| Voltage Rating | 400 volts AC/DC | |
| Current Rating | 3 amperes | |
| Temperature Rating | -40 to 130C | |
| Low Level Contact Resistance (LLCR) | 10 milliohms maximum initial. 20 milliohms maximum final. | EIA-364-23. Subject specimens to 100 milliamperes maximum and 20
millivolts maximum open circuit voltage. See Figure 1. |
| Insulation Resistance | 1000 megohms minimum initial. 500 megohms minimum final. | EIA-364-21. 500 10% volts DC, 2 minute hold. Test between adjacent
contacts. |
| Withstanding Voltage | One minute hold with no breakdown or flashover. | EIA-364-20, Condition I. 1800 volts AC at sea level. Test between
adjacent contacts. |
| Temperature Rise vs. Current | 30C maximum temperature rise at specified current. | EIA-364-70, Method 1. Stabilize at a single current level until 3
readings at 5 minute intervals are within 1C. See Figure 2. |
| Solderability, SMT test | Solderable area shall have a minimum of 95% solder coverage. | J-STD_002D,Test S1 Subject contacts to solderability. |
| Random Vibration (Office) | No discontinuities of 1 microsecond or longer duration. | EIA-364-28, Test Condition VII, Test Condition Letter D. Subject
mated specimens to 3.10 G's rms between 20 to 500 Hz. Fifteen
minutes in each of 3 mutually perpendicular planes. See Figure 3. |
| Mechanical Shock (Office) | No discontinuities of 1 microsecond or longer duration. | EIA-364-27, Test Condition H. Subject mated specimens to 30 G's
half-sine shock pulses of 11 milliseconds duration. Three shocks in
each direction applied along 3 mutually perpendicular planes, 18
total shocks. See Figure 3. |
| Durability | Shall meet visual requirements, show no physical damage, and meet
requirements of additional tests as specified in the Product
Qualification and Requalification Test Sequence. | EIA-364-9. Mate and unmate specimens for 5 cycles at a maximum rate
of 500 cycles per hour. |
| Mating Force | 45 N [10.11 lbf] max | EIA-364-13, Method A. Measure force necessary to mate specimens at
a maximum rate of 12.7 mm per minute. |
| Unmating Force | 4 N [0.8992 lbf] min | EIA-364-13, Method A. Measure force necessary to unmate specimens
at a maximum rate of 12.7 mm per minute. |
| Thermal Shock | Shall meet visual requirements, show no physical damage, and meet
requirements of additional tests as specified in the Product
Qualification and Requalification Test Sequence. | EIA-364-32, Method A, Test Condition I, Test Duration A. Subject
specimens to 5 cycles between -40 and 130C with 30 minute dwells at
temperature extremes and 1 minute maximum transition between
temperatures. |
| Humidity/Temperature Cycling | Shall meet visual requirements, show no physical damage, and meet
requirements of additional tests as specified in the Product
Qualification and Requalification Test Sequence. | EIA-364-31, Method IV. Subject specimens to 10 cycles (10 days)
between 25 and 65C at 80 to 100% RH with -10C cold shock. |
| Temperature Life | Shall meet visual requirements, show no physical damage, and meet
requirements of additional tests as specified in the Product
Qualification and Requalification Test Sequence. | EIA-364-17, Method A, Test Condition 4, Test Time Condition B.
Subject mated specimens to 130C for 500 hours. |