| Mechanical | | | |
| Connection Force | Measured after connecting and disconnecting using standard plug
gauge 3 times. | 3.75 | kgf |
| Disconnection Force | Measured after connecting and disconnecting using standard plug
gauge 3 times. | 1.02 | kgf |
| Terminal Strength | A static load of 0.1N/m (1kgf/cm) shall be applied to the tip of
the terminal for 1 min in any direction. There shall be no damage
to the terminal such as cracks, looseness or play. Electrical, and
mechanical characteristics shall be satisfied. | - | - |
| Electrical | | | |
| Contact Resistance | Measured at small current (100mA or less), 1000Hz. | 30 | m |
| Insulation Resistance | Apply a voltage of 100V DC for 1 min to following portions: (1)
Between body and conductor (2) Between conductors not to be contact
(3) Between conductors not to be when plug is inserted. | 1000 | M |
| Dielectric Strength | AC 500V rms (50~60Hz) for 1 min. Trip current: 0.5mA. (1) Between
body and conductor (2) Between conductors not to be contact (3)
Between conductors not to be when plug is inserted. Without damage
to parts arcing or breakdown etc. | 500 | VAC/min |
| Durability | | | |
| Solderability Test | Terminals dipped 1mm in solder bath of 2305 for 50.5 seconds. (1)
Solder wetting time shall be 3 sec or less. (2) The area of
soldering should be over 75%. | - | - |
| Resistance to Soldering Heat Test (Reflow) | Preheat: 180, 120s. Peak Temp: 2305 within 20 seconds. Without
deformation of case or excessive looseness of terminals. Electrical
characteristics shall be satisfied. | - | - |
| Resistance to Soldering Heat Test (Soldering Iron) | Bit Temperature 3305. Application time 30.5 sec. However, excessive
pressure shall not be applied to the terminal. Without deformation
of case or excessive looseness of terminals. Electrical
characteristics shall be satisfied. | - | - |
| Humidity Test | Stored at 402 and 90%~96% humidity for 96 Hr, then maintained at
standard atmospheric condition for 1 Hr. | - | - |
| Heat Test | Stored at 702 for 96 hours, then subjected to controlled recovery
for 1 hour. No damage on appearance. Mechanical and electrical
characteristics shall be satisfied. | - | - |
| Cold Test | Stored at -253 for 96 hours, then subjected to controlled recovery
for 1 hour. No damage on appearance. Mechanical and electrical
characteristics shall be satisfied. | - | - |
| Life Test (No Load) | Connection and disconnection for 5,000 cycles at a speed of 10 to
25 cycles/min. | 5000 | Cycles |
| Life Test (Load) | At rating condition (non-inductive load). Connection and
disconnection for 1,000 cycles at a speed of 10 to 20 cycles/min.
(1) Contact Resistance 0.1 (2) Disconnection Force 0.8 to 2.0N (3)
Mechanical and electrical characteristics shall be satisfied. | 1000 | Cycles |
| Temperature Cycling Test | 5 cycles of specified conditions, then 30 minutes in room ambient.
No deformation or cracks. Insertion & Extraction Force: 3 to 20N.
Contact Resistance: Max.30m. Insulation Resistance: Min.100 M.
Dielectric Withstanding Voltage: 100VAC/min (between terminals). | - | - |
| Cold & Heat Shock Test | 5 cycles of specified conditions, then 30 minutes in room ambient.
No deformation or cracks. Insertion & Extraction Force: 3 to 25N.
Contact Resistance: Max.30m. Insulation Resistance: Min.100 M.
Dielectric Withstanding Voltage: 500VAC/min (between terminals). | - | - |