| Sign In | Join Free | My infospaceinc.com |
|
| Categories | Hipot Tester |
|---|---|
| Model Number: | MY-603 |
| Price: | 4800usd |
| Packaging Details: | carton |
| Place of Origin: | Hubei China |
| Max. Ac VoltageMax. Ac Voltage: | 5kV |
| Supply Ability: | 1000pcs/month |
| Operating Temperature: | 0-40℃ |
| Brand Name: | MINGYANG |
| MOQ: | 1 |
| Payment Terms: | L/C,D/A,D/P,T/T |
| Max. AC Current: | 20mA |
| Delivery Time: | 1 week |
| Display Type: | Digital Only |
| Company Info. |
| Wuhan Mingyang Technology Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
Product Description
| Parameter | Specification |
|---|---|
| Current Channels | Standard 6 phase |
| Voltage Channels | Standard 6 phase |
| AC Current Output Range | 30A/phase or 180A (six parallel) |
| DC Current Output Range | 10ADC/phase |
| AC Voltage Output Range | 120VAC/phase |
| DC Voltage Output Range | 160VDC/phase |
Application Scenarios

FAQ
Question 1: Device powers on but no voltage & current output during
test execution
Customer: The instrument boots up normally, touch screen and keypad
work well. All test parameters are set correctly, yet there is no
output from voltage and current terminals after starting the test.
Manufacturer: Please check items one by one. First, confirm the
external interlock terminal is properly closed. Second, check
whether over‑current, over‑voltage or hardware fault alarm appears
on the screen. Third, verify all output terminals are firmly
connected without loose contact. Fourth, make sure the “test
enable” function is activated. If the fault still exists, stop
operation and contact technical support. Do not disassemble the
device.
Question 2: Large deviation between actual measured value and set
output value
Customer: Readings measured by external multimeter differ greatly
from the output values set on the tester, which affects relay
judgment.
Manufacturer: Poor contact of test cables is the most common cause.
Check cable aging and terminal connection status. Ensure the test
load stays within the rated range of equipment. Run built‑in
self‑calibration program to correct system deviation. Avoid using
ultra‑thin or over‑long test wires for field wiring.
Question 3: Binary input / binary output signal cannot be collected
normally
Customer: Voltage and current output work fine, but the instrument
cannot capture action signal from protective relay, or cannot send
out control signal.
Manufacturer: Check the binary input‑output wiring is connected to
correct terminals. Confirm the auxiliary power supply of external
relay device works normally. Verify binary input mode setting
matches on‑site signal type (active / passive). Restart the test
project after parameter modification.
Question 4: Touch screen malfunction, program crash or test file
loss
Customer: Touch screen is unresponsive occasionally; test software
crashes during complex protection test; saved test files get lost.
Manufacturer: Do not cut off power forcibly during test running.
Close unused test tasks to reduce system load. Regularly back up
test reports to external USB flash drive. If frequent crash occurs,
restore system from factory backup file. Please back‑up data before
restoration.
Question 5: Over‑temperature protection triggers and stops output
under continuous heavy‑load test
Customer: After long‑time continuous heavy‑load test, the tester
pops over‑temperature alarm and cuts off output automatically.
Manufacturer: Keep side ventilation cooling openings unblocked, do
not cover the heat‑dissipation grille. Ambient working temperature
should be 0℃‑40℃. Appropriately reduce continuous heavy‑load
running time. If alarm keeps appearing, check whether the internal
cooling fan works normally.
Question 6: Shipping Method
Customer: If we place an order, how do you typically ship the
goods? Will there be any issues with transporting bulky items such
as reactors?
Manufacturer: We default to using dedicated logistics lines or
brand-specific express shipping services; small-sized main units
and accessories may also be shipped via standard courier services.
Large items, such as reactors and excitation transformers, are
packed using wooden crates or wooden frames for reinforcement to
prevent bumps and moisture exposure during transit; a packing list
is included with each package to facilitate item-by-item counting
for you. Logistics costs are typically determined by both parties
in accordance with the contract terms; after shipment, we will send
you both the tracking number and the carrier's contact phone number
