Temperature chamber Door opening alarm Temperature Humidity Chamber

Categories Temperature Humidity Chamber
Brand Name: Haida
Model Number: HD-E702
Certification: CE,,ISO
Place of Origin: China
MOQ: 1
Price: Negotiation
Payment Terms: L/C, T/T, D/A, D/P, Western Union, MoneyGram
Supply Ability: 75 Piece / Pieces Per Month
Delivery Time: 15 Days After Order
Packaging Details: Strong Wooden Case
Usage: Constant Temperature and Humidity Testing Machine
Temp. range: -70°C~150°C
Humid. range: 10~ 98 percent R.H.
Resolution: 0.01°C, 0.1 percent, P.I.D control
Interior dimension(W×D×H): 100×100×80cm
Interior material: Stainless steel plate(SUS304)
Display: LCD
Weight: Approx. 600 kg
Power: AC220V±10 percent 50/60Hz
Use: temperature test equipment
Company Info.
Hai Da Labtester
Verified Supplier
View Contact Details
Product List
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Temperature chamber Door opening alarm Temperature Humidity Chamber

    Temperature chamber Door opening alarm Temperature Humidity Chamber


    Temperature and humidity chamber.pdf


    Temperature chamber Door opening alarm Temperature Humidity Chamber can simulate different environment condition. It's appropriate for testing material performance, such as resist heat, resist dry,resist humidity and resist cold. That can define performance of material.


    1. Specifications of Temperature and Humidity Stability Test Machine


    Range – 70 to 150°C

    Temp/Humidity

    HD-E702-100-7

    HD-E702-150-7

    HD-E702-225-7


    HD-E702-408-7

    HD-E702-800-7

    HD-E702-1000-7

    Temp-only

    HD-E702-100T-7

    HD-E702-150T-7

    HD-E702-225T-7


    HD-E702-408T-7

    HD-E702-800T-7

    HD-E702-1000T-7

    Temperature Range:

    -70°C ~150°C

    Cooling Capacity

    ~ 2.5 kW at -50°C

    ~ 3 kW at -50°C

    ~ 5 kW at -50°C

    ~ 6.5 kW at-50°C

    ~ 8.5 kW at -50°C

    ~ 9 kW at - -50°C

    Heating System

    ~ 5 kW

    ~ 5 kW

    ~ 5.5 kW

    ~6.5 kW

    ~ 8.5 kW

    ~ 9 kW

    Temperature Fluctuation:

    ±0.5°C

    Temperature Gradient:

    ±0.5°C~±0.2°C

    Heating Rate†:

    ≥3℃ / min average ( Advance model 5 – 15 ℃ / min)

    Cooling Rate†:

    ≥1℃ / min average (Advance model 5 - 15℃ / min)

    Humidity Range:

    10%~95%RH (Ref to Normal Humidity Range Diagramed)

    Humidity Fluctuation:

    ±1.5%RH~±2.0%RH

    Humidity Gradient:

    ±3%RH

    Dimensions

    Workspace dimensions
    (WxDxH)mm:

    500x400x500

    HD-E702-100

    600x500x500

    HD-E702-150

    750x500x600

    HD-E702-225


    850x650x800

    HD-E702-800

    1000x1000x800

    HD-E702-800

    1000x1000x1000

    HD-E702-1000

    Exterior dimensions
    (WxDxH)mm:

    1400x850x1050

    1500x950x1050

    1650x950x1150


    1750x1050x1350

    1900x1450x1350

    1900x1450x1550

    Site Requirements

    Electrical Supply:

    208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)

    Humidity Water

    Distilled water

    Condensate Drain:

    1/2" hose connection (gravity drain)


    Range – 40 to 150°C


    Temp/Humidity

    HD-E702-100-4

    HD-E702-150-4

    HD-E702-225-4


    HD-E702-408-4

    HD-E702-800-4

    HD-E702-1000-4

    Temp-only

    HD-E702-100T-4

    HD-E702-150T-4

    HD-E702-225T-4


    HD-E702-408T-4

    HD-E702-800T-4

    HD-E702-1000T-4

    Temperature Range:

