Sign In | Join Free | My infospaceinc.com
infospaceinc.com
Products
Search by Category
Home > Bus Parts >

3kVA UPS with 30-minute battery backup for small testing equipment

Categories Online UPS
MOQ: 1 Unit
Delivery Time: 3-5 Days
LCD: YES
Payment Terms: L/C,T/T,Western Union
Frequency Range: 40-70Hz
Harmonic Distortion: ≤3%THD (Linear Load) ≤6%THD(Non-linear Load)
Model Number: C3KS
ALARM Battery Mode: Sounding every 4 seconds
Factor: 0.9
Waveform(Batt.Mode): Pure Sinewave
Price: 300-500$ Unit
Transfer Time: Zero
Certification: CE
Weight: 7KG
Size: 397*145*220mm
Battery DC: 96V
Supply Ability: Stock
Capcity: 2700W
ALARM Overload: Sounding twice every second
Place of Origin: China
ALARM Fault: Continuously sounding
Brand Name: BLAZING POWER
ALARM Low Battery: Sounding every second
Packaging Details: Carton box
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

3kVA UPS with 30-minute battery backup for small testing equipment

3kVA UPS with 30-minute battery backup for small testing equipment

Small testing equipment may not require a large UPS, but stable and continuous power can still be important during operation. For this application, a BLAZING POWER 3kVA online UPS with a rated output power of 2700W was configured with an external battery bank and a separate battery cabinet to provide approximately 30 minutes of backup time.

Why use a 3kVA UPS?

Small testing instruments, laboratory equipment and some medical testing devices can be affected by an unexpected power interruption. If utility power fails during operation, an ongoing test may be interrupted.

For this reason, UPS sizing should consider more than the normal operating power of the equipment. Rated power, maximum power, startup characteristics and required backup time should all be checked before selecting the UPS.

For this project, a 3kVA / 2700W UPS was selected to support the connected testing equipment.

External batteries for approximately 30 minutes of backup

The application required approximately 30 minutes of battery backup, so an external battery configuration was used. The batteries are installed in a separate battery cabinet next to the UPS.

Compared with a small internal battery pack, an external battery system is more suitable when longer runtime is required. A separate cabinet also makes battery installation, wiring, inspection and future replacement more convenient.

Actual UPS runtime depends on the connected load, battery capacity, battery condition, discharge current and UPS efficiency. Therefore, the battery capacity should always be calculated according to the actual load rather than assuming that every 3kVA UPS will provide the same runtime.

Suitable for small critical loads

A 3kVA online UPS can be used with small testing equipment, laboratory instruments, monitoring systems, servers and other critical devices that should not shut down unexpectedly.

For these applications, choosing a UPS is not simply a matter of matching the “3kVA" rating. Actual load power, peak power and required backup time are the key parameters for selecting both the UPS and its battery system.

ParameterSpecification
UPS typeOnline UPS
Rated capacity3 kVA
Rated power2700 W
Power factor0.9
Battery configurationExternal battery bank
Battery installationSeparate battery cabinet
Backup timeApprox. 30 minutes*
ApplicationSmall testing equipment