Sign In | Join Free | My infospaceinc.com
infospaceinc.com
Products
Search by Category
Home > Antennas for Communications >

1U 24 Ports Shielded Blank Patch Panel With Folding Cable Manager

Categories Copper Structured Cabling
Model Number: Copper Patch Panel
Bnad: Zion Communication
Brand Name: Zion communication OR OEM
Model: Copper Cabling
MOQ: 1,000 PCS
Packaging Details: 1 PC/Plastic Bag, PCS/Carton
Supply Ability: 30,000 PCS / Month
Payment Terms: T/T,L/C
Delivery Time: Normally 10 workingdays
Certification: ISO, CE, RoHS, UL
Color: Black,Grey
Place of Origin: CHINA
Loading Capacity: 60kg
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

1U 24 Ports Shielded Blank Patch Panel With Folding Cable Manager

Copper Patch Panel / Blank Panel / Engineer Selection

1U 24 Ports Shielded Blank Patch Panel With Folding Cable Manager

The ZCBFPPU-1U24-B2 is a 19-inch 1U 24-port shielded blank patch panel designed for keystone-based structured cabling, combining modular port flexibility with folding rear cable management for cleaner rack deployment and easier cable organization.

Structured Cabling Engineers
System Integrators
Telecom Contractors
IT Procurement Teams
OEM Buyers
Rack Builders
Quick Takeaway
  • 1U 24-port shielded blank patch panel for keystone-based copper systems.
  • Folding cable manager helps improve rear cable discipline in the rack.
  • Best used when projects want modular keystone flexibility instead of fixed loaded ports.
Request Datasheet / Sample
See Decision Rules
Contents
  1. Overview
  2. Key Features
  3. Technical Specifications
  4. Construction / Materials
  5. Applications
  6. Decision Rules / Engineer’s Shortcut
  7. Selection Guide
  8. Packing / Logistics
  9. FAQ
  10. Conclusion
Reserved Image Module

Add front view, folding cable manager view, keystone installation close-up, and rack application image here.

Reserved Video Module

Suitable for keystone snap-in demo, rack installation guide, cable management explanation, or factory overview.

1) Overview

The 1U 24 Ports Shielded Blank Patch Panel With Folding Cable Manager is a modular copper patch panel platform for structured cabling projects that want keystone-based configuration rather than fixed loaded ports. It provides a standard 19-inch 1U rack format, 24 empty module positions, and a folding rear cable-management structure.

For engineering teams, its main value is modular flexibility plus cleaner rack organization. For procurement teams, it enables panel and keystone sourcing to remain separate, which can simplify standardization across projects with different jack requirements.

Field reality

Blank patch panels are often chosen to keep module choice open, but the bigger advantage is that they let procurement standardize the panel platform while engineering teams finalize the exact shielded keystone type later.

2) Key Features

This patch panel is designed for modular copper cabling projects that need a shielded blank panel platform with organized rear cable routing and easy snap-in keystone installation.

FeatureWhat It MeansProject Benefit
1U 24-Port LayoutStandard 19-inch rack format with 24 module positionsSupports common rack planning and standard patch density
Shielded Blank StructureDelivered without keystone jacksKeeps module selection flexible for project-specific needs
Folding Cable ManagerIntegrated folding rear organization structureImproves rear cable routing neatness
Cat5e / Cat6 / Cat6A SuitabilityCan be matched with corresponding keystone typesSupports reuse across broader copper category planning
Snap-In Module StructureEasy to install and unload moduleSimplifies assembly and later replacement
Identification-Friendly DesignLabel and inlaid marks for identification and network managementSupports cleaner administration inside the rack
Blank Dustproof Stoppage SupportUnused module ports can be closed with blank piecesKeeps spare positions neat and visually clean
SPCC MaterialCold rolled steel bodyProvides stable rack-mount construction

