| Ratings |
| Rated Voltage (MAX) | | 50V |
| Rated Current (MAX) | [AC/DC (effective value) 50Hz] | 0.5A |
| Ambient Temperature Range | | -25 +85 |
| Electrical Performance |
| Contact Resistance | Mate applicable FPC/FFC, measure by dry circuit, 20mV MAX, 10mA | 20 m MAX |
| Insulation Resistance | Mate applicable FPC/FFC, apply 500V DC between adjacent terminal or
ground | 500 M MIN |
| Dielectric Strength | Mate applicable FPC/FFC, apply 200V AC (virtual value) for 1 minute
between adjacent terminal or ground | No Breakdown |
| Mechanical Performance |
| Locking and Withdrawal Force | Locking | 1.96*n (N) MAX |
| Withdrawal | 0.49*n (N) MIN |
| Terminal / Housing Retention Force | Pull the terminal at the speed rate of 253mm per minute | 3.92N MIN |
| Environmental Performance and Others |
| Repeated Insertion and Withdrawal | Actuator up to 20 cycles at the speed rate of less than 10
cycles/minute | |
| Contact Resistance | 60 m MAX |
| Temperature Rise | Carrying rated current load (UL 498) | |
| Temperature Rise | 30 MAX |
| Vibration | DC 1mA energized, Amplitude: 1.5mm P-P, Sweep time: 10-55-10Hz/min,
Duration: 2 hours in each X,Y,Z axes | |
| Discontinuity | 1 ms MAX |
| Shock | DC 1mA energized, 490m/s {50G}, 3 strokes in each X,Y,Z axes | |
| Discontinuity | 1 ms MAX |
| Heat Resistance | Mate FPC/FFC, 852 in air for 96 hours, then return to room
temperature for 1-2 hours | |
| Contact Resistance | 60 m MAX |
| Cold Resistance | Mate FPC/FFC, -402 in air for 96 hours, then return to room
temperature for 1-2 hours | |
| Contact Resistance | 60 m MAX |
| Humidity | Mate FPC/FFC, 402, 90-95% RH for 96 hours, then measure within 0.5
hours at room temperature | |
| Insulation Resistance | 20 M MIN |
| Temperature Cycling | 5 cycles of: a) -553 30 minutes; b) 852 30 minutes; with 10-15
minutes at room temp/humidity between cycles | |
| Contact Resistance | 60 m MAX |
| Salt Spray | Mate FPC/FFC, 484 hours exposure to a salt spray from 51% solution
at 352. Rinse with water and dry at room temperature after test. | |
| Contact Resistance | 60 m MAX |
| SO2 Gas Resistance | Mate FPC/FFC, 24 hours exposure to 505ppm SO2 gas at 402 | |
| Contact Resistance | 60 m MAX |
| NH3 Gas Resistance | Mate FPC/FFC, 40 minutes exposure to NH3 gas evaporating from 28%
Ammonia solution | |
| Contact Resistance | 60 m MAX |
| Solderability | Soldering Time: 20.5 sec. Soldering Temperature: 2355. 0.2 mm from
terminal tip | |
| Solder Wetting | 95% coverage |
| Resistance to Soldering Heat | Soldering Time: 50.5 sec. Soldering Temperature: 2605. 0.2 mm from
terminal tip | |
| Appearance | No Damage, Deformation |