for easy tracking.If your project site is remote or if delivery to
the site is required with a specified logistics company, please
inform us in advance when placing your order; we can then
coordinate and arrange accordingly.
Question 7: Delivery Lead Time
Customer: Our project is under tight deadlines; how long will it
take for the order to be shipped after we place it? Can we request
expedited shipping?
Manufacturer: Standard specifications – stock available; typically
delivered upon receipt of the order. Orders can be shipped within
[X] working days; for non-standard products requiring customized
voltage levels, capacities, or reactor combination configurations,
the production cycle typically ranges from [X] to [Y] days.The
delivery time will be approximately 7-15 working days; the specific
timeline shall be subject to the sales confirmation provided upon
order placement. If your project has a tight schedule, please
inform us of the latest expected delivery date before placing your
order; we will first verify the production schedule and inventory
status, and where possible, will coordinate expedited production
and prioritize shipment. However, it is recommended to allocate
sufficient transit time for logistics to avoid delaying on-site
testing.
Question 8: After-sales Service and Warranty
Customer: What is the warranty period for this equipment? If any
issues arise during on-site use, how will your after-sales service
respond?
Manufacturer: We provide a two-year free warranty on the entire
unit and lifelong technical support services. During the warranty
period, if issues arise due to defects in the equipment itself, we
will provide free repair or replacement of components; when
problems occur on-site, we commit to responding within 24 hours;
most wiring and parameter configuration issues can be resolved
through remote guidance via video or telephone; for cases where an
on-site visit is necessary, we will arrange for our technicians to
arrive at the location to resolve the issue. After the warranty
period expires, we still offer repair services, with spare parts
supplied at cost price for the long term, and software updates
provided free of charge for life. Upon delivery of the equipment,
we also offer free operational training (video operation guides)to
ensure that your testing personnel can operate the equipment
independently and proficiently; should you have any further
questions, please feel free to contact our dedicated after-sales
hotline directly.
Question 9: Shipping methods for each region (Sea freight)
Customer: Our projects are distributed across several states, and
our procurement volumes are substantial; are the shipping methods
consistent across all states? How is the delivery time calculated?
Manufacturer: The specifications are identical; however, it should
be specifically noted that this equipment set is large in size and
heavy in weight—components such as the reactor and excitation
transformer are all classified as heavy components. Therefore,
regardless of which state or region the shipment is destined for,
we will uniformly utilize sea freight transportation. The packaging
employs export-grade wooden crates with reinforced structures,
along with moisture-proof and rust-proof treatments; the design of
these wooden crates is optimized for long-distance sea transport
and multiple lifting and transshipment operations. Upon arrival at
the destination, simply unpack the goods and conduct an inspection
before putting them into use. Regarding delivery time, the sea
freight transit period depends on the port of destination: near-sea
routes are generally faster, whereas ocean routes may take longer;
the exact number of days will be confirmed based on the shipping
schedule specified in the bill of lading. We have a dedicated
freight forwarding agency to handle booking of shipping space,
customs declaration, insurance, and other related procedures; once
the vessel departs, we will send you documents such as the bill of
lading and the packing list, enabling you to arrange for the
receipt of goods at the port of destination and their inland
transshipment in advance
Scene (One)

Scene (Two)

Attachment Directory
| No. | Part Name | Qty |
|---|---|---|
| 1 | 6‑Phase Microcomputer Relay Protection Tester Main Unit | 1 Set |
| 2 | Test Lead Storage Bag | 1 Pc |
| 3 | AC Power Cord | 1 Pc |
| 4 | USB Mouse | 1 Pc |
| 5 | USB Communication Cable | 1 Pc |
| 6 | Spare Fuse (10A,2A) | 4 Pcs |
| 7 | Heavy‑Duty Current Test Cables | 3 Sets |
| 8 | Voltage Test Cables | 2 Sets |
| 9 | Alligator Clip Accessories Kit | 1 Bag |
Attachment Image

|