3) Technical Specifications

ParameterSpecification
Product Name1U 24 Ports Shielded Blank Patch Panel With Folding Cable Manager
SKUZCBFPPU-1U24-B2
Mounting Standard19-inch
Rack Height1U
Port Count24 ports
Panel TypeEmpty patch panel
Module TypeSuit for fitting with keystone jack
Module DeliveryWithout keystone jack / not including module in the packaging
Cable ManagementWith folding cable management
Compatible CategorySuit for Cat5e / 6 / 6A type
Panel ColorBlack front with silver support bar
MaterialSPCC
Jack CompatibilityCompatible with 24 pcs keystone jacks
Unused Port OptionBlank dustproof stoppage supported
Module Installation MethodSnap-in structure, easy to install and unload module
Key takeaway
Blank modular structure is the main reason to choose this model over a loaded patch panel.
Folding cable manager is a practical advantage for neater rear cable routing.
Cat5e/6/6A suitability gives the panel wider reuse potential across different shielded keystone projects.

4) Construction / Materials

The panel uses an SPCC metal body with a black front face and silver support bar. Its blank-port snap-in structure is designed for modular keystone assembly, while the folding rear section helps keep cable routing more controlled after rack installation.

Construction ElementSpecificationPractical Meaning
Panel bodySPCCSupports stable rack-mount construction
Front appearanceBlack front with silver support barProvides a clear structured look in the rack
Port architecture24 blank module positionsLets the project define final keystone selection separately
Module fitting styleSnap-in structureMakes installation and replacement easier
Cable organizationFolding cable managementImproves rear cable dressing and maintenance order
Unused-port finishBlank dustproof stoppage can be usedKeeps spare positions visually clean and controlled
Practical rule

Choose a blank patch panel when the project wants freedom to define the exact jack type later. Choose a loaded panel when module type is already fixed and assembly speed matters more than modular flexibility.

5) Applications

This patch panel is best suited to structured copper projects that prefer modular keystone architecture, especially where different category levels or staged assembly workflows make a blank panel more practical than a preloaded alternative.

Application ScenarioWhy This Panel FitsWhat to Verify Before Approval
Shielded keystone-based rack buildBlank structure supports flexible jack selectionExact keystone type and quantity
Commercial LAN installationSupports Cat5e / 6 / 6A modular deploymentCategory level and future upgrade plan
Staged procurement projectPanel can be ordered separately from modulesAssembly workflow and module sourcing plan
Rack organization upgradeFolding manager helps improve rear cable orderRear cabinet clearance and cable route
OEM / standardized product platformSupports a repeatable panel platform with project-specific modulesBranding, accessory, and packing expectation

6) Decision Rules / Engineer’s Shortcut

The fastest correct choice starts with three questions: does the project want keystone flexibility, is a shielded panel architecture required, and is integrated cable organization useful in the rack? If yes, this panel is usually a strong fit.

Decision PointChoose This Panel WhenDo Not Choose It WhenAlternative DirectionCost / Risk / Maintainability Impact
Module flexibilityThe project wants to choose keystone jacks separatelyThe module type is fixed and preloaded ports are preferredUse a loaded patch panelCorrect choice avoids paying for unused fixed configuration
Shielding strategyThe project requires a shielded blank panel platformThe system is fully unshielded and does not need shielded panel logicUse an unshielded blank panelCorrect shield matching reduces design inconsistency
Rack organizationRear cable management helps the rack layoutThe cabinet does not benefit from folding management structureUse a simpler blank panel if neededIntegrated management can reduce cable disorder and rework
Category rangeThe project may use Cat5e, Cat6, or Cat6A keystone modulesThe project needs a different module form factorUse a panel matched to the exact module architectureCorrect match improves fit and assembly speed
Unused port appearanceThe project wants clean-looking spare positionsUnused ports are not a visual or operational concernUse blank dustproof stoppage only where neededHelps keep finished racks cleaner and easier to manage
Procurement workflowThe buyer wants panel and modules sourced separatelyA single complete loaded BOM is preferredUse a preloaded assemblyBetter alignment reduces sourcing confusion
Practical rule

Choose this model when the project needs 24 shielded keystone positions in 1U, benefits from integrated folding cable management, and wants the freedom to source modules separately.

