| MECHANICAL | CONNECTION FORCE | MEASUREMENT SHALL BE MADE AFTER CONNECTING AND DISCONNECTING USING
STANDARD PLUG GAUGE 3 TIMES. | DISCONNECTI O FORCE | 0.5~2.0Kgf |
| TERMINAL STRENGTH | A STATIC LOAD OF 0.1N/m(1kgf/cm)SHALL BE APPLIED TO THE TIP OF THE
TERMINAL FOR 1 MIN IN ANY DIRECTION | PERFORMANCE | THERE SHALL BE NO DAMAGE TO THE TERMINAL SUCH AS CRACKS, LOOSENESS
OR PLAY ELECTRICAL ,AND MECHANICAL CHARACTERISTICS SHALL BE
SATISFIED |
| ELECTRICAL | CONTACT RESISTANCE | MEASURED AT SMALL CURRENT 100mA OR LESS 1000Hz | PERFORMANCE | 40m MAX |
| INSULATION RESISTANCE | APPLYA VOLTAGE OF 100V DC FOR 1 MIN TO FOLLOWING PORTIONS AFTER
WHICH MEASUREMENT SHALL BE MADE: (1) BETWEEN BODY AND CONDUCTOR (2)
BETWEEN CONDUCTORS NOT TO BE CONTACT (3) BETWEEN CONDUCTORS NOT TO
BE CONTACT WHEN PLUG IS INSERTED | PERFORMANCE | 100M MIN |
| DIELECTRIC STRENGTH | AC 100V ims(50~60Hz)FOR 1 MIN TRIP CURRENT:0.5mA (1) BETWEEN BODY
AND CONDUCTOR (2) BETWEEN CONDUCTORS NOT TO BE CONTACL (3) BETWEEN
CONDUCTORS NOT TO BE CONTACT WHEN PLUG IS INSERTED | PERFORMANCE | WITHOUT DAMAGE TO PARTS ARCING OR BREAKDOWN ETC |
| DURABILITY | SOLDERABILITY TEST | THE TOP OF THE TERMINALS SHALL BE DIPPED 1mm IN THE SOLDER BATH OF
2505FOR 50.5 SECONDS | (1) SOLDER WETTING TIME SHALL BE 3 SEC OR LESS (2) THE AREA OF
SOLDERING SHOULD BE OVER 75% | |
| RESISTANCE TO SOLDERING HEAT TEST (REFLOW) | PREHEAT:TEMPERATURE ON THE COPPER FOIL SURFACE SHOULD REACH
180.120S AFTER THE P.C.B ENTERED INTO THE SOLDERING EQUIPMENT.
TALLEST TEMPERATURE:TEMPERATURE ON THE COPPER FOIL SURFACE SHOULD
REACH THE PEAK TEMPERATURE OF 2605WITH IN 20 SECONDS. | PERFORMANCE | WITHOUT DEFOR MATION OF CASE OR EXCESSIVE LOOSENESS OF TEMINALS
ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED |
| RESISTANCE TO SOLDERING HEAT TEST (SOLDERING IRON) | BIT TEMPERATURE 3305 APPLICATION TIME OF SOLDERING IRON30.5 SEC
HOWEVER EXCESSIVE PRESSURE SHALL NOT BE APPLIED TO THE TERMINAL | PERFORMANCE | WITHOUT DEFOR MATION OF CASE OR EXCESSIVE LOOSENESS OF TEMINALS
ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED |
| HUMIDITY TEST | THE JACK SHALL BE STORED ATA TEMPERATURE OF 402AND A HUMIDITY OF
90%TO 96% FOR 96 Hr,THEN THE JACK SHALL BE MAINTAINED AT STANDARD
ATMOSPHERIC CONDITION FOR 1 Hr FOR OTHER PROCEDURES | PERFORMANCE | THERE SHALL BE NO DAMAGE ON APPEARANCE MECHANICAL AND ELECTRICAL
CHARACTERISTICS SHALL BE SATISFIED |
| HEAT TEST | THE JACK SHALL BE STORED ATA TEMPERATURE OF702FOR 96 HOURS AND THEN
IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY MBASURBM | PERFORMANCE | THERE SHALL BE NO DAMAGE ON APPEARANCE MECHANICAL AND ELECTRICAL
CHARACTERISTICS SHALL BE SATISFIED |
| COLD TEST | THE JACK SHALL BE STORED ATA TEMPERATURE OF-253FOR 96 HOURS AND
THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY CONDITIONS
FOR 1 HOUR AFTER WHICH | PERFORMANCE | THERE SHALL BE NO DAMAGE ON APPEARANCE MECHANICAL AND ELECTRICAL
CHARACTERISTICS SHALL BE SATISFIED |
| LIFE TEST (WITHOUT LOAD) | CONNECTION AND DISCONNECTION SHALL BE MADE WITH THE MATING PLUGS
AND JACKS FOR 5000 CYCLES AT A SPEED OF 10 TO 25 CYCLES/MIN | (1) CONTACT RESISTANCE SHALL BE 0.1 (2) DISCONNECTION FORCE SHALL
BE 0.8 TO 2.0N (3) MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL
BE SATISFIED | |
| LIFE TEST (WITH LOAD) | CONNECTION AND DISCONNECTION SHALL BE MADE 5000 CYCLES AT A SPEED
10 TO 20 CYCLES / MIN LOAD AT RATING CONDITION NON-INDUCTIVE LOAD | (1) CONTACT RESISTANCE SHALL BE 0.1 (2) DISCONNECTION FORCE SHALL
BE 0.8 TO 2.0N (3) MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL
BE SATISFIED | |
| TEMPARATURE CYCLING TEST | THE JACK SHALL BE SUB JECTED TO 5 CYCLES OF THE FOLLOWING
CONDITIONS SHOWED IN THE FIGURE,AND THEN SHALL RETURNED ALLOWED TO
REMAIN IN ROOM AMBIENT CONDITION FOR 30 MINUTES | INSERTION EXTRACTION FORCE:3 TO 20N CONTACT RESISTANCE:MAX.30M
INSULATION RESISTANCE: MIN.100 M DIELECTRIC WITHSTANDING VOLTAGE:
100VAC/MIN(BETWEEN TERMINALS) | PRODUCT CANNOT BE DEFORMED OR BROKEN |
| COLD&HEAT SHOCK TEST | THEJACKSHALLBESUBJECTEDTO5CYCLESOF THEFOLLOWINGCONDITIONSSHOWED
INTHE FIGURE,AND THEN SHALL RETURNED AND ALLOWED
TOREMAININROOMAMBIENTCONDITIONFOR 30MINUTES | INSERTION EXTRACTION FORCE:3 TO 25N CONTACT RESISTANCE:MAX.30M
INSULATION RESISTANCE: MIN.100 M DIELECTRIC WITHSTANDING VOLTAGE:
500VAC/MIN(BETWEEN TERMINALS) | PRODUCT CANNOT BE DEFORMED OR BROKEN |