Sign In | Join Free | My infospaceinc.com
infospaceinc.com
Products
Search by Category
Home >

RS485 RS232 Environment Monitoring System

Categories Environment Monitoring System
Brand Name: ESTEL
Model Number: SM2400
Certification: ISO9001, CE, 3C, FCC, TLC
Place of Origin: Shenzhen, China (Mainland)
MOQ: 1
Price: negotiation
Payment Terms: L/C, D/A, D/P, T/T, Western Union
Supply Ability: 30,000 sets per month
Delivery Time: 7-10 working days
Packaging Details: carton/wooden case
Monitored Sensors: door sensor, smoke sensor, water sensor, temperature and humidity sensor, etc.
Application: Outdoor Telecom Cabinet
Analog Input: eleven ways
Digital Input: eight ways
Digital Output: ten ways
Power Consumption: <10W
Operating Voltage: 48VDC
MTBF: >50000 hours
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    RS485 RS232 Environment Monitoring System


    RS485 RS232 Environment Monitoring System With Door Sensor / Smoke Sensor


    Quick Details:


    Place of Origin: Shenzhen, China (Mainland)

    Communication Interface:

    RS232/RS485 or TCP/IP (Ethernet) Including communication protocol and software

    Brand Name: ESTELAnalog Input: eleven ways
    Model Number: SM2400Digital Input: eight ways
    Product Name: Environment Monitoring SystemDigital Output: ten ways
    Certification: ISO9001, CE, 3C, FCC, TLCPower Consumption: <10W
    Alarm Sensors: door sensor, smoke sensor, water sensor, temperature and humidity sensor, etc.Operating Voltage: 48VDC
    Application: Outdoor Telecom Cabinet

    MBTF: >50000 hours


    Payment & Shipping Terms:


    Minimum Order Quantity:1 set
    Price:negotiation
    Payment Terms:L/C, D/A, D/P, T/T, Western Union
    Supply Ability:30,000 sets per month
    Delivery Time:7-10 working days
    Packaging Details:carton/wooden case

    1. Specifications


    Technical Parameters


    • Analog Input: eleven way; four ways specially for temperature and humidity measurement, the other seven ways for universal AI. AI1~AI6: 0 ~ 5V, 1 ~ 5V input; AI7: internally connected with DC48V;
    • Digital Input: eight ways; one way specially for utility power detection (220VAC input), the other seven ways for universal DI input, function redefinable;
    • Digital Output: ten ways; universal DO output, function redefinable;
    • Temperature Measurement Range: -50°C ~ 85°C, accuracy 0.1 °C; humidity measurement accuracy ±4%;
    • Three Control Modes for DO Output: manual output, SU remote control, automatic control;
    • Daily Record Storage And Query Function: recent 180 days’ daily records for query, including every day’s highest, lowest, average temperature, TEC air conditioner start times, operating time length, daily alarm event etc;
    • RS232/RS485 or TCP/IP communication interface;
    • Working Voltage Range: 36VDC ~ 72VDC;
    • Working Temperature Range: -20°C ~ 80°C;
    • Power Consumption: <10W
    • MBTF: >50000 hours

    2. Application


    The SM2400 Environment Monitoring Unit is a device used for monitoring working environment conditions inside outdoor telecom cabinet or outdoor power cabinet etc.


    3. Description

    3.1 Summary


    The SM2400 Environment Monitoring Unit uses dual core processing. The power supply uses DC/DC module. The measuring channel, power supply, and communication interfaces are electrically isolated, so the monitoring unit has high reliability. The MCU control design has functions of self-management and self-correction. SM2400 monitoring unit support RS485/RS232/Ethernet communication method. With the communication interfaces, it can realize many kinds of communication modes, such as point to point communication, point to multipoint communication, wireless remote communication, which can meet the need of various system networks.


    3.2 Control Board


    The following figure shows the control board of the environment monitoring unit. It includes one LCD screen, four operating buttons, three working indicator lights, multiple wiring ports and one power supply switch.



    (1) Power Switch: turn on or turn off power.


    (2) LCD Display Screen:


    It shows different contents under the following three status.


    Operating Mode: the first line shows indoor temperature and humidity; the second line shows the real-time clock, among which the first letter “A” stand for automatic output, ”M” stand for manual output. One can directly revise DOx register to amend the output status.


    Menu Mode: can select eleven menu items in sequence.


    Parameter Mode: shows parameter name and parameter value. For detail, please check the “3 Operation and Parameters”.


