and its technical items, and generated a complete testing report.
| Sign In | Join Free | My infospaceinc.com |
|
| Categories | Battery Testing Equipment |
|---|---|
| MOQ: | 1 |
| Place of Origin: | Guangdong, China |
| Application: | Battery Testing |
| power: | / |
| Function 7: | Total voltage under-pressure protection and recover test |
| Protection Class: | IP65 |
| Accuracy: | 0.01 |
| customized support: | OEM, ODM |
| Function 5: | Cell under-voltage protection and recover test |
| Capacity: | 16~24S 100A/200A/300A |
| Function 1: | OCV test |
| Function 9: | Charge and discharge over-current protection and recover test |
| Type: | Testing Machine |
| Function 3: | Sleep power test |
| Function 4: | Cell over-voltage protection and recover test |
| Brand Name: | HAIDA |
| Function 6: | Total voltage over-voltage protection and recover test |
| warranty: | 1 |
| Voltage: | / |
| Function 2: | Normal power consumption test |
| Function 8: | Balance voltage and current test |
| Company Info. |
| Haida Equipment Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |



Models | ||||||
HD-H219 Capacity: 16~24S 100A/200A/300A | ||||||
Pack Voltage | ||||||
Items | Parameters | Accuracy | Resolution | |||
Voltage Measurement | 5-180V | 0.1% F.S | 1mV | |||
Simulated battery output | ||||||
Items | Parameters | Accuracy | Resolution | |||
Voltage range | 100-5000 mV | 0.01%R.D ± 0.02% F.S | 0.1mV | |||
uA current | 1-5000uA | 0.01%R.D ± 0.1% F.S | 0.1uA | |||
mA current | 1-3000mA | 0.01%R.D ± 0.1% F.S | 0.1mA | |||
Simulated battery sampling | ||||||
Items | Parameters | Accuracy | Resolution | |||
Voltage range | 100-5000mV | 0.01%R.D ± 0.02% F.S | 0.1mV | |||
uA current | 1-5000uA | 0.01%R.D ± 0.1% F.S | 0.1uA | |||
mA current | 1-3000mA | 0.01%R.D ± 0.1% F.S | 0.1mA | |||
Simulated battery's ability of absorbs current | ||||||
Items | Parameters | Accuracy | Resolution | |||
Current range | 1-3000mA | 0.01%R.D ± 0.1% F.S | 0.1mA | |||
Temperature simulation | ||||||
Items | Parameters | Accuracy | Resolution | |||
Temperature range | -50℃~+300℃ | 0.1%R.D ± 3% F.S | 0.1℃ | |||
High precision constant current source | ||||||
Items | Parameters | Accuracy | Resolution | |||
Voltage range | 1-5V | 0.1%FS | 0.1mV | |||
Charge current | 1-300A | 0.05%RD±0.05%FS | 0.1uA | |||
Discharge current | 1-300A | 0.05%RD±0.05%FS | 0.1mA | |||
Recharger | ||||||
Items | Parameters | Accuracy | Resolution | |||
Voltage range | 1-120V | 0.1%FS | 0.1mV | |||
Current range | 1-500mA | 1%FS | 0.1mA | |||
Load | ||||||
Items | Parameters | Accuracy | Resolution | |||
Voltage range | 1-120V | 0.1%FS | 0.1mV | |||
Current range | 1-500mA | 1%FS | 0.1mA | |||
Functions | ||||||
Basic function test | OCV test | |||||
Normal power consumption test | ||||||
Sleep power test | ||||||
Cell over-voltage protection and recover test | ||||||
Cell under-voltage protection and recover test | ||||||
Total voltage over-voltage protection and recover test | ||||||
Total voltage under-pressure protection and recover test | ||||||
Balance voltage and current test | ||||||
Charge and discharge over-current protection and recover test | ||||||
Short-circuit protection and recover test | ||||||
High and low temperature protection and recover test | ||||||
Signal function test | Voltage signal acquisition test | |||||
Temperature signal acquisition test | ||||||
Resistance signal test | ||||||
IO signal input and output | ||||||
Communication function | CANBUS / RS485 / RS232 / I2C / SUMBUS etc. | |||||
Note: For specific models and parameters, please refer to the corresponding technical specifications | ||||||








|