| Sign In | Join Free | My infospaceinc.com |
|
| Categories | Relay Protection |
|---|---|
| Model Number: | PRT-VI |
| AC Current Output Specifications: | 1. 6-phase separate output: 0~30A/phase, accuracy class 0.2 2. 3-phase output: 0~60A/phase 3. 6-phase parallel output: 0~180A 4. Continuous allowable current: 10A/phase 5. Max single-phase power: 450VA 6. Total max parallel power: 1000VA 7. Duration for 18 |
| Supply Ability: | 1000 |
| Frequency & Harmonic Index: | Fundamental frequency: 0~1000Hz Superimposable harmonics: 1~20 orders |
| Binary Output: | 4 pairs relay dry contact output DC rating: 220V / 0.2A AC rating: 220V / 0.5A |
| Delivery Time: | 5-8 workdays |
| Binary Input: | 8 channels binary input Dry contact: 1~20mA, 24V Potential contact: 0~6V=OFF; 11~250V=ON |
| Independent Auxiliary DC Power: | Two selectable levels: 110VDC / 220VDC Rated output current: 1.5A |
| MOQ: | 1 |
| AC Voltage Output Specifications: | Phase voltage: 0~120VAC/phase, accuracy class 0.2 Line voltage: 0~240VAC Power: 80VA(phase) / 100VA(line) |
| Payment Terms: | T/T |
| DC Current Output: | Range: 0~±10A per phase, accuracy class 0.5 Max load voltage: 20VDC |
| Brand Name: | HKV Test |
| Output Channel Configuration: | Standard 6 AC current channels + 6 AC voltage channels; freely combined modes: 4U3I / 6U / 6I / 12-phase |
| Company Info. |
| Wuhan HKV test Electrical Equipment Manufacturing Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
The HKVTEST Protection Relay Test Set is a professional secondary injection testing system for
commissioning, maintenance, calibration, and verification of
protective relays and power automation devices.
It provides 6-phase current and 6-phase voltage outputs, making it suitable for transformer differential, distance,
overcurrent, earth fault, generator, busbar, feeder and other
protection relay testing.
Based on DSP digital signal processing and high-fidelity linear
amplification technology, the system provides accurate and stable
waveform output for reliable relay testing in substations, power
plants, renewable energy projects, industrial power systems and
laboratories.
Contact Our
Technical Team →
| Item | Specification |
|---|---|
| Current Outputs | 6 Channels |
| Voltage Outputs | 6 Channels |
| AC Current Output | 0–30 A/phase |
| Parallel Current Output | Up to 180 A |
| AC Voltage Output | 0–120 V/phase |
| DC Current Output | ±10 A/phase |
| DC Voltage Output | ±160 V/phase |
| AC Current Accuracy | Class 0.2 |
| AC Voltage Accuracy | Class 0.2 |
| Frequency Range | 0–1000 Hz |
| Harmonic Output | Up to 20th Harmonic |
| Binary Inputs | 8 Channels |
| Binary Outputs | 4 Channels |
| Timing Measurement | 0.1 ms–9999 s |
| Auxiliary DC Supply | 110 V / 220 V Adjustable |
| Control | PC Software |
Request Technical Specifications →
Provides 6 current and 6 voltage channels, supporting flexible configurations such as 6I, 6V and 3I+4V for different relay protection tests.
High-fidelity linear amplification provides low-distortion output waveforms and stable signals for accurate relay testing.
Six independent current outputs allow convenient testing of transformer differential protection without additional current booster equipment.
PC software supports relay setting verification, automatic testing, fault simulation, harmonic testing, sequence testing, vector display, fault playback and test report generation.
Supports frequency output up to 1000 Hz and harmonic generation up to the 20th order, suitable for advanced relay testing.
Provides adjustable 110 V / 220 V DC auxiliary power for relay panels and trip/close circuits.
Compact design makes the system suitable for substation commissioning, maintenance and laboratory testing.
Start Your OEM / ODM Project →
The appropriate configuration mainly depends on:
If you are unsure which configuration you need, send us the relay type, protection function and testing requirements. Our engineers can recommend a suitable model.
Get a
Configuration Recommendation →
What is a Protection Relay Test Set used for?
It is used for secondary injection testing, commissioning, maintenance and calibration of protective relays.
What protection relays can it test?
It can test transformer differential, distance, overcurrent, earth fault, generator, busbar, feeder and other numerical protection relays.
Does it support transformer differential relay testing?
Yes. The 6-current output configuration is suitable for transformer differential protection testing.
Can it perform automatic relay testing?
Yes. The PC software supports automatic test sequences, parameter testing, fault simulation and test report generation.
Can it generate harmonics?
Yes. It supports harmonic output up to the 20th order and frequencies up to 1000 Hz.
Is OEM customization available?
Yes. HKVTEST supports OEM branding, customized configurations and
software localization.
Contact Us for
OEM / ODM →
HKVTEST is the global brand of Wuhan Hongzhi Gaocetest Electrical Technology Co., Ltd., specializing in the R&D and manufacturing of electrical
testing equipment.
With 16+ years of manufacturing experience, we provide relay protection testers, transformer testing
equipment, withstand voltage test equipment, insulation testers,
circuit breaker analyzers, cable testing systems and other
electrical diagnostic equipment.
Our products are supplied to power utilities, substations,
contractors, manufacturers and testing companies in more than 60
countries.
Send us:
Our engineers will recommend the appropriate relay test set and configuration for your application.
WhatsApp: +86 180 7153 1810
Email: fionahuang60@gmail.com
|