Sign In | Join Free | My infospaceinc.com
infospaceinc.com
Products
Search by Category
Home > Grain Products >

Low-voltage meter installation and connection training platform

Categories Electrical Training Equipment
Model Number: RM-FZ503
Usage: Education School Sensor Experiment
MOQ: 1 unit
Delivery Time: 30-45 work days
Item name: Electrical Teaching Equipment Model,Teaching instrument
Application: educational training equipment
Certification: ISO9001/ISO45001/ISO14001,
Packaging Details: Wooden packaging
Payment Terms: T/T
Material: China Origin
Type: Electrical and electronic basis examination&training equipment series
Category: Power training equipment,Electrical Engineering Trainer
Brand Name: RUIMU
Training bench: lab equipment for school
Place of Origin: HENAN,CHINA
End user: Professional School,Secondary School
Price: /
Function: educational training electrical equipments/tools for driving learning
Supply Ability: 1unit/30 days
Product name: Electrical Training Equipment Models,Fuse Training System,Digital product maintenance examination educational equipment,Mechanical training equipment,Teaching Equipment
Feature: Interactive driving game,real and functional
Package: Wooden Box
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Low-voltage meter installation and connection training platform

Product Introduction

The RM-Z503 low-voltage meter installation and connection training platform is designed according to the requirements of meter installation and connection workers. Trainees can complete low-voltage meter wiring and perform live-line inspections on the training system. It is suitable for practical training and assessment of related courses in factory power supply and distribution, electrical technology, and other related majors. It can also be used for training personnel in the power industry engaged in metering, meter installation, and meter reading.

  • Operating Environment: Temperature -10℃ to +40℃; Relative Humidity <85% (at 25℃); Altitude <4000m;
  • Power Supply: AC 380V±10%, 50Hz; Power Consumption: ≤3kW;
  • Dimensions: (L*W*H) 1800*800*1750 (mm);
  • Equipment Weight: ≤120kg;

Equipment Functions

  • Training in reading blueprints;
  • Training in using tools and equipment;
  • Training, assessment, and certification in wiring techniques;
  • Wiring practice, training, and competition for high-voltage metering devices;
  • Wiring practice, training, and competition for low-voltage metering devices;
  • Selection, installation, wiring practice, and assessment for current transformers, energy meters, and wires.

Precautions

To ensure personal and equipment safety, operators must carefully read all contents of these safety operation precautions and strictly comply with the requirements of relevant national and power industry regulations and standards.

  • Before training and operation, please review all instructions in this safety operation manual and carefully read the user manual provided with the device.
  • This device is for use by qualified professionals with electrical knowledge and safe operation skills. Personnel without the relevant knowledge are strictly prohibited from performing any operation.
  • Before operating the device, all protective measures required by electrical regulations must be taken. Insulating mats must be laid in front of and behind the control cabinet. During operation, insulated gloves, safety helmets, and work clothes must be worn.
  • Before wiring the meter, ensure the device is de-energized. Install a grounding wire on the device and hang safety warning signs such as "Do Not Close" and "Danger of Electricity." Any live operation is strictly prohibited.
  • The leakage protection of this device can provide personal protection when the circuit or electrical insulation of the device is damaged and a short circuit to ground occurs, but it cannot protect against leakage between phases.
  • Before installing and wiring the meter, ensure the workstation is powered off. It is strictly forbidden to install or connect while the circuit is energized. During installation, it is strictly forbidden to touch two wires simultaneously;
  • Before energizing, report to the training instructor. Energize only after the instructor has inspected and given permission. Disconnect the grounding wire before supplying power. At least two people must be present during energizing the device: one to operate and one to supervise. Energizing without permission is strictly prohibited. Before energizing the device, all safety precautions must be taken, including checking the equipment's power status and ensuring the grounding wire is disconnected;
  • Complying with the training room management regulations and reading the instruction manual and safety warning signs are basic requirements for trainees;
  • Be aware of potential mechanical damage and other personal injuries.
Buy Low-voltage meter installation and connection training platform at wholesale prices
Send your message to this supplier
 
*From:
*To: Henan Ruimu Intelligent Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0