Sign In | Join Free | My infospaceinc.com
infospaceinc.com
Products
Search by Category
Home > Active Components >

30 - 1200KVA Online Three Phase Ups Systems , Parallel Redundant Ups System High Efficiency

Categories Modular UPS System
Brand Name: CONSNANT
Model Number: CNM330 -300K
Certification: CE, ISO9001, ISO14001
Place of Origin: Shenzhen, China
MOQ: 1 Unit
Price: Negotiable
Payment Terms: T/T, L/C, Western Union
Supply Ability: 500 pieces per month
Delivery Time: 20days after receiving 30% deposit
Packaging Details: Export Standard Package
Battery Voltage: ±240VDC(Default),12V Battery 30~40pcs can be choose
Bypass Input Voltage: 380/400/415VAC 3-phase 4-wire
nverter Output Voltage: 380/400/415VAC 3-phase 4-wire
Operation Temperature: 0-40ºC (Storage Temperature-25ºC~70ºC ,without battery)
Humidity: 0-95% (no-condensing)
Noise(dB): 55-62dB,Adjusted with load
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    30 - 1200KVA Online Three Phase Ups Systems , Parallel Redundant Ups System High Efficiency

    THDi < 3% UPS Uninterrupted Power Supply Modular Online UPS

    30 - 1200KVA​



    CNM330 series is a modular online UPS for sensitive equipment. The single cabinet power rating covers from 10KVA to 300KVA which delivers the best of combination of reliability, hot-swappable and flexibility. With the latest IGBT three-level technology and DSP control, CNM330 achieves a high input power factor, low THDi Modular design with N+X redundancy and online hot swapping ,easy to expand the capacity Full DSP control of high stability, reliability and safety Integrated IGBT module with improved performance and reduced size



    Application:


    Application IDC(Internet Data Center)
    Computing center
    ISP (Internet Service Provider )
    Telecom , Finance, bank and securities , Tax
    Hospital system , industrial automation
    Precision equipment, etc.


    Features:


    ■ Superior energy saving :
    ■ Easy-to-install:
    ■ Easy-to-maintain:
    ■ Easy-to-modify:
    ■ Extra large LCD that can display 12 language (Chinese ,English ,Russian, French ,Spanish and so on)
    ■ Provide large LCD touch screen (optional)
    ■ Each UPS modules provide 4.5KW charge capacity. equivalent to 10 to 12A
    ■ Advanced DSP full digital control technologies realize higher system stability, online capacity expansion and maintenance
    ■ Advanced distributed active parallel technology realizes parallel operation of 4 UPS units and online capacity expansion without centralized bypass cabinet
    ■ Adaptive to severe power grid environment due to extra wide input voltage and frequency ranges
    ■ Intelligent battery management maintains battery automatically to prolong the battery life
    ■ The machine system for modular structure, consists of 1 to 10 module's biggest single module to 30kw
    ■ UPS power module supporting hot swappable, capacity upgrade extremely simple.
    ■ Super ability for overload and short circuit, ensure the system stability and safety under the limit state of system


    Working Pricipal:


    MOdular UPS use double conversion on-line structure, including rectifier, inverter, battery charger, control circuit, the input and the output battery connector breaker. have function that is input power factor compensation. All modules can be online hot-swappable, providing the highest level of availability, and maintainability.
    If one power modular failure will not affect the system normal working, power module can be online hot-swappable all power module paralel is managed by the control board, in accourdance with the unified parameters running, one power module fault can be automatically exit parallel system, will not cause harm to the whole parallel system.

    Modular UPS system use independent static bepass module, do not use multiple static bypass structure, avoid caused overload damage modules because of multiple bypass module uneven current when UPS turn to bypass working. The module parallel output volage accuracy is ±1%, parallel circulation current<1%.

    Static bypass module contains bypass static switch only, excluded static switch of the amain circuit output; therefore, replacing static bypass modulewill not cause the system power down or transfer manual maintenance bypass, which can realize online hot-swap replacement.


