| Frequency Range (Dummy loads) | 0-2 GHz |
| Frequency Range (Flexible cable connectors) | 0-12.4 GHz |
| Frequency Range (Uncabled receptacles, RA semi-rigid and adapters) | 0-18.0 GHz |
| Frequency Range (Straight semi-rigid cable connectors and field
replaceable connectors) | 0-26.5 GHz |
| VSWR (0-18 GHz) | 1.15 + .02 f (GHz) |
| VSWR (Straight Cabled Connectors - RG-178 cable) | 1.20 + .025f |
| VSWR (Right Angle Cabled Connectors - RG-178 cable) | 1.20 + .03f |
| VSWR (Straight Cabled Connectors - RG-316, LMR-100 cable) | 1.15 + .02f |
| VSWR (Right Angle Cabled Connectors - RG-316, LMR-100 cable) | 1.15 + .03f |
| VSWR (Straight Cabled Connectors - RG-58, LMR-195 cable) | 1.15 + .01f |
| VSWR (Right Angle Cabled Connectors - RG-58, LMR-195 cable) | 1.15 + .02f |
| VSWR (Straight Cabled Connectors - RG-142 cable) | 1.15 + .01f |
| VSWR (Right Angle Cabled Connectors - RG-142 cable) | 1.15 + .02f |
| VSWR (Straight Cabled Connectors - LMR-200, LMR-240 cable) | 1.10 + .03f |
| VSWR (Right Angle Cabled Connectors - LMR-200, LMR-240 cable) | 1.10 + .06f |
| VSWR (.086 semi-rigid) | 1.07 + .008f (Straight) / 1.18 + .015f (Right Angle) |
| VSWR (.141 semi-rigid w/contact) | 1.05 + .008f (Straight) / 1.15 + .015f (Right Angle) |
| VSWR (.141 semi-rigid w/o contact) | 1.035 + .005f (Straight) |
| VSWR (Jack-bulkhead jack adapter and plug-plug adapter) | 1.05 + .01f |
| VSWR (Jack-jack adapter and plug-jack adapter) | 1.05 + .005f |
| Working Voltage (Vrms max - Sea Level - RG-178) | 170 V |
| Working Voltage (Vrms max - 70K Feet - RG-178) | 45 V |
| Working Voltage (Vrms max - Sea Level - RG-316; LMR-100, 195, 200) | 250 V |
| Working Voltage (Vrms max - 70K Feet - RG-316; LMR-100, 195, 200) | 65 V |
| Working Voltage (Vrms max - Sea Level - RG-58, RG-142, LMR-240,
.086 semi-rigid, uncabled receptacles, .141 semi-rigid w/o contact) | 335 V |
| Working Voltage (Vrms max - 70K Feet - RG-58, RG-142, LMR-240, .086
semi-rigid, uncabled receptacles, .141 semi-rigid w/o contact) | 85 V |
| Working Voltage (Vrms max - Sea Level - .141 semi-rigid with
contact and adapters) | 500 V |
| Working Voltage (Vrms max - 70K Feet - .141 semi-rigid with contact
and adapters) | 125 V |
| Dielectric Withstanding Voltage (VRMS min at sea level - RG-178) | 500 V |
| Dielectric Withstanding Voltage (VRMS min at sea level - RG-316;
LMR-100, 195, 200) | 750 V |
| Dielectric Withstanding Voltage (VRMS min at sea level - RG-58,
RG-142, LMR-240, .086 semi-rigid, field replaceable, uncabled
receptacles) | 1000 V |
| Dielectric Withstanding Voltage (VRMS min at sea level - .141
semi-rigid with contact and adapters) | 1500 V |
| Corona Level (Volts min at 70,000 feet - RG-178) | 125 V |
| Corona Level (Volts min at 70,000 feet - RG-316; LMR-100, 195, 200) | 190 V |
| Corona Level (Volts min at 70,000 feet - RG-58, RG-142, LMR-240,
086 semi-rigid, uncabled receptacles, .141 semi-rigid w/o contact) | 250 V |
| Corona Level (Volts min at 70,000 feet - .141 semi-rigid with
contact and adapters) | 375 V |
| Insertion Loss (dB max - Straight flexible cable connectors and
adapters) | 0.06 f (GHz), tested at 6 GHz |
| Insertion Loss (dB max - Right angle flexible cable connectors) | 0.15 f (GHz), tested at 6 GHz |
| Insertion Loss (dB max - Straight semi-rigid cable connectors with
contact) | 0.03 f (GHz), tested at 10 GHz |
| Insertion Loss (dB max - Right angle semi-rigid cable connectors) | 0.05 f (GHz), tested at 10 GHz |
