Sign In | Join Free | My infospaceinc.com
infospaceinc.com
Products
Search by Category
Home > Seals >

969-95-24960 Shield Cap For Komatsu 1.4mm Nozzle , Komatsu Plasma Cutting Machine Parts

Categories Komatsu Plasma Machine Consumables
Brand Name: Plasma Consumables
Model Number: 969-95-24960
Certification: ROHS/ SGS
Place of Origin: China
MOQ: 5pcs
Price: negotiation
Payment Terms: T/T or western Union
Supply Ability: 10,000pcs per month
Delivery Time: Prompt goods
Packaging Details: Manufacturer packing
Product Name: Plasma Consumables
Application: Plasma Cutting Machine
Standard: Manufacturer production standard
type: 969-95-24960
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    969-95-24960 Shield Cap For Komatsu 1.4mm Nozzle , Komatsu Plasma Cutting Machine Parts

    969-95-24960 Shield Cap For Komatsu 1.4mm Nozzle, Komatsu Plasma Cutting Machine Parts


    Shanghai ZhouBo Welding & Cutting Technology is specialized in Welding & Cutting consumables with Good Quality, Competitive Price, On-Time Delivery and Excellent Services and we are looking for long-term friendly cooperation with you.

    Komatsu plasma Cutting machine 30KW, 60KW accessories, plasma consumables. Komatsu plasma 3082, 3084, 3086 plasma cutting accessories, Komatsu plasma torch parts. Komatsu plasma cutter nozzle 969-95-24130 1.3mm, plasma cutting nozzle 969-95-24180 1.1mm, nozzle 969-95-24190 0.8mm, nozzle 969-95-24770 0.6mm, nozzle 969-95-24930 1.4mm, nozzle 969-95-24920 1.6mm, Koike electrode 969-95-24310, electrode 969-95-24910, Shield 969-95-24340, Shield 969-95-24750, Shield 969-95-24810, Shield 969-95-24950, Shield 969-95-24960


    1. HEC Brand


    We make metal cutting system and plasma cutter as well as torch and consumables. We make plasma cutting machine and fiber laser cutting machine with high quality and reliablity.


    2. Cut Performance


    HEC plasma consumables use high quality material and standard process to make sure the highest quality. Our consumables cutting performance is as the same as orginial OEM manufactory.


    3. Good Price


    HEC plasma consumables are good quality with low price make customers best requirement and saving money.


    4. Big Catagory


    HEC sell all kinds of plasma consumables include , EASB, Kjellberg, Koike and also supply some torch.


    MachineHEC NO.Ref NO.Description
    30KWL41470969-95-24470Outer Cap
    L21750969-95-24750Shield Cap (<t6mm)
    L21810969-95-24810Shield Cap (>t6mm)
    L31141969-95-24141Ring
    L11130969-95-24130Nozzle 1.3mm
    L11190969-95-24180Nozzle 1.1mm
    L11180969-95-24190Nozzle 0.8mm
    L11770969-95-24770Nozzle 0.6mm
    L71320969-95-24320Guide A (Nozzle 1,3,1,1mm)
    L71780969-95-24780Guide B (Nozzle 0.8,0.6mm)
    L01310969-95-24310Electrode
    L91410969-95-24410Shim for Outer cap
    L91162969-94-24162Center pipe
    L91163969-94-24163Center pipe
    L81311969-94-24311Torch Body Kit
    L81312969-94-24312Torch Body Kit
    L90990969-95-10990Cooling water
    L01910969-95-24910Electrode
    L11920969-95-24920Nozzle 1.6
    L11930969-95-24930Nozzle 1.4
    L21950969-95-24950Shield Cap 1.6
    L21960969-95-24960Shield Cap 1.4
       



    Technical Support:

    Common problems in the application of plasma cutting machine


    Plasma cutting electrical arc stability directly affect the cutting quality, plasma arc unstable phenomenon, lead to incision is uneven, product of melanoma defects, may also lead to the decrease of the control system of the related components life, nozzle and electrode frequent replacement. In view of this phenomenon, analyze and propose solutions.


