1. Application
Needle flame testing equipment is suitable for the research,
production and quality inspection departments of lighting,
low-voltage electrical appliances, household appliances, machine
tools, electrical machines, motors, power tools, electronic
instruments, electrical instruments, information technology
equipment, electrical business equipment, electrical connectors,
accessories and other electronic equipment and its components,
construction plastics or other solid combustible materials
industry. The design meets the requirements of GB/T5169.5-2008
"Fire hazard test for electrical and electronic products Part 5
Test flame needle flame test method device, confirmation test
method and guide" and other standards. It has the characteristics
of reasonable structure, accurate control and simple operation.
2. Standards
| GB/T5169.5-2008 |
3. Main Technical Parameters
(1) Needle shaped burner: outer diameter less than 0.9 mm, height
at least 35 mm, pore size 0.5mm±0.1mm.
(2) Flame height: 12mm±1mm.
(3) Flame angle: 0 degree, 45 degree adjustable.
(4) Specification of temperature measuring copper block: diameter
is 4 mm (±0.01 mm), length is 6 mm (±0.03 mm), weight is 0.58
(±0.01 g), material is copper
(5) Check time: 23.5s±1.0s
Needle Flame Testing Machine,Needle flame burning test machine,Material Needle Flame Tester with Touch Screen
(6) The temperature range of the flame temperature sensor is
greater than or equal to 1050℃.
(7) Flame time: 5S, 10s, 20s, 30s, 60s, 120s; error is ±0.1s;
digital display can be preset.
(8) Holding time: 1s ~ 999.9s (digital display, manual suspension
to maintain digital display).
(9) Temperature gradient of gas flame: (100℃±5℃) ~ (700℃±3℃), the
time required to increase the temperature from 100℃ to 700℃ is
23.5s.
(10) Imported K type armored thermocouple and stainless steel pipe
with diameter of 0.5 mm diameter as sheath.
(11) The test chamber: ≥ 0.5 m3, the background is black, and the
material is stainless steel.
The specific size of the test chamber is L1130 x W630 x H1305 mm.
(12) Working voltage: AC220V±10V/50HZ




|