| 1 - RATING | | DC50V 1A | | |
| 2 - OPERATING TEMPERATURE RANGE | | -20C~70C | PRESERVATIVE TEMPERATURE RANGE: 15C~35C | |
| 3 - ELECTRICAL PERFORMANCE | 3A | RESISTANCE | | SUCCESSIVE MEASUREMENTS. MEASURED BY THE CONTACT RESISTANCE
APPARATUS OR CONTACT METER AT 0.1A DC5V. THE RESULT IS THE AVERAGE
OF 5 MEASUREMENTS. | 70m max |
| 3B | INSULATION RESISTANCE | BETWEEN TERMINALS, BETWEEN INDIVIDUAL TERMINALS AND FRAME | A VOLTAGE OF 250V DC SHALL BE APPLIED FOR 1 MIN. AFTER WHICH
MEASUREMENT SHALL BE MADE. | 100M min |
| 3C | DIELECTRIC STRENGTH | BETWEEN TERMINALS, BETWEEN INDIVIDUAL TERMINALS AND FRAME | A VOLTAGE OF 250V AC SHALL BE APPLIED FOR 1 MIN. AFTER WHICH
MEASUREMENT SHALL BE MADE. | WITHOUT DAMAGE TO PARTS, ARCING OR BREAKDOWN ETC. |
| 3D | INSERTION AND EXTRACTION FORCE | APPLY TO THE APENDED DRAWING. | | 3-40N |
| 4 - MECHANICAL PERFORMANCE | 4A | INSERTION AND EXTRACTION FORCE | Being measured at across spring piece and across matching plug for
ergometer | | 3-40N |
| 4B | TERMINAL STRENGTH | THE TERMINALS FOR 60 SEC. IN ANY DIRECTION | A STATIC LOAD OF 10 N(1000gf) SHALL BE APPLIED TO THE TIP OF THE
TERMINAL. | WITHOUT DAMAGE OR EXCESSIVE LOOSENESS OF ACTUATOR. |
| 4C | STANDARD ATMOSPHERIC CONDITIONS | | AMBIENT TEMPERATURE: 15C TO 35C, RELATIVE HUMIDITY: 25% TO 75%RH,
AIR PRESSURE: 80Kpa TO 106Kpa | |
| 5 - DURABILITY | 5A | SOLDERING | | Wave-soldering: 260 +/-5C within 3 seconds. Hand welding: 380C or
below within 3 seconds. | WITHOUT DEFORMATION OF CASE, RESISTANCE OR EXCESSIVE LOOSENESS OF
TERMINALS. |
| 5B | LIFE TEST | | AN ACTUATOR SHALL BE SUBJECT TO 5000 CYCLES AT A SPEED OF 30 CYCLES
FOR 1 MIN. | ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED. |
| 5C | HEAT TEST | | 852C for 48 hours, then keep in normal condition for 30 minutes. | APPEARANCE, MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE
SATISFIED. |
| 5D | HUMIDITY TEST | | 402C 90-96%RH for 48 hours, test after keeping in normal condition
for 30 min. | APPEARANCE, MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE
SATISFIED. |
| 5E | COLD TEST | | -402C for 48 hrs. After test keep in normal condition for 30 min. | APPEARANCE, MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE
SATISFIED. |
| 5F | SALT SPRAY TEST | | 5% NaCl liquor for 24 hours, after washing. Keep in normal
condition for 30 min. | WITHOUT EXCESSIVE CORROSION OR CRACK. |