7) Selection Guide

A correct selection should evaluate jack-type flexibility, shielding strategy, rear cable-management needs, and logistics planning. That helps avoid ordering a panel structure that does not match the actual rack assembly method.

Selection FactorQuestion to AskRecommendation
Keystone architectureDoes the project want modular keystone choice?Use this panel when jack choice must stay flexible
Category supportWill the project use Cat5e, Cat6, or Cat6A keystones?Confirm module choice before bulk assembly
ShieldingIs a shielded panel platform required for the system?Choose this when shielded architecture is correct
Cable organizationWill rear cable management improve rack maintenance?Use the folding manager where rack neatness matters
Spare positionsWill all 24 ports be populated immediately?Plan blank dustproof stoppage for unused positions
Procurement planningHow many panels and jacks must be packed and shipped separately?Use the carton data for warehouse and freight planning
DimensionValueWhy It Matters
Rack width reference19-inch standard / about 482.6 mm shown in drawingConfirms common rack compatibility
Depth reference82.54 mm shown in side drawingUseful for rear cable-space planning
Height reference44.50 mm shown in drawingSupports rack-space planning
Folding manager spanShown as integrated rear folding structureImportant for cable dressing and cabinet clearance

8) Packing / Logistics

Packing data is important for buyers ordering blank panels in project volume, since panel quantity, keystone quantity, and accessory handling are often planned separately.

Packing ItemSpecificationProcurement Meaning
Inner box quantity1 pc / inner boxSimple single-unit handling and counting
Carton quantity20 pcs / cartonSupports project and freight quantity planning
Inner box size51 × 10 × 5.5 cmUseful for warehouse storage and courier planning
Carton size53 × 42.5 × 30.5 cmHelps freight-volume estimation
Accessories shownM6 screw and nuts, cable tiesImproves installation-readiness visibility

9) FAQ

1. Is this a loaded patch panel or a blank patch panel?

It is a blank patch panel supplied without keystone jacks.

2. What modules is it designed to work with?

It is designed for fitting with keystone jacks and is stated to suit Cat5e, Cat6, and Cat6A types.

3. What is the main advantage of the folding cable manager?

It helps organize rear cable routing and improves rack neatness and maintenance convenience.

4. Can unused module positions be closed?

Yes. The sheet states that not fitted module ports can use blank dustproof stoppage for a cleaner appearance.

5. What should buyers confirm before ordering?

Buyers should confirm the required keystone type, shielding strategy, category level, rack-space plan, and whether the project benefits from the integrated folding cable manager.

6. What packing quantity should procurement plan around?

The product is packed 1 piece per inner box and 20 pieces per carton.

10) Conclusion

The ZCBFPPU-1U24-B2 is a practical 1U 24-port shielded blank patch panel for structured copper deployments that want modular keystone flexibility and cleaner rear cable organization. Its value comes from the blank snap-in architecture, category versatility, and integrated folding cable manager rather than from a fixed loaded-port format.

For best project results, match it to a clearly defined shielded keystone strategy, confirm the exact jack category before assembly, and use the packing data for more accurate logistics planning. When those conditions are clear, it becomes an efficient and flexible patching platform for copper rack systems.

Need help confirming the right blank patch panel configuration?

Send your keystone type, category level, shielding requirement, project quantity, and rack layout plan. ZION can help you confirm the most suitable patch panel platform before purchase.

Request Datasheet / Quote
Back to Top
Suggested parameter checklist
  • Keystone type and category level
  • Shielded system confirmation
  • Need for folding cable manager
  • Blank dustproof stoppage requirement
  • Project quantity and carton planning
  • Rack layout and cable organization preference
Buy 1U 24 Ports Shielded Blank Patch Panel With Folding Cable Manager at wholesale prices
Send your message to this supplier
 
*From:
*To: HANGZHOU ZION COMMUNICATION CO., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0