scenarios
01Extended field termination
Provides more termination points than a compact MTU for 16
channels, including process-power and ZP connections.
02Panel retrofit work
Useful when the original cabinet design depends on extended local
marshalling at the I/O position.
03Field power present but no signal
Separate the signal, process-power and ZP checks; do not assume
that one healthy terminal proves the full channel path.
04Multiple adjacent channels fail
Check shared field-power distribution, terminal mapping and
I/O-module seating before replacing the controller-side module.
05Unexpected state after rewiring
Compare both I/O terminals and the ZP terminal for every affected
channel with the saved loop diagram.
AMIKON SUPPORTIndependent spare-parts support
Amikon can review the exact part number, installed system,
quantity, destination and required date before quotation.
Pre-outage checkpoints
- Identify I/O, process-power and ZP wiring independently.
- Confirm the active I/O module names TU830/TU830V1 as permitted.
- Photograph the complete 2 × 16 terminal layout.
- Recheck channel diagnostics and field power after restoration.
Amikon Supply & Service
Independent multi-brand support for maintenance, outage and
legacy-system requirements.
Order reviewPart number, quantity, destination, required date and system model
checked.
Inspection & testingLabel, condition and serial checks; testing when agreed.
Packing & dispatchProtective export packing and delivery coordination.
DOA, returns, warranty & supportAfter-sales review under the quoted return and warranty terms.
Request for Quotation
- Part Number
- Quantity
- Destination
- Required Date
- Machine / System Model
Multi-brand Spare Parts Also Requested
- S0612LSER2
- 77SN9P
- 490R-08T308E-ML
- DNMG110408-QM
- VMPA-FB-EPL-GU-P1
- ZP-MC-CG-29M8
- X34551
- 289041 H19A
- PK602HK001
- 33-0941D
- 140ACO13000
- E3T-ST13R
- 6ES7151-1AA00-0AB0
- C5-DDJNR-35060-11
- RAG151.32-D20-30
- AJ65SBTB1-16D
- CA3101E28-21SBF80A176
- 626-07-GH-P1-E4-S1
- XGI-D22A
- ABS 33c
- GLC-SX-MM-RGD 1000BASE-SX
- 140CRP93200
- A393.CG-20
- E3S-AD32
- NX-ID6142-5
- 851020-120VAC
- RM-BN7-17.000-H7SA IC908
- 40-P7X5-B1161
- CUB3R000
- TWS-LL5-G
These models are listed only as independent sourcing references.
They are not substitutes for TU830V1. Compatibility, configuration
and stock must be confirmed separately for each item.
TU830V1 FAQ
How can a buyer avoid ordering TU830 instead of ABB TU830V1?
Use the full TU830V1 model and ABB article identification from the
installed label. Do not remove the V1 suffix or rely only on
housing appearance.
What system information is useful for an ABB TU830V1 quotation?
Provide the S800 I/O module in use, system or cabinet reference,
quantity, destination, required date and clear photos of the
existing unit and terminations.
Can current stock, condition and lead time for ABB TU830V1 be
confirmed from this page?
No. Stock, condition, inspection scope and lead time change by
offer and must be confirmed in the live quotation for ABB TU830V1.
What pre-shipment evidence can I request for ABB TU830V1?
Request clear label, condition and serial-number photos plus the
agreed inspection or testing record for ABB TU830V1 before
dispatch.
How should I submit an urgent shutdown requirement for ABB TU830V1?
Send the exact part number, quantity, destination, required date,
machine or system model and failure context. Priority routing
starts after the ABB TU830V1 identity is confirmed.
What DOA, return and warranty terms apply to ABB TU830V1?
They are defined in the quotation. If ABB TU830V1 arrives DOA or
does not match the purchase order, report the serial number, label,
packaging and fault evidence promptly for after-sales review.