| Sign In | Join Free | My infospaceinc.com |
|
| Categories | Power Connectors |
|---|---|
| Model Number: | HX DC005 QT |
| MOQ: | 5 |
| Brand Name: | HX DC005 QT |
| Mounting Type: | Right Angle |
| Description: | Power Barrel Connector Jack Through Hole, Right Angle |
| Stock: | 453 |
| Connector Type: | DC Power Jack |
| Delivery Time: | 1工作日 |
| Packaging Details: | Through Hole |
| working temperature: | -25℃~+70℃ |
| Inside Contact Diameter: | 2mm |
| Rated current: | 2A |
| Rated voltage: | 30V |
| Outside Contact Diameter: | 6.3mm |
| Company Info. |
| Shenzhen ECER Network Technology Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
This document outlines the specifications for the HX DC005 QT DC socket, a component designed for electrical connections. It details electrical, mechanical, and environmental performance characteristics.
Application: Recommended for use with compatible plugs.
| Specification | Value | Unit | Condition/Notes |
|---|---|---|---|
| Rated Voltage | 30 | V DC | |
| Rated Current | 2.0 | A | |
| Contact Resistance | 50 | m MAX | |
| Insulation Resistance | 100 | M Min | |
| Withstand Voltage | 500 | V AC | (50Hz or 60Hz) |
| Mate Force | 3-30 | N | |
| Unmate Force | 3-30 | N | |
| Durability | 5000 | Cycles | |
| Temperature Range | -25 to +70 |
| Test Item | Test Condition | Specification | Notes |
|---|---|---|---|
| Contact Resistance | Measured at 1KHz small current | 0.05 | Ohm |
| Insulation Resistance | DC500V potential across terminals and frame for 1 minute | 100 | M |
| Withstand Voltage | AC500V (50/60Hz) across terminals and frame for 1 minute | No breakdown | |
| Insertion and Extraction Force | Measured with ergometer | 3-30 | N |
| Terminal Strength | 500gf static force applied to terminal top for 1 minute | No damage (mechanical and electrical) | |
| Soldering Test | Terminal top dipped 2mm in solder bath at 2305 for 3sec | ||
| Durability (Life Test) | 5000 cycles at a rate of 10-20 cycles per minute (unloading) | Contact Resistance 40m, Drive Force 3-30N (initial value) | |
| Heat Test | 802 for 48 hours, then kept in normal condition for 30 minutes | Contact Resistance 50m, Insulation Resistance 100M, No mechanical/electrical damage | |
| Humidity Test | 402 and 90-95% RH for 48 hours, then kept in normal condition for 30 minutes | ||
| Cold Test | -252 for 48 hours, then kept in normal condition for 30 minutes |
|