| Insertion Loss (dB max - Straight semi-rigid cable connectors w/o
contact) | 0.03 f (GHz), tested at 16 GHz |
| Insertion Loss (dB max - Straight low loss flexible cable
connectors) | 0.06 f (GHz), tested at 1 GHz |
| Insertion Loss (dB max - Right Angle low loss flexible cable
connectors) | 0.15 f (GHz), tested at 1 GHz |
| Insulation Resistance | 5000 megohms minimum |
| Center Contact Resistance (Initial - Straight cabled connectors and
uncabled receptacles) | 3.0* m |
| Center Contact Resistance (After Environmental - Straight cabled
connectors and uncabled receptacles) | 4.0* m |
| Center Contact Resistance (Initial - Right angle cabled connectors
and adapters) | 4.0 m |
| Center Contact Resistance (After Environmental - Right angle cabled
connectors and adapters) | 6.0 m |
| Center Contact Resistance (Initial - Field replaceable connectors) | 6.0 m |
| Center Contact Resistance (After Environmental - Field replaceable
connectors) | 8.0 m |
| Outer Contact Resistance (Initial - all connectors) | 2.0 m |
| Braid to Body Resistance (Initial - gold plated connectors) | 0.5 m |
| Braid to Body Resistance (Initial - nickel plated connectors) | 5.0 m |
| RF Leakage (dB min - Flexible cable connectors, adapters and .141
semi-rigid connectors w/o contact, tested at 2.5 GHz) | -60 dB |
| RF Leakage (dB min - Field replaceable w/o EMI gasket, tested at
2.5 GHz) | -70 dB |
| RF Leakage (dB min - .086 semi-rigid connectors and .141 semi-rigid
connectors with contact, and field replaceable with EMI Gasket,
tested at 2.5 GHz) | -90 dB |
| RF Leakage (dB min - Two-way adapters, tested at 2.5 GHz) | -90 dB |
| RF High Potential Withstanding Voltage (Vrms min - RG-178, tested
at 4 and 7 MHz) | 335 V |
| RF High Potential Withstanding Voltage (Vrms min - RG-316; LMR-100,
195, 200, tested at 4 and 7 MHz) | 500 V |
| RF High Potential Withstanding Voltage (Vrms min - RG-58, RG-142,
LMR-240, .086 semi-rigid, .141 semi-rigid cable w/o contact,
uncabled receptacles, tested at 4 and 7 MHz) | 670 V |
| RF High Potential Withstanding Voltage (Vrms min - .141 semi-rigid
with contact and adapters, tested at 4 and 7 MHz) | 1000 V |
| Power Rating (Dummy Load) | 0.5 watt @ +25C, derated to 0.25 watt @ +125C |
| Temperature Range | -65C to +165C |
| Cable Retention (Axial Force - RG-178) | 10 lbs |
| Cable Retention (Axial Force - RG-316, LMR-100) | 20 lbs |
| Cable Retention (Axial Force - LMR-195, 200) | 30 lbs |
| Cable Retention (Axial Force - RG-58, LMR-240) | 40 lbs |
| Cable Retention (Axial Force - RG-142) | 45 lbs |
| Cable Retention (Axial Force - .086 semi-rigid) | 30 lbs |
| Cable Retention (Axial Force - .141 semi-rigid) | 60 lbs |
| Cable Retention (Torque - .086 semi-rigid) | 16 in-oz |
| Cable Retention (Torque - .141 semi-rigid) | 55 in-oz |
| Engagement/Disengagement Force | 2 inch-pounds maximum |
| Mating Torque | 7 to 10 inch-pounds |
| Bulkhead Mounting Nut Torque | 15 inch-pounds |
| Coupling Proof Torque | 15 inch-pounds minimum |
| Coupling Nut Retention | 60 pounds minimum |
| Contact Retention (Axial Force) | 6 lbs. minimum |
| Contact Retention (Torque - uncabled receptacles) | 4 inch-ounce minimum |
| Dimensions (A) | .705 inches (17.91 mm) |
| Dimensions (B) | .590 inches (14.99 mm) |
| Environmental (MIL-STD-202 Methods) | Thermal Shock (107, B), Corrosion (101, B), Shock (213, I),
Vibration (204, D), Moisture Resistance (106) |