    1 low pressure


    "Plasma cutting machine work, such as work pressure far below specifications required pressure, which means of the arc plasma jet velocity weakening, input the air flow is less than the specified value, this form of high energy and high speed of plasma arc, causing the incision quality is poor, cut through, incision tumor of the product phenomenon. Insufficient pressure of the reasons are: air compressor input, cutting machine, air regulator low voltage, electromagnetic valve oil, gas path is obstructed etc..


    "The solution is, before use to observe the air compressor output pressure display, if not meet the requirements, adjust the pressure or the maintenance of air compressor. If the input pressure has reached the requirements, should be properly adjusted check air filter relief pressure valve, gauge display can meet the cutting requirements. Otherwise deal with air filter relief pressure valve for routine maintenance, ensure that the air dry, no oil. If the input can cause poor air quality, oil solenoid valve, the valve opening, the valve port is not fully open. In addition, torch nozzle pressure is too low, also need to replace the solenoid valve; gas road section variable is caused by pressure is too low, according to the specifications for tracheal replacement.


    2 high pressure


    "If the input air pressure far exceed 0.45MPa, after the formation of the plasma arc, the large flow of air will blow concentrated arc column, the energy of arc column dispersion, decreased the plasma arc cutting intensity. Cause the pressure is too high, the reasons are: improper input air conditioning, air filter regulator is too high or air filter valve failure.


    The solution is to check whether the pressure of the air compressor is adjusted properly, air compressor and air filter pressure relief valve is dysfunctional. After startup, such as rotating air filter relief pressure valve adjusting switch, gauge unchanged, indicating that the air filter relief pressure valve failure, need to be replaced.


    3 cutting torch nozzle and electrode


    "Since the nozzle installation is improper, such as threads are not tightened, equipment of each block bit improper adjustment, need water cooling of the torch at work, not in accordance with the requirements of pass into the flow of cooling water and frequent arcs, will cause premature failure of the nozzle.


    "The solution is, in accordance with the requirement of technology of the workpiece cutting and the correct adjustment of equipment gear, check the torch nozzle is installed firmly is, through the cooling water nozzle should be made in advance in cooling water circulation up. When cutting, cutting torch and workpiece thickness adjustment according to workpiece distance.


    4 input AC voltage is too low


    Plasma cutting machine using the site has a large power use facilities, cutting machine internal main circuit components, etc., will make the input AC voltage is too low.


    The solution is to check whether there is sufficient capacity of the plasma cutting machine access to the power grid, the power line specifications are in line with the requirements. Plasma cutting machine installation location, should be far away from large electrical equipment and often have electrical interference place. The use of the process, to regularly clean the dirt and dust cutting machine components, check the wiring is aging etc..


    5 poor contact with the ground


    "The ground is essential preparation before cutting work a. Without the use of special grounding tool, workpiece surface insulation and long-term aging serious ground, will cause poor contact with the ground.


    Should use special grounding tool, and check whether the insulation effect of the ground contact with the workpiece surface, avoid the aging ground.


    6 spark generator can't be broken arc


    Plasma cutting machine, first of all to ignite the plasma arc, by the high frequency oscillator excited gas between the electrode and the inner wall of the nozzle, resulting in high-frequency discharge, the gas ionization and the formation of local small arc, the small arc by compressed air, ejected from the nozzle to ignite plasma arc. This is main task spark generator. Under normal circumstances, the spark generator working time is 0.5 ~ 1s, the reason does not automatically break arc is generally offset control circuit board components, discharge electrode gap of the spark generator is not right.


    Should always check the spark generator discharge electrode, make the surface smooth, timely adjustment of the discharge electrode gap spark generator (0.8 ~ 1.2mm), it is necessary to change control board.


    7 other


    "In addition to the above reasons, the cutting speed is too slow, cutting the verticality of the torch and workpiece, and the operator of the plasma cutting machine familiarity, the operation level and influence the stability of the plasma arc, the user should notice in these aspects.

    Buy 969-95-24960 Shield Cap For Komatsu 1.4mm Nozzle , Komatsu Plasma Cutting Machine Parts at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Shanghai Zhoubo welding & cutting technology CO.,LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0