    (3) Four buttons:


    PgDn:


    At operating status: press once and release the button, enter menu operation interface;

    At menu selection interface: press once to enter the selected parameter group;

    At parameter status: revise, confirm and parameter page down button; a long press on the button to exit parameters and to menu interface;

    At query status: select the former day’s daily record, a long press on the button to exit query and to menu interface;


    ▲:Increasing parameter revision. Page down button for event query.


    ▼:Decreasing parameter revision. Page up button for event query.


    PgUp:


    At parameter status: page up button; the function is oppose to PgDn operation;

    At menu selection interface: press once to exit parameter status and come to operating status;

    At query status: select the latter day’s daily record; at current daily record, press the button to exit query.


    (4) Three Status Lamps:


    PWR : power indicator; when it is bright, it shows being connected with DC48V;

    Work : when the system is working, it flashes at 1HZ frequency;

    Alarm : system alarm occur.


    3.3 Wiring Ports


    The ports from left to right is shown as follows. The far left is JD1.

    JD1: DC48V power supply input; 1-0V; 2--48V;

    JD2: temperature and humidity sensor 2 input port;

    4-5V; 3-Temp2; 2-Hum2; 1-0V;

    JD3: temperature and humidity sensor 1 input port;

    4-5V; 3-Temp1; 2-Hum1; 1-0V;

    JD4: RS485 communication port and universal digital output DO10;

    1-A+, 2-B, 3-GND; 4-normal open, 5-public, 6-normal close;

    JD5: universal digital output DO9, DO8, DO7:

    DO9-1, 2; DO8-3, 4; DO7-5, 6;

    JD6: universal digital output DO6, DO5, DO4:

    DO6-1, 2; DO5-3, 4; DO4-5, 6;

    JD7: universal digital output DO3, DO2, DO1:

    DO3-1, 2; DO2-3, 4; DO1-5, 6;

    Note: (1) All the digital output DO can be redefined;

    (2) Factory default:

    DO1-door sensor; DO2-smoke sensor;

    DO3-water sensor; DO4-utility power;

    DO5-temperature 1 (battery compartment) alarm;

    DO6-temperature 2 (equipment compartment) alarm;

    DO7-system general alarm.

    (3) Only DO10 can withstand 7A current, others are 1A current.


    JD8: universal analog input port AI6:

    1-12V, 2--12V, 3-AI6, 4-GND(AG);

    JD9: universal analog input port AI5:

    1-12V, 2--12V, 3-AI5, 4-GND(AG);

    JD10: universal analog input port AI4:

    1-12V, 2--12V, 3-AI4, 4-GND(AG);

    JD11: universal analog input port AI3:

    1-12V, 2--12V, 3-AI3, 4-GND(AG);

    JD12: universal analog input port AI2:

    1-12V, 2--12V, 3-AI1, 4-GND(AG);

    JD13: universal analog input port AI1:

    1-12V, 2--12V, 3-AI2, 4-GND(AG);

    Note:(4) AI1~AI6 can be connected with standard Hall current sensor, detecting 6 way current.


    JD14: universal digital input port DI4, DI3:

    DI4-1(GND-AG), 2(DI4), 3(12V-AV);

    DI3-4(GND-AG), 5(DI3), 6(12V-AV);

    JD15: universal digital input port DI2, DI1:

    DI2-1(GND-AG), 2(DI2), 3(12V-AV);

    DI1-4(GND-AG), 5(DI1), 6(12V-AV);

    JD16: universal digital input port DI5(Smoke):

    1-GND(AG), 2-S1, 3-S2, 4-12V(AV)

    JD17: universal digital input port DI6(Water):

    1-GND(AG), 2-W1, 3-W2, 4-12V (AV)

    JD18: DI7 digital input, dry contact input, standard configuration is door sensor input;

    JD19: utility power detection input, detecting AC220V, DI8;

    Note: (1) Except DI8, all other universal DI can be redefined;

    (2) Factory default: DI7 - door sensor; DI5 - smoke sensor; DI6 - water sensor;

    3.4 Digital Input


    The digital input circuits are all passive inputs, as the below diagram, so the equipment output should be active output (12V).



    Digital Input Circuit Principle Diagram


    4. Communication Function Instruction


    The controller provides serial asynchronous half duplex RS485 or RS232 communication port, and uses MODBUS-RTU protocol. All types of data information can be transmitted through the communication line. Multiple network controllers can be simultaneously connected on one line. Communication address no. for each network controller can be set. The communication connection should use shielded twisted pair with copper mesh, and the wire diameter should not be smaller than 0.5mm2. For wiring, the communication line should be far away from strong electricity cables or other strong electric field environment. It is recommended to use T type network connection mode, and not to use star connection or other connection modes.


