| Sign In | Join Free | My infospaceinc.com |
|
| Categories | Gas Sensor |
|---|---|
| Price: | Negotiable |
| Packaging Details: | Standard Package |
| Model Number: | O2S-FR-T2-18BM-C |
| Oxygen partial pressure range: | 2–3000 mbar |
| Supply Ability: | 1000pcs/Month |
| Payment Terms: | L/C, D/A, D/P, T/T, |
| Delivery Time: | 3-5Workingdays |
| Place of Origin: | UK |
| Accuracy after calibration: | ±0.5% O2 |
| Brand Name: | SST |
| Oxygen concentration measurement range: | 0.1%–100% vol O2 |
| MOQ: | 1 |
| Resolution: | 0.01% O2 |
| Company Info. |
| ShenzhenYijiajie Electronic Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
O2S-FR-T2-18BM-C Oxygen Sensor Probe Rapid Response Type Analog output
Operating Principles and Features (Distinguishing it from the 4OX-V electrochemical oxygen sensor)
1. Uses a non-consumable zirconia element with an exceptionally
long service life (5–10 years); unlike electrochemical sensors, it
does not fail due to electrolyte dry-out.
2. Requires no reference gas; a single-point calibration in fresh
air (20.7% O₂) is sufficient.
3. Immune to interference from temperature, humidity, or minor
fluctuations in atmospheric pressure; offers outstanding stability
in harsh flue gas environments.
4. Relies on a built-in high-frequency oxygen pump to cyclically
draw gas into and out of the chamber, calculating oxygen
concentration based on pump cycles; delivers excellent linearity.
Specification:
| Operating voltage | 4.35 VDC ±0.1 V; current: 1.85 A |
| Standby/thermal maintenance | 2 VDC, 0.85 A (intermittent power-saving mode) |
| Pump body impedance at 700°C | <6 kΩ |
| Gas flow velocity tolerance | 0–10 m/s |

|