    High Availability Configuration Structure


    Static switch module:


    ■ System standard configuration module

    ■ Adopts SCR and AC contactor in parallel

    ■ High reliability, strong overload ability: 1000% for 1 min

    ■ Transfer time less than 1ms

    ■ Have strong self-test, inter-lock and full-protection function


    Power Module:


    ■ Freedom choice of capacity configuration according demand, easy to expand

    ■ Online double-conversion design to ensure the output quality

    ■ Each module has independent digital intelligent control

    ■ Each module can work independently

    ■ Each module has a separate charging system

    ■ All modules can be hot-swappable, easy for online maintenance

    ■ Each UPS module provide 4.5KW charge capacity, equivalent to 10 to 12A



    Rich Management Interface


    Advanced battery management

    ■ All floating automatic conversion

    ■ Temperature compensation

    ■ Discharge to suspend automatic voltage regulation

    ■ Battery self-diagnosis and self-inspection

    ■ Battery capacity prediction

    ■ Discharge time estimates

    ■ Low voltage forecasting warning


    Data recorder


    Every 10 ms records a core electrical data, and in Fault occurs, the freezing failure 1 to 1.5 before work. The core of the cycle frequency electrical data Accurately record the cause of failure, to help the accident diagnosis and accurate positioning Rapid diagnosis to improve maintainability, the data will be recorded before a failure or overload occur.


    Advanced self-diagnosis


    ■ Inverter and rectifier circuit working condition monitoring

    ■ Battery capacity and status detection

    ■ Equipment working environment temperature testing

    ■ Ease of maintenance and management of equipment

    ■ Can each fan of fault detection, and replace the fan without power


    System
    Frequency50Hz/60Hz (Settable)
    Mains Synchronization Range±2Hz(Default value), adjustable with step of 0.5Hz within range of +/- 0.5Hz - 3Hz
    Protection LevelIP20
    Communication PortsRS232,RS485,dry contact, SNMP card, EPO, generator port
    System efficiency>96% at load above 50%, >95% at load above 25%
    Operation Temperature0-40ºC
    Storage Temperature-25ºC~70ºC ( without battery)
    Humidity0-95% (no-condensing)
    Noise(dB)55-62dB,Adjusted with load
    Weightmodule:PM2020KVA power module : 35KG
    module:PM3030KVA power module : 35KG
    module:PM4040KVA power module : 40KG
    Dimension (W x D x H)mm3 module cabinet600X900X1135
    5 module cabinet(5 battery cabinet option)600X1100X2070/
    6 module cabinet600X900X1535
    10 module cabinet900X900X2080
    power module440X650X132(3U)(10KVA/20KVA/30KVA)


    Technical Specifications:


    ModelCNM330 20-300KVA
    Capacity20-300KVA
    Main Input
    Input Voltage380V/400V/415V
    Input Frequency Range50/60Hz
    Power FactorFull load>0.99 ,Half load >0.98
    THDiTHDi<3%
    Input Power Soft-start Function5-30s settable
    Input Voltage Ranges228V-476V;-20%~25% at Full load ; linear derating at -25% ~- 40%; can take 70% load at -40%
    Frequency Range40-70HZ
    Battery
    Battery Voltage±240VDC(Default),12V Battery 30~40pcs can be choose
    Charge Voltage Accuracy±1%
    Bypass
    Bypass Input Voltage380/400/415VAC 3-phase 4-wire
    Voltage RangeDefault value is -20%~+15%; -40%, -30%, -10% ~ +10%, +15% , other ranges can be set via software
    Overload CapacityLong term at 135% rated load ,150%<load<180% more than 10 min,
    load>1000% 100ms
    Output
    Inverter Output Voltage380/400/415VAC 3-phase 4-wire
    Voltage Accuracy±0.5% ( balanced load ) , ±1% ( unbalanced load )
    THDVTHDV<1% (linear load) , THDV<3% (nonlinear load)
    Power Factor0.9
    Three Phase Angle Accuracy120°± 0.5°
    Current Crest Ratio3:1
    Overload Capacity110%1h,125%10mins,150%1mins,>150%200ms
    Transfer Time0ms,15ms (Eco Mode)

    (Optional South America 208V must be derating use)

    Buy 30 - 1200KVA Online Three Phase Ups Systems , Parallel Redundant Ups System High Efficiency at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Consnant Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0