| Electrical Characteristics | | | |
| Contact Resistance | IEC60512-2-1 (MILLIVOLT LEVEL METHOD) | Initially 100m MAX (NOTE2), After Test 50m MAX CHANGE | (NOTE2): CONTACT RESISTANCE INCLUDES CONDUCTOR RESISTANCE UNLESS
OTHERWISE SPECIFIED. |
| Insulation Resistance | IEC60512-3-1 | Initially 1000M MIN, After Test 100M MIN | MEASURE WITHIN 1 MINUTE AFTER APPLYING 500V DC |
| Voltage Proof | IEC60512-4-1 | No Flashover or Breakdown | AC 500Vrms Applied for 1 Minute |
| Current Leakage | | 1mA MAX | |
| Mechanical Characteristics | | | |
| Insertion and Withdrawal Force | IEC60512-6-4 | Card Insertion Force: 25 3mm/min, Card Ejection Force: 1 to 7N
(NOTE3) | (NOTE3): IT MAY BE CHANGED ACCORDING TO THE TRAY/CARD MATERIAL AND
DIMENSIONS. |
| Mechanical Operation | | Contact Resistance: After Test 50m MAX CHANGE, No Mechanical Damage
Shall Occur on the Parts. | COUNT 2 X 5,000 TIMES |
| Environmental Characteristics | | | The Test Should Be Done Under Temp 15 to 35. Air Pressure 86 to
106kPA, Relative Humidity 25 to 85%. |
| Cold | IEC60512-11-10 | No Mechanical Damage or Heavy Corrosion Shall Occur on the Parts. | Exposed at -40 For 96 Hours With Card Mated Condition |
| Dry Heat | IEC60512-11-9 | Contact Resistance: After Test 50m MAX CHANGE, Insulation
Resistance: After Test 100M MIN, No Mechanical Damage or Heavy
Corrosion Shall Occur on the Parts. | Exposed at 85 For 96 Hours With Card Mated Condition |
| Damp Heat Steady State | IEC60512-11-3 | Contact Resistance: After Test 50m MAX CHANGE, Insulation
Resistance: After Test 100M MIN, No Mechanical Damage or Heavy
Corrosion Shall Occur on the Parts. | Exposed at 40, 90 to 95%RH, 96 Hours With Card Mated Condition |
| Rapid Change of Temperature | IEC60512-11-4 | No Mechanical Damage or Heavy Corrosion Shall Occur on the Parts. | 5 Cycles (-55 To 85) With Card Mated Condition |
| Corrosion Salt Mist | IEC60068-2-11 | No Mechanical Damage or Heavy Corrosion Shall Occur on the Parts. | Exposed at 352, 5% Salt Water Spray For 48Hr |
| Vibration | IEC60512-6-3 | No Electrical Discontinuity of 1us, No Mechanical Damage Shall
Occur on the Parts., Contact Resistance After Test 50m MAX CHANGE | Frequency 10 To 55 To 10 Hz/min, Single Amplitude 0.75mm For 4h In
X,Y,Z 3 Directions, Total 12h |
| Shock | IEC60512-6-3 | No Electrical Discontinuity of 1us, No Mechanical Damage Shall
Occur on the Parts., Contact Resistance After Test 50m MAX CHANGE | Acceleration 490m/s2, Holding Time 11ms, Semi-Sine Wave For 3 Times
In 3 Directions, Total 18 Times. |
| Resistance to Soldering Heat | | No Mechanical Damage Shall Occur on the Parts. | SEE THE FOLLOWING CONDITION, NUMBER OF CYCLE 1 TIME (NOTE4) |
| General Examination | | | |
| Rating | | 0.5A, AC 10V (DC or 1000Hz) 100mA MAX | |
| Operating and Storage Conditions | | | |
| Operating Temperature Range | | -10 To 60 (With Packing) | |
| Storage Temperature Range | | -40 ~ 85 (NOTE1) | (NOTE1) : INCLUDE THE TEMPERATURE RISE BY CURRENT |
| Operating or Storage Humidity Range | | 95% MAX (Non-Condensing) | |