| MECHANICAL | CONNECTION FORCE | Measurement shall be made after connecting and disconnecting using
standard plug gauge 3 times. | 0.5~2.0Kgf |
| DISCONNECTION FORCE | Measurement shall be made after connecting and disconnecting using
standard plug gauge 3 times. | 0.8~2.0Kgf |
| TERMINAL STRENGTH | A static load of 0.1N/m(1kgf/cm) shall be applied to the tip of the
terminal for 1 min in any direction. There shall be no damage to
the terminal such as cracks, looseness or play. Electrical, and
mechanical characteristics shall be satisfied. | N/A |
| ELECTRICAL | CONTACT RESISTANCE | Measured at small current (100mA or less) 1000Hz. | 40m |
| INSULATION RESISTANCE | Apply a voltage of 100V DC for 1 min to following portions after
which measurement shall be made: (1) Between body and conductor (2)
Between conductors not to be contact (3) Between conductors not to
be when plug is inserted. | 100M |
| DIELECTRIC STRENGTH | AC 100V ims(50~60Hz) for 1 min trip current: 0.5mA. (1) Between
body and conductor (2) Between conductors not to be contact (3)
Between conductors not to be when plug is inserted. | Without damage to parts arcing or breakdown etc. |
| DURABILITY | SOLDERABILITY TEST | The top of the terminals shall be dipped 1mm in the solder bath of
2505 for 50.5 seconds. | (1) Solder wetting time shall be 3 seconds or less. (2) The area of
soldering should be over 75%. |
| RESISTANCE TO SOLDERING HEAT TEST (Reflow Soldering) | Preheat: Temperature on the copper foil surface should reach 180.
Tallest temperature: Temperature on the copper foil surface should
reach the peak temperature of 2605 within 20 seconds. | Without deformation of case or excessive looseness of terminals.
Electrical characteristics shall be satisfied. |
| RESISTANCE TO SOLDERING HEAT TEST (Soldering Iron Method) | Bit temperature 3305. Application time of soldering iron 30.5
seconds. However, excessive pressure shall not be applied to the
terminal. | Without deformation of case or excessive looseness of terminals.
Electrical characteristics shall be satisfied. |
| HUMIDITY TEST | The jack shall be stored at a temperature of 402 and a humidity of
90% to 96% for 96 Hr, then the jack shall be maintained at standard
atmospheric condition for 1 Hr. | N/A |
| HEAT TEST | The jack shall be stored at a temperature of 702 for 96 hours, and
then it shall be subjected to controlled recovery. | There shall be no damage on appearance. Mechanical and electrical
characteristics shall be satisfied. |
| COLD TEST | The jack shall be stored at a temperature of -253 for 96 hours and
then it shall be subjected to controlled recovery conditions for 1
hour. | There shall be no damage on appearance. Mechanical and electrical
characteristics shall be satisfied. |
| LIFE TEST (Without Load) | Connection and disconnection shall be made with the mating plugs
and jacks for 5000 cycles at a speed of 10 to 25 cycles/min. | N/A |
| LIFE TEST (Load) | At rating condition (non-inductive load). Connection and
disconnection shall be made 5000 cycles at a speed 10 to 20
cycles/min. | (1) Contact resistance shall be 0.1. (2) Disconnection force shall
be 0.8 to 2.0N. (3) Mechanical and electrical characteristics shall
be satisfied. |
| TEMPERATURE CYCLING TEST | The jack shall be subjected to 5 cycles of specified conditions,
then returned to room ambient condition for 30 minutes. | No deformation or cracks in molded part. Insertion & Extraction
Force: 3 to 20N. Contact Resistance: Max. 30m. Insulation
Resistance: Min. 100 M. Dielectric Withstanding Voltage: 100VAC/min
(between terminals). |
| COLD & HEAT SHOCK TEST | The jack shall be subjected to 5 cycles of specified conditions,
then returned to room ambient condition for 30 minutes. | No deformation or cracks in molded part. Insertion & Extraction
Force: 3 to 25N. Contact Resistance: Max. 30m. Insulation
Resistance: Min. 100 M. Dielectric Withstanding Voltage: 500VAC/min