Sign In | Join Free | My infospaceinc.com
infospaceinc.com
Products
Search by Category
Home > Energy Meters >

Three Phase Energy Meter Test Bench-3 Position,HS-5300 Standard Meter 0.05% Acccuracy class,0~100A current

Categories Three Phase Energy Meter Test Bench
Brand Name: SHENGDI TECHNOLOGY
Model Number: HS-6303
Certification: CNAS,SGS.
Place of Origin: ZHEJIANG.CHINA
MOQ: 1 SET
Price: USD$1~100000/SET
Payment Terms: L/C, T/T
Supply Ability: 50 SET/PER MONTHS
Delivery Time: 35~45Days
Packaging Details: WOODEN CASE
Bench accuracy: 01% Class
Standard Meter: 0.05% Class (HS-5300)
Positions: 3 METERS
Current Source: 0~100A,max.120A
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Three Phase Energy Meter Test Bench-3 Position,HS-5300 Standard Meter 0.05% Acccuracy class,0~100A current

    HS-6303 three-phase energy meter testing bench

    SUIT FOR "CT METER"

    HS-6303 three-phase energy meter testing bench adopts SPWM digital power source technology, comprises high-grade standard digital watt-hour meter, multi-path voltage transformer, can implement multi-station high accuracy error testing.

    This testing bench configurates humanized PC processing software, can provide integrated solution of the energy meter automatic check. Meanwhile, it provides the requested DLL of the second development, has improved the self-control and management for the bench by customer.

    This testing bench can be widely used for the energy meter measurement and testing in electric power, water conservancy, traffic transportation and colliery departments, as well as the energy meter testing and production of the energy meter manufacturer.

    This series of testing bench can test all kind of single phase energy meters, single phase multi-function meters, single phase intelligent meters, other meters with special wiring and ANSI standard meter. It is an ideal new generation multi-station energy meter testing device.


    • base on A/D and DSP technology
    • adopt precise digital synthesized technology and sine PWM technology
    • adopt intelligent system control technology, multi-CPU coprocessing technology
    • reliable multi-path pulse testing and precise error testing treatment technology
    • SPWM technology power amplifier, large capacity, high performance, low power consumption, automatic warning protection
    • Error processor of each station distributed networking, heavy current protection, support multi-path pulse signal input
    • Can configurate serial server, implement parallel communication of multi-station, improve work efficiency
    • Modular design, have good universality of parts, easy to disassemble and maintain
    • One-button checking and control management system, automatic finish as per the project
    • Standard cabinet, aluminum alloy frame, nicer and stronger
    • Customized as per specific function

    CLASS0.020.050.1
    Reference standard energy meterHS-5300H 0.02HS-5300 0.05HS-5300 0.1
    Output range

    Voltage:3×30~300V

    Current:3×1mA~120A

    Voltage:3×30~300V

    Current:3×10mA~120A(200A Option)

    Output phase shift0~360°,resolution:0.01°
    Output frequency45~65Hz ,resolution:0.01Hz
    Waveform distortionBoth Voltage and current<0.5%( relative liner load)
    Voltage &current power stability

    <0.02%/120s

    <0.05%/120s

    <0.1%/120s

    Output capacity

    Voltage:300VA(6 stations)

    Current:250VA(120A)

    Voltage:300VA(16 stations)current:900VA(120A)
    if add meters, Max. current: 2000VA,Max. voltage: 1200VA

    Load characteristicsResistive, inductive and capacitive(less than 1uF/station,Max. less than 48 uF)
    Starting up current outputMin.1mA(0.3mA optional),accuracy:5%,starting power:accuracy 5%
    sampling pulse input≤1kHz
    Communication testingRS485/232/ infrared/carrier wave, support DL/T645-1997/2007,IEC1107
    Number of energy meters to be tested6/16(standard),3-60 (optional)
    Environment conditiontemperature:20℃±5℃;humility:<85% R.H.
    Power supply

    AC220 ±10%,50/60Hz,AC120/240V(optional);
    Max. power consumption:3000VA(24 stations)


    IntegrationstationsNumber of rackdimension:L×W×HFissionstationsNumber of rackdimension:L×W×H
    612000×800×16001212000×700×1920
    CUSTOM1612200×700×1920
    1212000×800×19202422000×700×1920
    1612200×800×19203222200×700×1920
    2422000×750×1920cabinet600×800×1920

    DescriptionRange of application
    HS-6303three-phase energy meter testing benchStandard energy meter testing
    HS-6303Bthree-phase multi-function energy meter testing benchMulti-function energy meter testing
    HS-6303Cthree-phase horizontal energy meter calibration benchEnergy meter error calibration
    HS-6303Ethree-phase energy meter test bench with ICTS1P3W energy meter testing
    HS-6303Fthree-phase intelligent energy meter testing benchintelligent energy meter testing
    HS-6303Gthree-phase energy meter (round meter) testing benchStandard energy meter testing
    HS-6303Mthree-phase din-rail energy meter testing benchMulti-function energy meter testing
    HS-6303Hthree-phase high precision energy meter testing benchEnergy meter error calibration

    Function item

    HS-6303

    HS-6303B

    HS-6303C

    HS-6303E

    HS-6303F

    HS-6303G

    HS-6303M

    HS-6303H

    Base testing

    functions

    Base error
    Creep testing
    Starting up testing
    standard deviation
    Constant calibration
    Counting error
    Influencing testing
    Multi-function testingDaily timing error☆
    Period switching
    Demand period error
    Demand display error
    Energy display error
    register checking
    GPS clock synchronization☆
    Communication testing☆
    • :●─standard;〇─optional.

    For Item ☆ need special function parts


    Type

    HS-6303

    HS-6303B

    HS-6303C

    HS-6303E

    HS-6303F

    HS-6303G

    HS-6303M

    HS-6303H

    Standard energy meter
    power source
    error processing system
    multi-path pulse input
    Auto searching mark
    auto short circuit
    ICT
    parallel communication
    carrier communication
    IR communication
    power consumption testing
    DC and even harmonic wave
    standard clock tester
    GPS clock synchronization
    collective turn over & optoelectronic sampling
    • :●─standard;〇─optional

    PRODUCTS DETAILS:


    QUICK CONNECTOR(Active & reactive pulse)


    Signal Source with Big LCD display



    CALIBRATION CERTIFICATION


    As customer's requirement,we can supply 3rd part calibration certification. with CNAS mark.



    Buy Three Phase Energy Meter Test Bench-3 Position,HS-5300 Standard Meter 0.05% Acccuracy class,0~100A current at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Zhejiang Shengdi Technology Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0