    -40°C ~150°C

    Cooling Capacity

    ~ 2 kW at -20°C

    ~ 2.5 kW at -20°C

    ~ 4.5 kW at -20°C

    ~ 5.5 kW at-20°C

    ~ 8 kW at -20°C

    ~ 8.5 kW at - -20°C

    Heating System

    ~ 5 kW

    ~ 5 kW

    ~ 5.5 kW

    ~6.5 kW

    ~ 8.5 kW

    ~ 9 kW

    Temperature Fluctuation:

    ±0.5°C

    Temperature Gradient:

    ±0.5°C~±0.2°C

    Heating Rate†:

    ≥3℃ / min average ( Advance model 5 – 15 ℃ / min)

    Cooling Rate†:

    ≥1℃ / min average (Advance model 5 - 15℃ / min)

    Humidity Range:

    10%~95%RH (Ref to Normal Humidity Range Diagramed)

    Humidity Fluctuation:

    ±1.5%RH~±2.0%RH

    Humidity Gradient:

    ±3%RH

    Dimensions

    Workspace dimensions
    (WxDxH)mm:

    500x400x500

    HD-E702-100

    600x500x500

    HD-E702-150

    750x500x600

    HD-E702-225


    850x650x800

    HD-E702-800

    1000x1000x800

    HD-E702-800

    1000x1000x1000

    HD-E702-1000

    Exterior dimensions
    (WxDxH)mm:

    1400x850x1050

    1500x950x1050

    1650x950x1150


    1750x1050x1350

    1900x1450x1350

    1900x1450x1550

    Site Requirements

    Electrical Supply:

    208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)

    Humidity Water

    Distilled Water

    Condensate Drain:

    1/2" hose connection (gravity drain)


    2. Performance


    Get a performance evaluation to help provide the suitable chambers to you.


    For better assurance of performance for your temperature and humidity cycling application, Haida can provide a guaranteed performance calculation based on your submitted requirements.


    Please use these questions as below as a guide to define your test plan. You can then give this information to our lab consultant or email to us, for review by our lab consultant. A recommended model with appropriate refrigeration size will provide to you.


    Questions for Performance Evolution Request


    temperature test equipment


    System & Performance Options

    • Low and Ultra-Low Humidity Extends the humidity control range. (Normal Humidity Range Diagramed)
    • Water-cooling system.
    • Dry Air Purge keeps moisture in the chamber extremely low by purging with -40 °C. Compressed air supply required
    • Additional shelves, 50 Kg loading
    • Cable ports with flexible silicone plug, 50 , 100, 150mm or customer specific diameters

    temperature test equipment

    (Normal Humidity Range Diagramed)


    3. Features of Temperature and Humidity Stability Test Machine


    Vice lock type door and foam silicone packing to ensure a perfect seal Cartridge type tank for easy adding and changing of water


    Tempered glass window with lamps provides a clear view of samples in the chamber, beneficial during testing Easy cleaning of condenser air-filter to prevent deterioration of refrigeration system


    Leakage breaker for power supply Over current protection Overheat / overcool protection Switch-off after alarm for over heating Water empty / Door open alarm Vice lock door type locking mechanism


    Standard Features

    • Stainless# 304 steel for interior
    • Paint steel for exterior
    • Foam-insulated door for rigidity and long life
    • Plastic water tank easy for maintenance
    • Observation Window with frost free function
    • High performance refrigeration system
    • Easy user interface for TEMI-880 PLC controller
    • One 100mm cable port/ Customer specified
    • One shelve, 10 Kg loading & 4 casters included
    • Van Type Sirocco,L134,Fan
    • PID controlled-Stainless Steel Humidifier
    • DuPont R-404A [No Fluorine] Refrigerant / 23 for below -40 °C
    • USB port for data output
    • Anti-explosive interior lamps
    • Data logging chart recorders, paperless recorders stored data in the PLC.
    Buy Temperature chamber Door opening alarm Temperature Humidity Chamber at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Hai Da Labtester
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0