Sign In | Join Free | My infospaceinc.com
infospaceinc.com
Products
Search by Category
Home > Vacuum Equipment >

Automatic Helium Leak Testing Machine Delivering Low False Alarm for Compressor Inspection

Categories Helium Leak Testing Equipment
Model Number: HC-HLT-800
Test Cycle: 10 s/pc, up to 5 s/pc
MOQ: 1 set
Delivery Time: 90 working days
Test Stations: 2 (each station tests 2 workpieces)
Fixture Seal Verification: System checks fixture seal first
Payment Terms: L/C,T/T
Brand Name: HongCe
Packaging Details: Plywood
Price: Negotiation
Supply Ability: 1 set per 3 months
Control System: PLC with 7-inch touch
Minimum Detectable Leak: 1.0E-8 Pa.m3/s
Place of Origin: China
Alarm Rate Control: Background suppression with temperature compensation
Certification: Calibration certificate(cost additional)
Tracer Gas: Helium 99.999%
Detection Method: Helium mass spectrometry, vacuum mode
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Automatic Helium Leak Testing Machine Delivering Low False Alarm for Compressor Inspection

Automatic Helium Leak Testing Machine for Compressor Inspection

On a running compressor line, a false alarm is never a small event. Every good unit rejected by an unstable leak test is pulled for rework, retested and returned to the line, while the operator slowly stops trusting the test station. The HongCe HC-HLT-800 was developed around one practical goal: a result that production and quality teams can rely on the first time.

Why false alarms happen in helium leak testing

Most false alarms come from the environment and the process rather than from real leaks: background helium in the workshop air, temperature drift inside the vacuum chamber, tracer gas left over from the previous cycle, and worn fixture seals. A very sensitive detector will faithfully report all of these as failures unless the system is designed to separate them from the part itself.

How the HC-HLT-800 keeps the alarm rate low

  • Dual-chamber isolation: the detection volume is separated from ambient air so workshop helium does not reach the sensor.
  • Temperature compensation: the baseline is corrected as the chamber warms, keeping readings stable across a full shift.
  • Automatic cycle purge: residual tracer gas is cleared before the next part is loaded.
  • Fixture seal verification: the system checks the fixture seal first and reports a sealing problem instead of blaming the part.

Technical specifications

ItemSpecification
Detection methodHelium mass spectrometry, vacuum mode
Minimum detectable leak1.0E-8 Pa.m3/s
Test stations2 (each station tests 2 workpieces)
Test cycle10 s/pc, up to 5 s/pc
Tracer gasHelium 99.999%
Control systemPLC with 10-inch HMI

Typical applications

The system is used for compressor shells, receivers, accumulators, heat exchangers and other sealed metal components where a dependable pass or fail decision matters more than raw sensitivity alone.

Engineering and service support

HongCe has supplied helium leak test systems to compressor and refrigeration manufacturers for more than fifteen years. Every machine is factory acceptance tested with certified helium leak standards before shipment, and our engineers support installation, operator training and calibration both on site and remotely. Spare parts and a documented calibration procedure are provided with each system.

Frequently asked questions

What leak rate can you guarantee? The standard configuration resolves 1.0E-8 Pa.m3/s; tighter targets can be discussed for specific parts.

Can the machine test parts of different sizes? Yes. The fixture can be configured for several workpiece families, and the sealing check protects the result when a part is loaded incorrectly.

Request a configuration

Send us your workpiece drawing, target leak rate and required cycle time, and our engineers will propose a configuration together with an expected false alarm performance for your process.

Buy Automatic Helium Leak Testing Machine Delivering Low False Alarm for Compressor Inspection at wholesale prices
Send your message to this supplier
 
*From:
*To: Guangzhou HongCe Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0