    MODBUS_RTU communication protocol: MODBUS protocol adopts the communication connection mode of master slave response on one communication line. Firstly, signal of the master computer addresses one terminal equipment (slave equipment) with unique address; Then the response signal sent by the terminal equipment is transmitted to the master computer in opposite direction. In other words, on only one communication line, signal transmits all communication data flow along with two opposite directions ( half duplex working mode). MODBUS protocol only allows communication between master computer (PC, PLC) and terminal equipment, but don’t allow data exchange between independent terminal equipments, so that each terminal equipment will not occupy communication line during their initialization, and will only occupy the communication line when responsing to query signal sent to it.


    Master computer query: query information frame includes equipment address code, function code, data information code, check code. The address code shows the selected slave equipment. The function code shows the function the selected slave equipment will execute. For example, function code 03 or 04 requires to read register from equipment and return their content. The data information code includes other additional information about the function the selected slave equipment will execute. For example, in the read command, the additional information includes which register it will firstly read from and the quantity of the registers to be read. The check code are used for checking the correctness of one frame information, providing slave equipments a method of checking if the information content is correct. It uses CRC16 calibration rule.


    Slave equipment response: if slave equipments generate one normal response, the response information will include slave equipment address code, function code, data information code and CRC16 check code. The data information code includes data collected by the slave equipment, such as register value or status. If error occurs, the slave equipment will not response or return two FF.


    Transmission mode refers to a series of independent data structure in one data frame and rules for data transmission.


    5. Sensors and LED Lamp Specs


    5.1. Door Sensor


    (1) Technical Parameters:

    Contact power: ≤10W

    Voltage: ≤28VDC

    Current: ≤0.5A

    Contact impedance: ≤300mΩ

    Action distance: 35mm

    Fixing mode: embedded

    Safety standard(UL):94-HB


    Function:


    When forcible entry (forcible opening the cabinet door) happens, the door sensor will send the door alarm signal, and transmit the alarm signal to the monitoring center in switching mode.


    Size:



    5.2. Smoke Sensor


    Technical Parameters:


    Voltage: 5-24 VDC

    Power: ≤1W

    Working temperature: -20°C ~ 70°C

    Working humidity: 0% ~ 95%

    Communication mode: contact output


    Function:


    When burning or smoke happens inside the cabinet, the sensor will send out alarm signal, and transmit the alarm signal to the monitoring center in switching mode.



    Size:



    5.3. Water Sensor


    (1) Technical Parameters:

    Voltage: 5-15 VDC

    Power: ≤0.5W

    Alarming water level: 5mm

    Working temperature: -20°C ~ 70°C

    Working humidity: 0% ~ 95%

    Communication mode: contact output


    (2) Function:

    When water level inside the cabinet reach the alarming level, the sensor will send out alarm signal, and transmit the alarm signal to the monitoring center in switching mode.



    • Size:


    5.4. Temperature and Humidity Sensor


    (1) Technical Parameters:

    Voltage: +5VDC

    Power: <0.5W

    Temperature error: ±0.2°C

    Temperature resolution: 0.0625°C

    Working temperature: -50°C ~ 120°C

    Working humidity: 0% ~ 95%

    Communication mode: monobus


    (2) Function:

    When temperature inside the cabinet exceed the set range, the sensor will send out high temperature or low temperature alarm signal, and transmit the alarm signal to the monitoring center in switching mode.


    • Size:


    5.5 LED Lamp


    (1) The working voltage of the lamp is -48VDC.

    (2) LED lamp can turn on or turn off intelligently. When the cabinet door is open, the LED will turn on automatically. When the cabinet door is closed, the LED will turn off automatically.


    (3) LED Lamp Size:


    LED Lamp Dimension Diagram


    (4) LED Lamp Cover Size:



    6. Packing and Shipping




    Our Delivery Agent


    The goods can be shipped by sea, by air, by courier, by land, by train, etc.

    Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.



    7. Our Contact Information


    Mobile Phone: 0086-13752765943

    Telephone: 0086-0755 66600941

    Email: info@estel.com.cn

    lxf.estel@hotmail.com
    Skype: fiona.liang10


    8. Our Partner

    Buy RS485 RS232 Environment Monitoring System at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Tianjin Estel Electronic Science and Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0