FPL Shielded Fire Alarm Cable 18 AWG 2 Core Non-Plenum PVC for Smoke Detectors

Categories Fire Resistant Cable
Place of Origin: China
Brand Name: Zion communication OR OEM
Certification: ISO, CE, RoHS, UL
Model Number: Fire Alarm Cable 18 AWG FPL
MOQ: 20 KM
Packaging Details: 500FT, 1000FT, Wooden Reel, Carton
Delivery Time: 25 working days
Payment Terms: T/T, L/C
Supply Ability: 1000KM / Month
Conductor: Solid Bare Copper
Insulation: PVC Non-Plenmum
Shield: Aluminum / Mylar
Drain Wire: Tinned Copper Wire
Jacket: PVC Non-Plenmum
Color: Red
Package: 500FT, 1000FT, Wooden Reel, Carton
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    FPL Shielded Fire Alarm Cable 18 AWG 2 Core Non-Plenum PVC for Smoke Detectors


    FPL Shielded Fire Alarm Cable 18 AWG 2 Core Non-Plenum PVC for Smoke Detectors


    Quick Details


    • Fire Alarm Cable
    • FPL 18 AWG 2 Core
    • Solid Bare Copper Conductor
    • Unshielded types: 2C / 4C / 6C / 8C
    • Shielded types: 2C / 4C / 6C / 8C
    • Non-Plenum PVC Jacket
    • 500FT, 1000FT, Wooden Reel, Carton
    • Power Limited Fire Alarm Systems
    • MOQ: 20 KM

    Description


    Zion communication ELECTRONICS is the leading manufacturer of fire alarm system cables for the fire protection industry. Our innovative product line includes all power-limited cables for use in the NEC Article 760.
    NATIONAL ELECTRIC CODE (NEC) ARTICLE 760: NEC Article 760 covers the installation of wiring and equipment of fire alarm systems,including all circutis controlled and powered by the fire alarm system.
    These systems are defined in the NEC as " The portion of wiring system between the load side of the overcurrent devices or the power-limited supply and the connected equipment of all circuits powered
    and controlled by the fire alarm system."
    Type FPL- FPL power-limited fire alarm cable is listed by the NEC as being suitable for general purpose
    fire alarm use.This listing excludes installation in riser, ducts, plenums and other spaceused for
    environmental air unless the cable is installed in conduit.All FPL cables are listed as being resistant to
    the spread of fire and must pass both UL test 1424 and the vertical flame testUL 1581.
    KT1417 Fire Alarm Cable 18AWG 2 Core Solid Bare Copper Non-Plenum PVC
    Application
    Indoor for:
    Audio Circuits
    Control Circuits
    Initiating Circuits
    Notification Circuits
    Properties
    Temperature Rating: '-20 to 75℃
    Operating Voltage: 300 Volts max.
    Flame Rating: UL 1685 Vertical Tray
    Insulation & Jacket: PVC
    Unshielded types
    ConductorsNOM.THICKNESS(MM)Nominal0.D.CapacitanceImpedanceDC Resistance
    NumberSolidInsulationJacketInchpf/ftOhmsOhms/M'
    218 AWG0.006"0.015"0.134"20816.5
    418 AWG0.006"0.015"0.170"20816.5
    618 AWG0.006"0.015"0.192"20816.5
    818 AWG0.006"0.015"0.208"20816.5
    Shielded types
    ConductorsNOM.THICKNESS(MM)Nominal0.D.CapacitanceImpedanceDC Resistance
    NumberSolidInsulationJacketInchpf/ftOhmsOhms/M'
    218 AWG0.006"0.015"0.138"42366.5
    418 AWG0.006"0.015"0.160"42366.5
    618 AWG0.006"0.015"0.196"42366.5
    818 AWG0.006"0.015"0.212"42366.5
    Drain Wire22 AWG Solid Tinned-Copper
    Shield0.001" thick Aluminum/Mylar
    Color
    NumberDescription
    2Blk,Red
    4Blk,Red,Ylw,Grn
    6Blk,Red,Ylw,Grn,Brn,Blu
    8Blk,Red,Ylw,Grn,Brn,Blu,Ppl,Pnk
    Order Informations:
    Print

    Zion communication KT1417 ×C20 E×××××××(UL) FPL OR

    CL2 SUN RES(ROHS) ××××FT
    DEVICE/ZONE A B C D E F 1 2 3 4 5 6 7 8 9

    Packing500FT, 1000FT, Wooden Reel, Carton, Pallet

    Competitive Advantage:


    1, From raw materials to final products, we perform intense quality checks to maintain our product quality:

    A, Incoming material inspected by QC.

    B, Manufacturing Process Control

    C: Workers trained daily/weekly/monthly

    D: Work instructions manual at each work station

    E: 5S system implemented

    F: Machine maintenance procedure

    G: Quality Control and Final Inspection

    The QC staff will check the material, process product

    and final product according to the specification or test procedure.


    2, Our R&D efforts center on reinforcing and developing element technologies

    needed to support the future growth and success for customers and Zion communication.

    3, We know customers have urgent needs.

    We are skilled at effective communication to interact with customers.

    In order to provide prompt service, we can answer for you 7*24 hours.

    4, We can Quickly and professionally answer for the inquire

    5, More than 1000 kinds of cable, connectors and assembles can be produce and organized from us

    6, Intime delivery


    Buy FPL Shielded Fire Alarm Cable 18 AWG 2 Core Non-Plenum PVC for Smoke Detectors at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: HANGZHOU ZION COMMUNICATION CO., LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0